<strong>SR8</strong>-Plus Operation <strong>Manual</strong>73-100-810-I4.5 Start UpCaution: The voltage indicated on the <strong>SR8</strong>-Plus Dissolution Test Station must be the sameas the power source. If the incorrect voltage is indicated, do not plug in the instrument.Contact Hanson Research.Achtung: Die angezeigte Spannung am <strong>SR8</strong>-Plus Dissolutionstester muβ die gleiche sein,wie die Netzpannung. Wird nicht die korrekte Netzspannung angezeigt, darf das Gerät nichtan das Netz angeschlossen werden, Wenden Sie sich bitte diesbezûglich sofort an die FirmaHanson Research.Attention: Le voltage indiqué sur le Système de Dissolution <strong>SR8</strong>-Plus doit être identique àcelui de la source de courant. Si le voltage diffère, ne pas brancher l’appareil avant deconsulter Hanson Research.Precaución: El Voltaje indicado en la Unidad de Disolución <strong>SR8</strong>-Plus debe ser el mismovoltaje del toma corriente. Por lo tanto si el voltaje es diferente, no conecte la unidad ynotifique a Hanson Research.1. Verify that the voltage indicated on the back of the controller is the same as the powersource.2. Plug the other end of the power cord into the grounded three-prong power outlet.NOTE: Power cord plug may need to be replaced for some countries’ power outletconfigurations. Ensure replacement plug is approved and properly rated for voltageand amperage.3. Turn on the power switch, located on the right hand side of the <strong>SR8</strong>-Plus Controller.4. The “Power On” status light on the front panel should illuminate. A title screen appearsfor 5 seconds and then the main screen is displayed.5. Turn the power switch off and un-plug the power cord from the grounded three-prongpower outlet.4.6 LevelingTools required:Level (not supplied) and small open end wrench (supplied in tool kit).For proper operation, the <strong>SR8</strong>-Plus Dissolution Test Station must be level. Most laboratorybenches are level, so minimal adjustment may be necessary.Each of the four feet on the <strong>SR8</strong>-Plus is adjustable. Place the level on the base plate asshown in Figure 4-8. Check the level, both left to right and front to back. If necessary, raiseany of the feet, using the open-end wrench, turning in a clockwise direction. Make sure allfeet are contacting the bench when finished.Section 4 Installation – 13 –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!