Specification of Variants and Options140 MAINS SWITCH141* Rotary switch in accordance with the standard in section 3.2 andIEC 337-1, VDE 0113.142 Rotary switch according to 141 with door interlock.143 Flange disconnect in accordance with the standard in section 3.2. Includes doorinterlock.Additions to the mains switch:147/149 Circuit breaker for rotary switch. A 16 A (transformer 2 and 3) or 25 A (transformer 1)circuit breaker for short circuit protection of main cables in the cabinet. Circuitbreaker approved in accordance with IEC 898, VDE 0660.150 MAINS VOLTAGEThe robot can be connected to a rated voltage of between 200 V and 600 V, 3-phase andprotective earthing. A voltage fluctuation of +10% to -15% is permissible in eachconnection.151-174 Voltage Voltage Voltage200 V220 V400 V 400 V440 V 440 V475 V 475 V500 V 500 V525 V600 V175 MAINS FILTERThe mains filter reduces the emission of radio frequency on the incoming power, to levelsbelow requirements in the Machinery Directive 89/392/EEC. For installations in countriesnot affected by this directive, the filter can be excluded.177-179 Mains filter46 Product Specification IRB 1400 M98/BaseWare OS 3.1

Specification of Variants and Options180 OPERATOR’S PANELThe operator’s panel and teach pendant holder can be installed either181 Standard, i.e. on the front of the cabinet, or182 External, i.e. in a separate operator’s unit.All necessary cabling, including flange, connectors, sealing strips, screws, etc., issupplied.External enclosure is not supplied.M8 (x4)M4 (x4)19619322345 o External panel enclosureRequired depth 200 mm180 224 240706296Holes forflange(not supplied)140184200Holes foroperator’s panelTeach pendantconnectionHoles forteach pendant holder90Connection tothe controller5 (x2)155Figure 28 Required preparation of external panel enclosure (all dimensions in mm).Product Specification IRB 1400 M98/BaseWare OS 3.1 47

Specification of Variants <strong>and</strong> Options180 OPERATOR’S PANELThe operator’s panel <strong>and</strong> teach pendant holder can be installed either181 St<strong>and</strong>ard, i.e. on the front of the cabinet, or182 External, i.e. in a separate operator’s unit.All necessary cabling, including flange, connectors, sealing strips, screws, etc., issupplied.External enclosure is not supplied.M8 (x4)M4 (x4)19619322345 o External panel enclosureRequired depth 200 mm180 224 240706296Holes forflange(not supplied)140184200Holes foroperator’s panelTeach pendantconnectionHoles forteach pendant holder90Connection tothe controller5 (x2)155Figure 28 Required preparation of external panel enclosure (all dimensions in mm).Product Specification IRB 1400 M98/BaseWare OS 3.1 47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!