12.07.2015 Views

here - Saferoad RRS GmbH

here - Saferoad RRS GmbH

here - Saferoad RRS GmbH

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Stationary GuardrailsBridge ParapetsMobile BarriersCrash Cushions & TerminalsRoad Restraint Systems© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Traffic safety has noalternativeInnovative product families in allareas of road restraint systems.Mobility is key factor and challenge of our society. Thousandsof traffic deaths per year especially on country roads showthat t<strong>here</strong> is urgent need for action to improve our trafficinfrastructure.In many aspects <strong>Saferoad</strong> <strong>RRS</strong> considers itself as initiatorand trendsetter and takes up the cause of consequentlylooking for solutions to improve traffic safety significantly.Our MegaRail systems are based on a modular concept,which features only two, three or four standard elements.While the regular single-belt principle is implemented forsystems covering the lower containment level N2 and H1, thehigher containment levels H2 to H4b require a double-beltstructure which is capable of withstanding higher HGVs.Primus terminals can be flexibly adapted and protectselectively core accident areas. Plastically damping elementsand elastic deformation zones absorb the energy of impactand guide the decelerated vehicle away from the dangerzone. Passenger compartments remain undamaged.Our modern mobile barriers can be adjusted to theconditions on site and requirements without any problems.They function as a protective elastic band that, in the eventof a collision of a vehicle, develops restraining forces andguides the vehicle back onto the carriageway.2013-02


MegaRailPrimus2013-02


Guardrails » Stationary Guardrails » Single-sided GuardrailsSystemDrawingContainmentlevelWorkingwidthASIESP Plus W1 N2 W1 BMegaRailesN2 W2 AMegaRailec 2.2N2 W2 AMegaRaileN2 W3 BSuper Rail ES 1.0 N2 W3 A© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>2013-02


Guardrails » Stationary Guardrails » Single-sided GuardrailsSystemDrawingContainmentlevelWorkingwidthASIMegaRailslN2 W4 AMegaRailenN2 W4 AESP 2.0 (A) N2 W4 AESP Plus 2.0 N2 W4 APrimus 2a N2 W4 A2013-02© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary Guardrails » Single-sided GuardrailsSystemDrawingContainmentlevelWorkingwidthASIESP 2.0 (B) N2 W5 AESP 4.0 N2 W5 AESP 4.0 UFS N2 W5 ASuper Rail ES 1.0 H1 W2 AMegaRailec 3.3H1 W3 A© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>2013-02


Guardrails » Stationary Guardrails » Single-sided GuardrailsSystemDrawingContainmentlevelWorkingwidthASIMegaRailemH1 W4 AMegaRailslH1 W4 ASuper Rail ES 1.33 H1 W4 AEDSP 1.33 H1 W4 AEDSP 2.0 H1 W5 A2013-02© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary Guardrails » Single-sided GuardrailsSystemDrawingContainmentlevelWorkingwidthASIMegaRailbw asphaltH2 W3 BMegaRailsH2 W4 BMegaRailec 4.4H2 W4 ASuper Rail H2 W4 ASuper Rail Eco H2 W4 A© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>2013-02


Guardrails » Stationary Guardrails » Single-sided GuardrailsSystemDrawingContainmentlevelWorkingwidthASISuper Rail Eco MÜF H2 W4 AMegaRailekH2 W5 ASuper Rail light H2 W5 BSuper Rail H4b W7 A2013-02© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary Guardrails » Double-sided GuardrailsSystemDrawingContainmentlevelWorkingwidthASIDDSP 2.0++ H2 W6 ADDSP 1.33+SL H2 W7 AMegaRails twinH4b W7 BSuper Rail double H4b W4 B2013-02© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsSystemDrawingContainmentlevelWorkingwidthASIMegaRailbsH1 W2 AEDSP 1.33 Bw H1 W5 AMegaRailbwH2 W3 BSuper Rail Bw H2 W4 BSuper Rail Eco Bw H2 W4 B© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>2013-02


