<strong>SR8</strong>-Plus Operation <strong>Manual</strong>73-100-810-I2 Introduction2.1 GeneralThe Hanson <strong>SR8</strong>-Plus Dissolution Test Station provides an entirely new approach todissolution testing by incorporating a user interface with built-in virtual instrumenttechnologies. These technologies provide a "smart" system that anticipates and reacts to theneeds of dissolution testing. The <strong>SR8</strong>-Plus incorporates the Hanson SR "Sustained Release"precision drive system and a high-performance maintenance free SR motor.The system can be configured with 6 or 8 vessels and can use both paddles and baskets.Many accessories are available for special sampling conditions, including small volumetesting with 150mL vessels, Transdermal Sandwich testing and ointment cells. Electronicsample probes (E-Probes) may be added to automate sample probe movement, and E-Probes may be connected to many types of autosamplers.By adding Hanson’s new digital temperature probes, the <strong>SR8</strong>-Plus can also monitor vesseltemperature by allowing automatic vessel temperature readings at programmed intervals.The digital temperature probes connect to the sampling probe and if accompanied by the E-Probe will move in and out of the vessel media and gather temperature data. (This data isprintable on the Hanson validation printer.)The <strong>SR8</strong>-Plus control panel includes Easy-Icon program controls and a LCD display withpop-up menus and convenient help screens. The control panel also provides five statuslights, quickly providing the user with instrument status information.To simplify dissolution testing and instill confidence that the test is performed correctly, the<strong>SR8</strong>-Plus allows the user to store 25 test protocols. These protocols contain test parametersincluding but not limited to the speed, temperature, sampling intervals, drug name, anddosage of the dissolution test. During testing, the <strong>SR8</strong>-Plus sends information to the optionalprinter (recommended). The subsequent printout includes a header with specific informationabout the operator, lab, sample, and a status report which provides a record of the motorspeed and waterbath temperature at designated intervals, as well as the high, low, andaverage at the end of the test. The <strong>SR8</strong>-Plus also includes programs for calibration,validation and diagnostics.The <strong>SR8</strong>-Plus has a built-in system of alerts and alarms, which are signaled by a soft chime,a pop-up window on the display, and status lights. These are programmed by the user andhave several functions: they can be used to remind the user to take a sample or change thepH; they alert the user to any error condition; and they remind the user to performmaintenance, such as changing the bath water, and calibration.Understanding that many labs work a single shift, the <strong>SR8</strong>-Plus can be programmed to turnoff the heater when the last test for the day is complete, then "wake-up" the next morning andturn the heater back on so that the waterbath is ready for the first test of the day. The <strong>SR8</strong>-Plus can also be controlled by an external computer. For a list of external commands,contact your local distributor or Hanson Research Corporation directly.Section 2 Introduction – 3 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!