12.07.2015 Views

Schubert & Salzer 8049 Digital Positioner - RM Headlee

Schubert & Salzer 8049 Digital Positioner - RM Headlee

Schubert & Salzer 8049 Digital Positioner - RM Headlee

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Digital</strong> <strong>Positioner</strong><strong>8049</strong>Compact digital positioner for pneumatic control valves.• <strong>Positioner</strong> can be integrated into valve actuator (no externalmoving parts for stroke feedback)• Wide range of strokes .12 to 1.1 inches (3 - 28 mm)• No steady-state air consumption• Self-adapting to valve actuator• Configuration by PC-software• Not sensitive to vibrations• Protection class IP65• Available with AS-I control• Instrument air not required (filtration to 20µm)• Also available for the unse in Ex-Zone 22ATEX-Versions:II 2G Ex ia IIC T3/T4 for Type <strong>8049</strong>-ExII 1G Ex ia IIC T3/T4 for Type <strong>8049</strong>-Ex-0Technical Information, standard versionsVersion <strong>8049</strong>-4 <strong>8049</strong>-2 <strong>8049</strong>-AS-Inominal stroke 0,12 - 1,1 inch 0,12 - 1,1 inch 0,12 - 1,1 inchburden voltage 1,2 V 14 V (700 Ohm@20mA) -auxiliary energy, pneumatic 60 - 85 psi 65 - 85 psi 60 - 85 psiair delivery* linear drive 50 Nl/min. according the version 50 Nl/min.ambient temperature -4 to +167°F -14 to +167°F -14 to +167°Fcontrol signal 0/4 - 20 mA 4 - 20 mASingle Slave, Slave ProfilS - 7.3.4auxiliary energy, electric 24 VDC none supply with AS-Iadjustment of stroke and zero pointinternal air consumptionconfigurationmounting to control valvepressure supply portprotection class acc. DIN 40050self-learningnonewith PC-Softwarestandardized mounting kits (also with optical position indicator)G 1/8"IP 65


<strong>Digital</strong> <strong>Positioner</strong> <strong>8049</strong>Technical Information, ex-versionsVersion <strong>8049</strong>-Ex <strong>8049</strong>-Ex-0nominal stroke 0,12 - 1,1 inch 0,12 - 1,1 inchburden voltage 14 V (700 Ohm@20mA) 14 V (700 Ohm@20mA)auxiliary energy, pneumatic 65 - 85 psi 65 - 85 psiadjustment of stroke and zero pointinternal air consumptionconfigurationmounting to control valvepressure supply portprotection class acc. DIN 40050self-learningnonewith PC-Softwarestandardized mounting kits (also with optical position indicator)G 1/8"IP 65general information concerning explosion-proofingproduct type test certificate BVS 08 ATEX E154 BVS 08 ATEX E154ATEX specification II 2G Ex ia T3/T4 II 1G Ex ia T3/T4temperature rangesT4: Tamb = -10 … +104°FT3: Tamb = -10 … +167°FT4: Tamb = -10 … +104°FT3: Tamb = -10 … +167°Finformation concerning explosion-proofingmax. input voltage Ui = DC 30V Ui = DC 30Vmax. input current Ii = 100mA Ii = 100mAmax. input power Pi = 600mW Pi = 600mWmax. interior capacity Ci = insignificant Ci = insignificantmax. interior inductance Li = insignificant Li = insignificantMaterials<strong>Positioner</strong>housingGround plateVestamid (electroconductive)Aluminum, KTL-coated


<strong>Digital</strong> <strong>Positioner</strong> <strong>8049</strong>Measurements4,530,330,08 0,94APNPT1/8"1,93 4,762,2 2,56 2,6AccessoriesAnalogue feedback module <strong>RM</strong>-1• Linear feedback signal 4 - 20 mA• Independent from positioner electronics• Uses a separate potentiometer path• Easy to retrofit• 2 wire design• not appropriate for <strong>8049</strong>-Ex or <strong>8049</strong>-Ex-0Technical InformationSupply voltageOutput signal24V DC4 - 20 mATemperature range 32 - 122°F *Temperature coefficient< 0,2% / K* at temperatures outside this range, the feedback modulemust be readjusted at operating temperature.


<strong>Digital</strong> <strong>Positioner</strong> <strong>8049</strong>Basic designdig. positioner <strong>8049</strong>-4dig. positioner <strong>8049</strong>-2dig. positioner <strong>8049</strong>-Exdig. positioner <strong>8049</strong>-Ex-0dig. positioner <strong>8049</strong>-4 (version 5)quote only if required<strong>8049</strong>/ - - - S -4P12P1EP10P14P5For acutatorsingle acting 1double acting 2Air deliverylowstandardhighLSHBodyaluminium / plastic 0stainless steel ground plate 1body in stainless steel 2Electro-pneumatic connectioncable bushing 2 x M16x1,5 0NPT-thread 1/2" 1plug connection M12x1, 8-pin 2Pneumatic connectionG 1/8" 0NPT 1/8" 1Position measuringlinear potentiometer without sensing pinlinear potentiometer with standard sensing pin (L=3,92")linear potentiometer with curtated sensing pin (L=3,72")rotary potentiometer for semi-rotary driveEMV-galvanic separating module for exterior path sensor01G23Optical indicatorwithout indicatorindicator disc for sensing pin in PAindicator disc for sensing pin in metalrotation angle indicator0123Auxiliary modulewithout auxiliary moduleanalog feedback modul <strong>RM</strong>1intelligent feedback modul <strong>RM</strong>2 with two limiting value encodersIPC-process controllerASI012CAAccessorieswithout accessories 0gauge bloc single acting, scaling in bar and PSI 1Further detailsspecial design (quote only if required)positioner montage (ony for the manufacturer)SMSettingsstandard -settings on customer request 1Special designwithoutseparated version incl. xxterior path sensor for lift drivespecial design for ex zone 22 (dust)-12


<strong>Digital</strong> <strong>Positioner</strong> <strong>8049</strong>Configuration-Software - Setup-ParametersAdjustment of control parameters (input signal, stroke limitation, closing function,control hysteresis, valve function, etc.)Configuration-Software - Flow CharacteristicAdjustment of flow and display of various flow related functions.


<strong>Digital</strong> <strong>Positioner</strong> <strong>8049</strong>Configuration-Software - <strong>Positioner</strong> InformationInformation of valve stroke, running time, soft and hardware version, achieved temperature and strokelevels, error messages<strong>Positioner</strong> <strong>8049</strong> top mounted on GS-Control Valve Model 8021<strong>Positioner</strong> <strong>8049</strong> top mounted on AsepticRight Angle Control Valve Model 6021Text and pictures ate not binding. We reserve the right, to alter the equipment.Data sheet <strong>8049</strong>usa/Version: 04-06-2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!