Troubleshooting Tools1.1 TestsMost of the internal robot tests are only run when the robot is cold started. All the testscan be run in Monitor Mode 2, as described in Chapter 1.2. Non destructive memory tests,checksum tests, etc., are only run when the robot is warm started.Cold start tests in consecutive order.IOC = Robot computerAXC = Robot computerMC = Main computerAt every “power on”, the IOC makes a destructive RWM test. If it fails, the IOC will flashthe NS <strong>and</strong> MS front LEDs <strong>and</strong> stop the program running.# T1504: IOC Red LED off# T1005: IOC Memory test (RWM) Non Destructive# T1018: IOC Battery test# T1053: IOC IOC->AXC Access test# T1062: IOC IOC->AXC AM test# T1067: IOC IOC->AXC Memory test (RWM)# T1068: IOC IOC->AXC Memory test (RWM) R6 Global# T1069: IOC IOC->AXC Memory test (RWM) DSP# T1070: IOC Enable AXC->IOC Interrupts# T1061: IOC IOC->AXC Load AXC# T3001: AXC RWM test Dist.# T3002: AXC R6 Global RWM test# T3003: AXC DSP Double access RWM test# T3004: AXC DSP Data RWM test# T3020: AXC VME interrupt test# T3023: AXC Test channels output test# T1071: IOC Disable AXC->IOC Interrupts# T1046: IOC IOC->MC Access test# T1048: IOC IOC->MC AM testProduct Manual 5