Guardrails » Bridge ParapetsSystemDrawingContainmentlevelWorkingwidthASISuper Rail light Bw H2 W4 BSuper Rail Plus Bw H4b W7 B2013-02© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Mobile BarriersSystemDrawingContainmentlevelWorkingwidthASIT1W3Limes3TSAT3W5T1W2Limes3T3T3 W4 AH2 W8 BT1W3Limes3BerlinAT3W6T1W1ProTec 120T3W2AH1W5© Limes Mobil <strong>GmbH</strong>2013-02


Guardrails » Stationary GuardrailsESP Plus W1N2 ∙ W1 ∙ BEU Certificate of Conformity: 0053-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.60W10.500.180.750.67rammed40.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailN2 ∙ W2 ∙ AesEU Certificate of Conformity: 2219-CPD-0004-2/dTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.80W20.700.210.702.00rammed60.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailN2 · W2 · Aec 2.2EU Certificate of Conformity: 2219-CPD-0004/gTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.80W20.700.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail ES 1.0N2 ∙ W2 ∙ AEU Certificate of Conformity: 0055-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.70W20.500.200.751.00rammed60.00.75 m0.20 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailN2 ∙ W3 ∙ BeEU Certificate of Conformity: 2219-CPD-0004-4/aTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.99W30.970.190.752.00rammed60.00.75 m0.19 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsESP BOSN2 ∙ W3 ∙ BEU Certificate of Conformity: 0038-CPD-2010TECHNICAL SPECIFICATIONSNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.90W30.200.860.75variablerammed20.0© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailN2 ∙ W4 ∙ AslEU Certificate of Conformity: 2219-CPD-0004-4/bTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.27W41.040.350.702.00rammed60.00.70 m0.35 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailN2 · W4 · AenEU Certificate of Conformity: 2219-CPD-0004/jTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.30W41.200.210.704.00rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsESP 2.0 (A)N2 ∙ W4 ∙ AEU Certificate of Conformity: 0760-CPD-F10052TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.30W41.300.180.752.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsESP Plus 2.0N2 ∙ W4 ∙ AEU Certificate of Conformity: 0024-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.20W41.100.180.752.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsPrimus 2aN2 · W4 · ATested in accordance with DIN EN 1317, BASt no.: 2002 7 D 05/RK ∙ 2002 7 D 06/RKTECHNICAL SPECIFICATIONSDRAWINGConstruction width (m) 1.10Construction height (m) 0.68Distance between posts (m)variableTested system foundation / installationrammedTest length (m) 6.431.10 m0.68 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsESP 2.0 (B)N2 ∙ W5 ∙ AEU Certificate of Conformity: 0760-CPD-F10053TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.60W41.600.180.752.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsESP 4.0N2 ∙ W5 ∙ AEU Certificate of Conformity: 0038-CPC-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.60W51.500.180.754.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsESP 4.0 UFSN2 ∙ W5 ∙ AEU Certificate of Conformity: 0760-CPD-F10055TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.70W51.600.180.754.00rammed60.00.75 m0.18 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH1 · W3 · Aec 3.3EU Certificate of Conformity: 2219-CPD-0004/hTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.90W30.700.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail ES 1.0H1 ∙ W3 ∙ AEU Certificate of Conformity: 0047-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.90W30.800.200.751.00rammed60.00.75 m0.20 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH1 ∙ W4 ∙ AemEU Certificate of Conformity: 2219-CPD-0035TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.30W41.200.210.702.00rammed44.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH1 · W4 · AslEU Certificate of Conformity: 2219-CPD-0004-4/bTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.25W41.090.350.702.00rammed60.00.70 m0.35 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail ES 1.33H1 ∙ W4 ∙ AEU Certificate of Conformity: 0081-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.10W40.900.200.751.33rammed60.00.75 m0.20 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsEDSP 1.33H1 ∙ W4 ∙ AEU Certificate of Conformity: 0760-CPD-F10057TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.20W40.900.500.751.33rammed60.00.75 m0.50 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsEDSP 2.0H1 ∙ W5 ∙ AEU Certificate of Conformity: 0760-CPD-F10056TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.60W51.300.500.752.00rammed60.00.75 m0.50 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W3 · Bbw asphaltEU Certificate of Conformity: 0016-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working width0.96W30.54 mNormalised dynamic defl ection (m)0.73Construction width (m)0.54Construction height (m)0.90Distance between posts (m)1.33Tested system foundation / installationTest length (m)anchored (asphalt)40.00.90 m0.67 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W4 · BsEU Certificate of Conformity: 0015-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.27Class of normalised working widthW40.49 mNormalised dynamic defl ection (m)0.97Construction width (m)0.49Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed60.00.90 m0.67 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W4 · Aec 4.4EU Certificate of Conformity: 2219-CPD-0004/fTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.10W41.000.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper RailH2 ∙ W4 ∙ AEU Certificate of Conformity: 0134-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working width1.30W40.50 mNormalised dynamic defl ection (m)0.80Construction width (m)0.50Construction height (m)1.15Distance between posts (m)1.33Tested system foundation / installationTest length (m)rammed40.01.15 m0.75 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail EcoH2 ∙ W4 ∙ BEU Certificate of Conformity: 0004-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.30Class of normalised working widthNormalised dynamic defl ection (m)W40.700.45 mConstruction width (m)0.45Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.00.90 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail Eco 1AH2 ∙ W4 ∙ AEU Certificate of Conformity: 0090-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working width1.30W40.45 mNormalised dynamic defl ection (m)1.10Construction width (m)0.45Construction height (m)1.00Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.01.00 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail Eco MÜFH2 ∙ W4 ∙ AEU Certificate of Conformity: 0157-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working width1.30W40.45 mNormalised dynamic defl ection (m)1.10Construction width (m)0.45Construction height (m)1.00Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed (asphalt)52.01.00 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W5 · AekEU Certificate of Conformity: 2219-CPD-0004/iTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.70W51.500.210.701.33rammed56.