Troubleshooting Tools2.12 Profibus-DP, DSQC352PROFIBUS ACTIVENSMSCAN TxCAN RxPOWERX5X20ProfibusX3DSQC 352 ABB Flexible AutomationBus status LED’sProfibus activeNSMSCAN TxCAN RxPowerDesignation Colour Description/RemedyProfibus active Green Lit when the node is communicatingwiththe master. If no light, check systemmessages in robot <strong>and</strong> in Profibus net.NS/MS Green/red See section 2.14.CAN Tx/CAN Rx Green/red See section 2.14.POWER, 24 VDC Green Indicates that a supply voltage ispresent, <strong>and</strong> has a level above 12 VDC.If no light, check that voltage is presentin power unit.Check that power ispresent in the power connector. If not,check cables <strong>and</strong> connectors. If poweris available at the unit but the unit doesnot function, replace the unit24 Product Manual