12.07.2015 Views

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

Hubbell Wiring Device.pdf - Eversave Technology

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ceiling Sensors with Adaptive <strong>Technology</strong> H-MOSS ® Occupancy SensorsH-MOSS ® Occupancy SensorsCeiling SensorsFeaturing Adaptive <strong>Technology</strong>ATD2000CRPATD2000CATD1000CRPATD1000CATD500CRPATD500CATU2000CRPATU2000CATU1000CRPATU1000CATU500CRPATU500CAll H-MOSS ceiling sensors with Adaptive <strong>Technology</strong>, contain the followingstandard features:• Adaptive technology – “Install and forget” operation• All digital sensing technology• Photocell for daylight harvesting and relay tointerface with auxiliary systems such as HVAC(RP models)Adaptive <strong>Technology</strong>, Dual (Ultrasonic and Passive Infrared)Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared (PIR)long-range major motion detection.Coverage Color Catalog Numbers2000 sq. ft. with photocell and isolated relay White ATD2000CRP2000 sq. ft. White ATD2000C1000 sq. ft. with photocell and isolated relay White ATD1000CRP1000 sq. ft. White ATD1000C500 sq. ft. with photocell and isolated relay White ATD500CRP500 sq. ft. White ATD500CNote: All ATD ceiling sensors must use a CU series control unit.Ultrasonic Major MotionUltrasonic Minor MotionPassive Infrared32'23'32'23'Ultrasonic Major MotionUltrasonic Minor Motion45'22'12'64'45'Adaptive <strong>Technology</strong>, Ultrasonic64'ATD2000CRP, ATD2000C32'23'• Non-volatile memory – Learned and adjustedsettings retained after power outage• 24V DC, 33mA• 32kHz (ATD/ATU500C & CRP - 40kHz)• Mounting base included with sensor23'32'32'23'16'22'12'23'32'ATD1000CRP, ATD1000CExcellent minor motion detection.Coverage Color Catalog Numbers2000 sq. ft. with photocell and isolated relay White ATU2000CRP2000 sq. ft. White ATU2000C1000 sq. ft. with photocell and isolated relay White ATU1000CRP1000 sq. ft. White ATU1000C500 sq. ft. with photocell and isolated relay White ATU500CRP500 sq. ft. White ATU500CNote: All ATU ceiling sensors must use a CU series control unit.ATU2000CRP, ATU2000C ATU1000CRP, ATU1000C ATU2000CRP, ATU2000CHallway Application56'D-12 www.hubbell-wiring.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!