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail lightH2 ∙ W5 ∙ BEU Certificate of Conformity: 0091-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.50Class of normalised working widthNormalised dynamic defl ection (m)W51.000.45 mConstruction width (m)0.45Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.00.90 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper RailH4b ∙ W7 ∙ AEU Certificate of Conformity: 0165-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working width2.20W70.50 mNormalised dynamic defl ection (m)1.90Construction width (m)0.50Construction height (m)1.15Distance between posts (m)1.33Tested system foundation / installationTest length (m)rammed76.01.15 m0.75 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsDDSP 4.0H1 ∙ W6 ∙ AEU Certificate of Conformity: 0760-CPD-F10060TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.90W61.600.800.754.00rammed60.00.75 m0.80 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W4 · BdbEU Certificate of Conformity: 0017-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.25Class of normalised working widthW40.65 mNormalised dynamic defl ection (m)0.77Construction width (m)0.65Construction height (m)0.90Distance between posts (m)1.33Tested system foundation / installationTest length (m)rammed60.00.90 m0.60 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail doubleH2 ∙ W4 ∙ BEU Certificate of Conformity: 0099-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.20W40.650.861.151.33rammed60.01.15 m0.75 m0.86 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail Eco doubleH2 ∙ W4 ∙ BEU Certificate of Conformity: 0020-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.20Class of normalised working widthNormalised dynamic defl ection (m)W40.600.70 mConstruction width (m)0.70Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed52.00.90 m0.70 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH2 · W5 · AdEU Certificate of Conformity: 2219-CPD-0004-4/cTECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.66W51.360.790.752.00rammed60.00.75 m0.79 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsDDSP 2.0++H2 ∙ W6 ∙ AEU Certificate of Conformity: 0760-CPD-F10061TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)2.00W61.800.800.752.00rammed80.00.75 m0.80 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsDDSP 1.33+SLH2 ∙ W7 ∙ AEU Certificate of Conformity: 0099-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)2.30W71.500.800.751.33rammed64.00.75 m0.80 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsSuper Rail doubleH4b ∙ W5 ∙ BEU Certificate of Conformity: 0039-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.50W50.900.861.251.33rammed60.01.25 m0.75 m0.86 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Stationary GuardrailsMegaRailH4b · W7 · Bs twinEU Certificate of Conformity: 0018-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working width2.48W70.49 m1.00 mNormalised dynamic defl ection (m)1.50Construction width (m)1.98Construction height (m)0.90Distance between posts (m)2.00Tested system foundation / installationTest length (m)rammed68.00.90 m0.67 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsMegaRailH1 · W2 · AbsEU Certificate of Conformity: 0531-CPD-1317-0570TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)0.80W20.600.210.701.33anchored52.00.70 m0.21 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsEDSP 1.33 BwH1 ∙ W5 ∙ AEU Certificate of Conformity: 0760-CDP-F10058TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working widthNormalised dynamic defl ection (m)Construction width (m)Construction height (m)Distance between posts (m)Tested system foundation / installationTest length (m)1.60W51.200.500.651.33anchored68.00.65 m0.50 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsMegaRailH2 · W3 · BbwEU Certificate of Conformity: 0016-CPD-2011TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)Class of normalised working width0.98W30.54 mNormalised dynamic defl ection (m)0.73Construction width (m)0.54Construction height (m)0.90Distance between posts (m)1.33Tested system foundation / installationTest length (m)anchored40.00.90 m0.60 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsSuper Rail BwH2 ∙ W4 ∙ BEU Certificate of Conformity: 0015-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.30Class of normalised working widthW4Normalised dynamic defl ection (m)0.650.50 mConstruction width (m)0.50Construction height (m)1.05Distance between posts (m)1.33Tested system foundation / installationTest length (m)anchored36.01.05 m0.65 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsSuper Rail Eco BwH2 ∙ W4 ∙ AEU Certificate of Conformity: 0064-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.30Class of normalised working widthNormalised dynamic defl ection (m)W40.900.45 mConstruction width (m)0.45Construction height (m)0.80Distance between posts (m)1.33Tested system foundation / installationTest length (m)anchored60.00.80 m0.60 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsSuper Rail light BwH2 ∙ W4 ∙ BEU Certificate of Conformity: 0091-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)1.30Class of normalised working widthNormalised dynamic defl ection (m)W40.800.45 mConstruction width (m)0.45Construction height (m)0.80Distance between posts (m)1.33Tested system foundation / installationTest length (m)anchored36.00.80 m0.60 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Bridge ParapetsSuper Rail Plus BwH4b ∙ W7 ∙ BEU Certificate of Conformity: 0126-CPD-2010TECHNICAL SPECIFICATIONSDRAWINGNormalised working width (m)2.10Class of normalised working widthW70.60 mNormalised dynamic defl ection (m)1.31Construction width (m)0.60Construction height (m)1.15Distance between posts (m)1.33Tested system foundation / installationTest length (m)anchored80.01.15 m0.75 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Guardrails » Mobile BarriersLimes3TST1 ∙ W3 ∙ A / T3 ∙ W5 ∙ ATest in accordance with DIN EN 1317TüV-N o : X69.03.D01, X69.05.D02BASt-N o : 2006 7S 72/RK, 2005 7S 59/MWTECHNICAL SPECIFICATIONSDRAWINGConstruction length per day / 3 men (km) 2.00Elements per truck (m) 720System width (m) 0.45System height (m) 0.50Length of a single element (m) 12.0Test length (m) 72.0Weight (kg/m) 30.00.50 m0.15 m0.45 m© Limes Mobil <strong>GmbH</strong>


