Troubleshooting Tools3.4.7 CANX9Pin A C25 CANRLY2 N CANRLY3 N26 CAN_H CAN_LCANRLY2 N <strong>and</strong> CANRLY3 N respectively:0V when CAN 2 or CAN 3 is active (see <strong>Installation</strong> <strong>and</strong> <strong>Commissioning</strong>, section3.17.3).24V when CAN 2 <strong>and</strong> CAN 3 are disconnected (see <strong>Installation</strong> <strong>and</strong> <strong>Commissioning</strong>,section 3.17.3). In this case the backplane fixed termination resistor is connected in.3.4.8 SafetyX9Pin A C27 ENABLE9 SPEEDENABLE 9:5V when supply voltage is OK <strong>and</strong> the computers are OK (output from the robot computerto the panel unit; LED EN).SPEED:5V when one of the modes AUTO or MANUAL FULL SPEED is active (input to therobot computer from the panel unit).Product Manual 39