12.07.2015 Views

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

H-MOSS ® Occupancy Sensors<strong>Wiring</strong> SchematicsCeiling and Wall Mount SensorsAdaptive Dual <strong>Technology</strong>, Ultrasonic, and Passive Infrared Ceiling and Wall Mount SensorsATD, ATU and ATP Series Ceiling and Wall Mount SensorsSingle Circuit Application:1 to 3 sensors wired to control unit with optionaloverride off switch.NHBlackWhiteRedRedCU Series Control Unit(Specify Voltage)Switch*Lighting Load* Optional Override Off SwitchCircuit 1N HBlackWhiteCircuit 2N HRedRedRedRedLighting LoadLighting LoadRedBlackBlueCU Series Control Unit(Specify Voltage)AAR Add-A-RelayRedBlackBlueRedBlackBlueBlueBlkRedBlueBlkRedBlueBlkRedATD, ATU and ATP Series Sensors**Two Circuit Application:1 to 2 sensors wired to control unit and Add-A-Relay(control unit switches circuit 1, Add-A-Relay switchescircuit 2).BlueBlkRedBlueBlkRedATD, ATU and ATP Series Sensors****Note: For wiring sensors with isolated relay and photocell option(models with “RP” suffix): Photocell Option: Cap off Bluesensor wire. Connect Grey sensor wire to Blue controlunit wire. Isolated Relay Option: Common-Blue/White wire,Normally Closed-Black/White wire, Normally Open-Yellow/White wire.Single Circuit Application:Two control units wired in parallel to operate 4 to 6sensors in a single zone. Maximum 3 sensors percontrol unit any sensor will activate lighting.N HBlackWhiteRedRedRedWhiteBlackWhiteWhiteCU Series Control Unit(Specify Voltage)RedCircuit 1N HBlackWhiteRedRedCircuit 2N HBlackLighting LoadCU Series Control Unit(Specify Voltage)WhiteWhiteLighting LoadRed (+24V)BlackBlueBlueRed (+24V)BlackBlueCU Series Control Unit(Specify Voltage)Lighting LoadCU Series Control Unit(Specify Voltage)Lighting LoadRed (+24V)BlackBlueBlueRed (+24V)BlackBlueBlueBlkRedBlueBlkRedATD, ATU and ATP Series Sensors**BlackBlueBlkRedBlueBlkRedBlueBlkRedTwo Circuit Application:Two control units wired in two circuits to operate 3 to 6sensors in a single zone. Maximum 3 sensors per controlunit any sensor will activate both lighting loads.RedRedWhiteBlueBlkRedATD, ATU and ATP Series Sensors**BlackBlueBlkRedBlueBlkRedH-MOSS ® Occupancy Sensors <strong>Wiring</strong> Schematicswww.hubbell-wiring.comD-19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!