<strong>Installation</strong> <strong>and</strong> <strong>Commissioning</strong>Connecting Signals3.16.7 Encoder interface unit, DSQC 354The encoder interface unit provides connections for 1 encoder <strong>and</strong> 1 digital input.The encoder is used for installation on a conveyor to enable robot programs to synchronizeto the motion (position) of the conveyor.The digital input is used for external start signal/ conveyor synchronization point.Further informationUser Reference Description Conveyor Tracking.For setup parameters, see User’s Guide, section System Parameters, Topic: Controller.Circuit diagram, see chapter 11.Customer terminals:X20Conveyor connectionDigin 2Enc 2BEnc 2ADigin 1Enc 1BEnc 1ACAN RxCAN TxMSNSPOWERX20EncoderDSQC 354 ABB Flexible AtomationX5X3X5-DeviceNet input<strong>and</strong> ID connectorX3Not to be usedDevice Net connector X5, see section 3.16.3 on page 51Figure 43 Encoder unit, DSQC 354Product Manual IRB 1400 63