Guardrails » Mobile BarriersLimes3T3T1 ∙ W2 ∙ A / T3 ∙ W4 ∙ A / H2 ∙ W8 ∙ BTest in accordance with DIN EN 1317TüV-N o : X69.01.D01, X69.02.D01BASt-N o : 2005 7S 58/MW (T1 ∙ W2 / T3 ∙ W4)TECHNICAL SPECIFICATIONSDRAWINGConstruction length per day / 3 men (km) 1.80Elements per truck (m) 180 / 195System width (m) 0.50System height (m) 0.75Length of a single element (m) 12.0 / 13.0Test length (m) 108.0Weight (kg/m) 88.0 / 92.30.75 m0.35 m0.50 m© Limes Mobil <strong>GmbH</strong>


Guardrails » Mobile BarriersLimes3BerlinT1 ∙ W3 ∙ A / T3 ∙ W6 ∙ ATest in accordance with DIN EN 1317TüV-N o : 98 7 S 15/LU, 98 7 S 16/LUTECHNICAL SPECIFICATIONSDRAWINGConstruction length per day / 3 men (km) 2.00Elements per truck (m) 210System width (m) 0.50System height (m) 0.65Length of a single element (m) 12.35Test length (m) 97.2Weight (kg/m) 57.00.65 m0.50 m© Limes Mobil <strong>GmbH</strong>


