Hubbell Wiring Device.pdf - Eversave Technology
Hubbell Wiring Device.pdf - Eversave Technology Hubbell Wiring Device.pdf - Eversave Technology
50 Ampere Twist-Lock Accessories Twist-Lock ® DevicesTwist-Lock ® Devices50 Ampere Twist-Lock AccessoriesHBL7774WOHBL7770HBL7382HBL50SCSS750Weatherproof Receptacle Lift Cover Plates for FS/FD Box MountingDescriptionCorrosion resistant, gray thermoplastic.Same as above except yellow.Cast aluminum.Note: See section K for more information on weatherproof plates.Receptacle Plates for FS/FD Box MountingDescriptionCast aluminum with lift cover.Same as above less lift cover.Stainless steel plate.Receptacle Box CoverDescriptionGalvanized Steel fits 4" square or 2-gang boxStainless steel wall plate.Weatherproof BootsDescriptionSeal-Tite ® triple seal black elastomeric cover for plugs when usedin a cord set and connector bodies when used with flanged inlets.Seal-Tite triple seal black elastomeric cover for connector bodieswhen used with cord sets.Closure CoverDescriptionBlack closure plug.Replacement PartsDescriptionCord clamp Kit.HBL7716C HBL7717C HBL4892IP44SUITABILITYIP55**SUITABILITYHBLCSCKCatalog NumbersHBL7774WOHBL77CM74WOHBL7770Catalog NumbersHBL7382•*HBL7383•SS750Catalog NumbersHBL50SCSS750Catalog NumbersHBL7716C**HBL7717C†Catalog NumbersHBL4892†Catalog NumbersHBLCSCKNotes: • Will only fit non-“CS” type 50A Twist-Lock receptacles.* Not UL Listed “WDL Closed”.** When installed and used properly with plug and connector body combinations.† Not UL Listed.B-60 www.hubbell-wiring.comDimensions in Inches (mm)
Hubbellock ® DevicesPlugs and Connector BodiesFeatures and BenefitsThree-piece thermoplastic clamp assembly with fast-lead stainlessscrews provides a more consistent durable grip. Grommets provide asealed cable entry that protects against the entry of moisture and dust.Superior wire terminations are assured with box terminals and screwswith pressure pads. This design captures stray wire strands and permitsmore clamping pressure on the wire without damaging it. Loosening ofterminations and resulting heat build-up are greatly reduced.Impact resistance in the interior of the female device comes from astrong thermoplastic material.No “lazy” connections because a spring-loaded safety shutterautomatically ejects the plug if it hasn’t been properly locked into thefemale device. This eliminates teasing of the contacts, a major causeof contact burn-up.Arcs are snuffed out, when devices are mated or unmated underload, by spring-loaded safety shutter.Longer contact life is assured by supplementary springs. Other devicesrely just on contacts themselves to provide proper contact pressure.Enhanced safety because access to live female contacts isrestricted by the spring-loaded safety shutter.Positive locking is ensured by the nose of the plug being keyed intoa detent in female device. This lock is independent of the contactsor a separate mechanical lock.Insulated non-metallic housing enhances safety and abuse resistance.Notes: Above cut-away view and call-outs are construction elements pertaining specifically to the 30A Hubbellock series.While the Hubbellock contact interface design applies to all, there are construction elements that are different,depending on the amperage.Hubbellock ® Devices Features and BenefitsDimensions in Inches (mm)www.hubbell-wiring.comB-61
- Page 79 and 80: Twist-Lock ® Devices15 Ampere, 125
- Page 81 and 82: Twist-Lock ® Devices15 Ampere, 125
- Page 83 and 84: Twist-Lock ® DevicesThe Standard f
- Page 85 and 86: Twist-Lock ® DevicesSafety-Shroud
- Page 87 and 88: Twist-Lock ® Devices20 Ampere, 250
- Page 89 and 90: Twist-Lock ® Devices20 Ampere, 125
- Page 91 and 92: Twist-Lock ® Devices20 Ampere, 125
- Page 93 and 94: Twist-Lock ® Devices20 Ampere, 3Ø
- Page 95 and 96: Twist-Lock ® Devices20 Ampere, 3Ø
- Page 97 and 98: Twist-Lock ® Devices30 Ampere, 125
- Page 99 and 100: Twist-Lock ® Devices30 Ampere, 125
- Page 101 and 102: Twist-Lock ® Devices30 Ampere, 3Ø
