RepairsCalibration8. Press the function key All to select all axes, if all axes are to be calibrated.Otherwise, select the desired axis <strong>and</strong> press the function key Incl (the selected axisis marked with an x).9. Confirm your choice by pressing OK. The window shown in Figure 9 appears.Calibration!Robot- - - - - WARNING - - - - -The calibration for all marked axeswill be changed.It cannot be undone.OK to continue?CancelOKFigure 9 The dialog box used to start the calibration.10. Start the calibration by pressing OK.An alert box is displayed during the calibration.The Status window appears when the fine calibration is complete. The revolutioncounters are always updated at the same time as the calibration is performed.The robot is now roughly calibrated.11. Remove the protective plate from the reference surface on the manipulator base.12. Attach the calibration tool for axis 1 on the guide pin underneath the gearbox, seeFigure 10.Tool no.6808 0011-GRTool no.3HAB 1378-1Guide pin in gearboxFigure 10