Guardrails » Mobile BarriersProTec 120T1 ∙ W1 ∙ A / T3 ∙ W2 ∙ A / H1 ∙ W5 ∙ ATest in accordance with DIN EN 1317TüV-N o : X82.03.H06, X82.04.H06, X82.07.H09, X82.08.H09BASt-N o : 2007 7E 57, 2008 7E 54TECHNICAL SPECIFICATIONSDRAWINGConstruction length per day / 3 men (km) 1.80Elements per truck (m) 140System width (m) 0.30System height (m) 0.60Length of a single element (m) 10.0 / 5.00Test length (m) 120 / 150Weight (kg/m) 1630.60 m0.12 m0.30 m© Limes Mobil <strong>GmbH</strong>


Guardrails » Crash Cushions & TerminalsPrimus P2P2A · x1/y2 · Z2 · ATest in accordance with DIN EN 1317, TüV-N o : X.66.01.C09, X.66.02.C09TECHNICAL SPECIFICATIONSDRAWINGSystem width (m) 0.70System height (m) 0.65Tested system foundation / installationrammedTest length (m) 28.0 0.70 m0.65 m© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


Containment level Working width ASI SystemW1 B ESP Plus W1AMegaRail esW2A MegaRail ec 2.2A Super Rail ES 1.0BMegaRail eW3BESP BOSAMegaRail slN2AMegaRail enW4AESP 2.0 (A)A ESP Plus 2.0APrimus 2aAESP 2.0 (B)W5A ESP 4.0AESP 4.0 UFSA MegaRail ec 3.3W3A Super Rail ES 1.0AMegaRail emH1AMegaRail slW4A Super Rail ES 1.33A EDSP 1.33W5 A EDSP 2.0BSuper Rail VZBW3BMegaRail bw AsphaltBMegaRail sA MegaRail ec 4.4ASuper RailH2W4BSuper Rail EcoASuper Rail Eco 1AASuper Rail Eco MÜFAMegaRail ekW5BSuper Rail lightH4b W7 A Super RailSingle-sided GuardrailsH1 W6 A DDSP 4.0H2H4bBMegaRail dbW4BSuper Rail doubleBSuper Rail Eco doubleW5 A MegaRail dW6 A DDSP 2.0++W7 A DDSP 1.33+SLW5 B Super Rail doubleW7 B MegaRail s twinDouble-sided GuardrailsH1W2 A MegaRail bsW5 A EDSP 1.33 BwW3 B MegaRail bwBSuper Rail BwH2W4ASuper Rail Eco BwBSuper Rail light BwH4b W7 B Super Rail Plus BwBridge Parapets2013-02© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


KontaktContact informationDEUTSCHLANDGERMANYStationäre Schutzplanken / Bauwerkskonstruktionen / Anpralldämpfer & TerminalsStationary Guardrails / Bridge Parapets / Crash Cushions & Terminals<strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>Zentrale / Vertrieb DeutschlandHeadquarters / Sales GermanyBongard-und-Lind-Straße 156414 WerothT + 49 6435 90 80 0F + 49 6435 90 80 110weroth@saferoad-rrs.deMarko MaurerVertriebsleiter Deutschland/ProkuristHead of Sales Germany/Authorised SignatoryT + 49 6435 90 80 144F + 49 6435 90 80 310M + 49 160 535 12 10marko.maurer@saferoad-rrs.deTanja DiefenbachVertrieb/LogistikSales/LogisticsMark von FritschenProduktmanager TerminalsProduct Manager TerminalsT + 49 6435 90 80 132F + 49 6435 90 80 310tanja.diefenbach@saferoad-rrs.deT + 49 6435 90 80 415F + 49 6435 90 80 310M + 49 151 54 32 61 09mark.von-fritschen@saferoad-rrs.de<strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>Sales InternationalLandshuter Straße 110779 BerlinT + 49 30 21 24 91 11F + 49 30 21 24 91 50berlin@saferoad-rrs.deAngelo ZenoriniExportleiterSenior Export ManagerT + 49 30 21 24 91 200F + 49 30 21 24 91 50M + 49 151 19 55 05 45angelo.zenorini@saferoad-rrs.deMascha GodoltVertrieb/LogistikSales/LogisticsMandy DäumichenVertrieb/LogistikSales/LogisticsT + 49 30 21 24 91 205F + 49 30 21 85 00 9mascha.godolt@saferoad-rrs.deT + 49 30 21 24 91 202F + 49 30 21 85 00 9mandy.daeumichen@saferoad-rrs.dePOLANDROMANIATURKEY<strong>Saferoad</strong> <strong>RRS</strong> Polska Sp.zo.oGrzegorz BagińskiGeschäftsführerManaging Directorul. Marcinkowskiego 15088-100 InowrocławT + 48 52 35 40 225F + 48 52 35 40 229polska@saferoad-rrs.com<strong>Saferoad</strong> <strong>RRS</strong> Romania SRLAndrei PredescuGeschäftsführerManaging DirectorCalea Plevnei 46-48010233 BucurestiT + 40 21 319 19 12F + 40 21 319 19 62romania@saferoad-rrs.com<strong>Saferoad</strong> <strong>RRS</strong> Inşaat ve Yol GüvenliğiEkipmanları Tic. ve San. Ltd. Şti.Ender BülbülGeschäftsführerManaging DirectorBarbaros Mah. Sümbül Sok. No. 5Deluxia Palace Daire 15334746 Istanbul / AtaşehirT + 90 216 688 24 17F + 90 216 688 24 22turkey@saferoad-rrs.com© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>