- Page 103 and 104: Twist-Lock ® Devices30 Ampere, 3Ø
- Page 105 and 106: Twist-Lock ® Devices30 Ampere, 480
- Page 107 and 108: Twist-Lock ® DevicesSwitched Safet
- Page 109 and 110: Twist-Lock ® DevicesMechanical Int
- Page 111 and 112: Non-NEMA Twist-Lock ® Devices10 Am
- Page 113 and 114: Non-NEMA Twist-Lock ® Devices20 Am
- Page 115 and 116: Non-NEMA Twist-Lock ® Devices30 Am
- Page 117 and 118: Non-NEMA Twist-Lock ® Devices30 Am
- Page 119 and 120: Twist-Lock ® DevicesAccessoriesfor
- Page 121 and 122: Twist-Lock ® DevicesAccessoriesfor
- Page 123 and 124: Twist-Lock ® DevicesAccessoriesfor
- Page 125 and 126: Twist-Lock ® Devices50 Ampere Plug
- Page 127 and 128: Twist-Lock ® Devices50 Ampere, 125
- Page 129: Twist-Lock ® Devices50 Ampere, 250
- Page 133 and 134: Hubbellock ® Devices20 Ampere, 125
- Page 135 and 136: Hubbellock ® Devices30 Ampere, 600
- Page 137 and 138: Hubbellock ® Devices60 Ampere, 600
- Page 139 and 140: Twist-Lock ® and Safety Shroud Dev
- Page 141 and 142: Twist-Lock ® DevicesTechnical Info
- Page 143 and 144: Switched Safety EnclosuresTechnical
- Page 145 and 146: Section CSwitchesSwitched Enclosure
- Page 147 and 148: SwitchesHBL ® Extra Heavy Duty Ind
- Page 149 and 150: Switches15, 20 and 30 Ampere, 120-2
- Page 151 and 152: Switches15 and 20 Ampere, 120-277 V
- Page 153 and 154: Switches15, 20 and 30 Ampere, 120-2
- Page 155 and 156: Switches600 to 1000 Watts, 120 Volt
- Page 157 and 158: SwitchesHeavy Duty Panel MountBat H
- Page 159 and 160: SwitchesPendant Pushbutton Station
- Page 161 and 162: AC SwitchesAccessoriesRed Neon Pilo
- Page 163 and 164: AC SwitchesAccessoriesNylon and Met
- Page 165 and 166: AC Switches40, 50, 60 and 85 Ampere
- Page 167 and 168: Disconnect SwitchesThermoplastic Co
- Page 169 and 170: AC SwitchesTechnical InformationHBL
- Page 171 and 172: AC SwitchesCertification ChartUL, C
- Page 173 and 174: AC SwitchesToggle Switch Wiring Dia
- Page 175 and 176: Switched EnclosuresCircuit-Lock ®
- Page 177 and 178: Switched EnclosuresCircuit-Lock ®
- Page 179 and 180: Switched EnclosuresCircuit-Lock ®
<strong>Hubbell</strong>ock ® <strong>Device</strong>sPlugs and Connector BodiesFeatures and BenefitsThree-piece thermoplastic clamp assembly with fast-lead stainlessscrews provides a more consistent durable grip. Grommets provide asealed cable entry that protects against the entry of moisture and dust.Superior wire terminations are assured with box terminals and screwswith pressure pads. This design captures stray wire strands and permitsmore clamping pressure on the wire without damaging it. Loosening ofterminations and resulting heat build-up are greatly reduced.Impact resistance in the interior of the female device comes from astrong thermoplastic material.No “lazy” connections because a spring-loaded safety shutterautomatically ejects the plug if it hasn’t been properly locked into thefemale device. This eliminates teasing of the contacts, a major causeof contact burn-up.Arcs are snuffed out, when devices are mated or unmated underload, by spring-loaded safety shutter.Longer contact life is assured by supplementary springs. Other devicesrely just on contacts themselves to provide proper contact pressure.Enhanced safety because access to live female contacts isrestricted by the spring-loaded safety shutter.Positive locking is ensured by the nose of the plug being keyed intoa detent in female device. This lock is independent of the contactsor a separate mechanical lock.Insulated non-metallic housing enhances safety and abuse resistance.Notes: Above cut-away view and call-outs are construction elements pertaining specifically to the 30A <strong>Hubbell</strong>ock series.While the <strong>Hubbell</strong>ock contact interface design applies to all, there are construction elements that are different,depending on the amperage.<strong>Hubbell</strong>ock ® <strong>Device</strong>s Features and BenefitsDimensions in Inches (mm)www.hubbell-wiring.comB-61