12.07.2015 Views

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ground Fault ProductsHard Wired 30 Ampere GFCICircuit Guard Hard Wired 30A GFCI - UL Type 4X RatedDescription Voltage Alarm Manual Set Automatic SetHard wired, manual set 120V AC None GFHW13005 GFHW13105and automatic set GFCIs. 120V AC Audible GFHW13015 GFHW13115240V AC None GFHW23005 GFHW23105240V AC Audible GFHW23015 GFHW23115120/240V AC Audible GFHW33015 GFHW331153Ø250V AC None GFHW530 GFHW5313Ø120/208V AC None GFHW430 GFHW431Note: All units above are stock items.Build Your Own Catalog NumberCatalog Number Configurator:Example: Catalog Number: GFHW23015GF HW 2 3 0 1 5Voltage Amperage Reset Type Output Signal Mounting StyleGround Hard- 1-120 V AC 3 - 30 Amp 0 - Manual 0 - none 5 - Panel Mount/Fault Wired 2- 240 V AC 1 - Automatic 1 - Audible Alarm Surface Mount3-120/240V AC2 - Line Voltage4-3Ø120/208V AC3 - 24 Volt DC5-3Ø250V AC4 - 12 Volt DCNote: 2 to 3 week lead time for all “build your own” catalog numbers.SpecificationsElectrical RatingsRated Voltage120V AC, 240V AC and 120/240V, 3Ø 250V AC,3Ø 120/208V AC.Operating Voltage Range 85% to 110%.CurrentUp to 30A or device rating.Frequency60 Hz.Trip Level4-6 mA.PhaseSingle.Response Time.025 sec. Max.Dielectric Withstand 1500 VRMS across contact, 4000 VRMSbetween conductors and enclosure.Surge Withstand6000V impulse,0.5 microseconds rise time100 kHz ringing frequency with 40% decay per cycle.Let go line voltage60% of rated.Grounded neutral detection 6 Ohms or less.Power upManual or automatic reset.Environmental RatingsHousing Rating UL Type 4X.ConstructionIndustrial grade design.TypeClass A GFCI.Operating Temperature -35°C to +66°C, -30°F to +150°F.Leakage current@ 93% humidityZero.FeaturesLife (Endurance)10,000 cycles (6000 w/ load & 4000 w/o load).Open neutral protection Trips upon loss of neutral.Grounded neutral protection Trips if ground and neutral touch at load side.Power on indicatorGreen light on.Power off indicatorRed blinking light plus optional audible alarm.<strong>Wiring</strong> application3 Wire Single Phase (Hot, Neutral and Ground),4 Wire Single Phase (Line 1, Line 2, Neutral and Ground).Switch interfaceDouble Insulated.Latching Mechanism Electromagnetic.Physical SpecificationsWire LeadsUnit ColorLabel color on portable andWeight#10 AWG, 24" long.Gray with black cover.Automatic reset: yellow background w/ black hardwired units lettering. Manual reset: black backgroundw/ yellow lettering.1.40 lbs.Automatic Reset GFCIManual Reset GFCIDimensional DrawingGround Fault Products Hard Wired 30 Ampere GFCIDimensions in Inches (mm)www.hubbell-wiring.comH-17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!