KontaktContact informationMontageAssembly<strong>Saferoad</strong> Gräfenhainichen <strong>GmbH</strong><strong>Saferoad</strong> Senftenberg <strong>GmbH</strong>Dirk EinnatzGeschäftsführerManaging DirectorHartmut JohannesNiederlassungsleiter/ProkuristBranch Manager/Authorised SignatoryLeif MüllerGeschäftsführerManaging DirectorNiederlassung SchwerinKothendorfer Straße 119075 WarsowT + 49 38859 51 23F + 49 38859 51 24schwerin@saferoad-rrs.deJösigkstraße 306773 GräfenhainichenT + 49 34953 308 0F + 49 34953 308 388graefenhainichen@saferoad-rrs.deLaugkfeld 11/1301968 SenftenbergT + 49 35 73 37 30 0F + 49 35 73 37 30 30senftenberg@saferoad-rrs.comLimes mobil <strong>GmbH</strong> VerkehrssicherungMobile Schutzwände / VermietungMobile Barriers / Rental Services Kathrin KubenkVertrieb/LogistikLandshuter Straße 1Sales/Logistics10779 BerlinT + 49 30 21 24 91 11T + 49 30 21 24 91 204F + 49 30 21 24 91 50F + 49 30 21 85 00 9berlin@limes-mobil.dekathrin.kubenk@limes-mobil.deVerkehrssicherungTraffic AccommodationAußenstelle DorstenRudolf-Diesel-Straße 546282 DorstenT + 49 2362 950 49 0F + 49 2362 950 49 11dorsten@limes-mobil.deMichael TafelGeschäftsführerManaging DirectorT + 49 2369 20 95 260F + 49 2369 20 95 261michael.tafel@limes-mobil.deBrite-Line Europe <strong>GmbH</strong>FahrbahnmarkierungenTapesBongard-und-Lind-Straße 156410 WerothT + 49 6435 90 80 400F + 49 6435 90 80 410info@brite-line-europe.deSven HauskeVertriebsleiter/ProkuristHead of Sales/Authorised SignatoryT + 49 6435 90 80 411F + 49 6435 90 80 410M + 49 163 317 23 46sven.hauske@brite-line-europe.deBongard & LindNoise Protection <strong>GmbH</strong> & Co. KGLärmschutzNoise ProtectionBongard-und-Lind-Straße 156410 WerothT + 49 6435 90 80 0F + 49 6435 90 80 320info@bongard-lind.deGürbüz AcarVertriebsleiter/ProkuristHead of Sales/Authorised SignatoryT + 49 6435 90 80 172F + 49 6435 90 80 320M + 49 0178 434 73 25guerbuez.acar@bongard-lind.de© <strong>Saferoad</strong> <strong>RRS</strong> <strong>GmbH</strong>

Hooray! Your file is uploaded and ready to be published.