12.07.2015 Views

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GFCI Sensing Module – 50A Maximum Rating Ground Fault ProductsGround Fault ProductsGFCI Sensing Module – 50A Maximum RatingThe sensing module functions interdependently with amagnetic branch circuit breaker. The module monitors theelectrical circuit by use of an external differential currenttransformer. No direct load is present at the module. In theevent of a ground fault, the load is interrupted by way of thehydraulic magnetic circuit breaker utilizing a shunt trip coil.This line of Sensing Modules is rated from 1 to 50 Ampsand circuit current-carrying conductors from 1 to 3 poles.Product is available with an automatic or manual “safestart” reset feature. The enclosure, when mounted with thesupplied gasket, achieves a UL NEMA 4X Rating.This module and breaker system is ideal for portablegenerator integration protecting all outlets on a generator.This system meets the proposed requirements forgenerators Underwriters Laboratory Standard 2201.UL/cUL 943 Listed, Class A 4-6mA trip level and UL 1053 Compliant.Typical Applications Include:Power Generators, Spas, High Pressure Washers, Power Centers, Refineries and Agricultural Equipment.GFSM120MGFSMCB120401P<strong>Wiring</strong> SchematicsHNCurrent carrying leads mustbe twisted as they go throughthe sensing module.120 VAC INPART #AUTO GFSM120AMAUUAL GFSM120M120VAC GFCISENSINGMODULECIRCUITBREAKERLOADLINEWHITEBLACKYELLOW (SHUNT)SINGLE PHASE 120VAC (HOT, NEUTRAL, GRND)GROUNDGFCI Sensing Module – 50A MaximumDescription120V AC Sensing Module Auto120V AC Sensing Module Manual240V AC Sensing Module Auto240V AC Sensing Module ManualGFCI Sensing Module Circuit BreakersCatalog Number Configurator -Example Catalog Number: GFSMCB120401PGFSMCB 120 40 1PGround FaultSensing ModuleCircuit Breaker120 Volt240 Volt120/240 VoltOther Examples:GFSMCB240502P: 240V 50A 2PGFSMCB240203P: 240V 20A 3PGFSMCB120XX1PNOCORANGESHUNTJUMPERHLOAD--->NGL1L2Current carrying leads mustbe twisted as they go throughthe sensing module.240 VAC INPART #AUTO GFSM240AMAUUAL GFSM240M240VAC GFCISENSINGMODULELOADLINE1 thru 50AmpCIRCUITBREAKERREDBLACKYELLOW (SHUNT)SINGLE PHASE 240VAC (L1, L2, GRND)GROUND1P2P3PGFSMCB240XX2PNOCORANGESHUNTJUMPERL1L2LOAD--->GL2L1N120/240VAC INCurrent carrying leads mustbe twisted as they go throughthe sensing module.Catalog NumbersGFSM120AGFSM120MGFSM240AGFSM240MLOADLINEWHITEBLACKYELLOW (SHUNT)SPLIT PHASE 120/240VAC (L1, L2, N, GRND)GROUNDPART #AUTO GFSM120AMAUUAL GFSM120M120VAC GFCISENSINGMODULECIRCUITBREAKERGFSMCB120XX2PNOCORANGESHUNTJUMPERL2L1LOAD--->NGH-10 www.hubbell-wiring.comDimensions in Inches (mm)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!