About Omneon MediaGrid - Harmonic Inc
About Omneon MediaGrid - Harmonic Inc About Omneon MediaGrid - Harmonic Inc
System Installation with ContentServer 1000 and 2000 Series About File System Replication Factors For MediaGrid systems with the ContentServer 1000 and 2000 series, Harmonic recommends that you set the replication factor for your system at the default of 3 or, at minimum 2. Setting the replication factor to 1 means that no replication of the data in your file system will take place, and is not recommended. If the replication factor for your system is set to 1, in the case of system or disk failure (even one disk), your data will not be recoverable. For instructions on setting the replication factor, refer to Setting Replication Factors for File Systems in the Omneon SystemManager User Guide. About Site Preparation Note the following prerequisites for installation of your Omneon MediaGrid System. Preparing the Site Note the following prerequisites for installation of a Omneon MediaGrid storage system: • Environmental Omneon equipment is designed to operate in a clean, air-conditioned control room environment. Care must be taken to avoid temperature and humidity extremes. • Power When connecting equipment, care must be taken to avoid power lines that are subject to noise and voltage spikes. Do not install units on a power circuit that is common to such equipment as air conditioners and refrigeration units. For optimum protection, AC noise filters and surge protectors are recommended if unstable power conditions are present. • Site A full Omneon MediaGrid enclosure weighs approximately 1000 pounds (plus the weight of the enclosure rack). This weight is calculated as three ContentDirectors, two 1GbE switches, one 10GbE switch, one SystemManager and 30 ContentServers. Omneon MediaGrid equipment is designed for rack mounting. Refer to Rack Mounting an MediaGrid System with the ContentServer 1000 or 2000 Series for recommendations on how to mount the Omneon MediaGrid components. 60 Installation and Configuration Guide
Before You Begin System Installation with ContentServer 1000 and 2000 Series The following customer supplied components are required for this sample system setup. • One or more Desktop Clients (PCs). See the Omneon MediaGrid Release Notes for your particular client platform for the latest supported client operating systems. • A SystemManager platform including keyboard, monitor and mouse. The latest version of the SystemManager application should be installed on the SystemManager platform. See the Release Notes accompanying this release for the exact SystemManager application version required. See the Omneon SystemManager Installation Guide for more information. Shipping Container Components When you receive each component of a Omneon MediaGrid storage system, inspect each shipping container for signs of damage. Contact your local Omneon representative and the carrier immediately if you suspect any damage has occurred during shipping. Check the contents of each box against the packing list to ensure that all parts are included. If any items are missing, contact your local Omneon representative immediately. Cable and Mounting Hardware A rack mounting kit is provided with each Omneon MediaGrid component, which provides the items needed to mount each component on a rack. mounting instructions are also included. The type, quantity and length of the cables depends on the customer site and will likely differ for each separate installation. IMPORTANT: CX4 cables have a limit of 15 meters. The cables must be factory terminated and ordered in appropriate lengths to meet specifications. About Equipment Orientation Refer to the following sections to familiarize yourself with the connectors, displays, and indicators for the different MediaGrid hardware components before you interconnect the components in an Omneon MediaGrid system: • ContentDirectors 1000C/1000D and High Performance ContentDirector 2000 • ContentBridge 1000B • ContentBridge 2010B/2010C (High Bandwidth) • ContentServer 1042B • ContentServer 1042C-DP • ContentServer 2122 • ContentServer 2124 Omneon, Now Part of Harmonic 61
- Page 33 and 34: 1. From Windows, click the Start bu
- Page 35 and 36: 1. Add two registry parameters to t
- Page 37 and 38: CHAPTER 1 System Installation with
- Page 39 and 40: ContentBridge (optional) SystemMana
- Page 41 and 42: • Cluster names and device names
- Page 43 and 44: Public VLAN Private VLAN 1 Private
- Page 45 and 46: Public VLAN Private VLAN 1 Private
- Page 47 and 48: 16 5x(2+1)+1 500 GB 5 TB 16 5x(2+1)
- Page 49 and 50: System Installation with ContentSer
- Page 51 and 52: System Installation with ContentSer
- Page 53 and 54: System Installation with ContentSer
- Page 55 and 56: System Installation with ContentSer
- Page 57 and 58: Figure 10. ContentServer 3000 and 1
- Page 59 and 60: System Installation with ContentSer
- Page 61 and 62: System Installation with ContentSer
- Page 63 and 64: 10GbE Switch First Switch Second Sw
- Page 65 and 66: Module A To Client Network 10-GbE S
- Page 67 and 68: Connecting the ContentBridge System
- Page 69 and 70: Connecting the ContentDirectors Sys
- Page 71 and 72: Configuring a Stretch Cluster Syste
- Page 73 and 74: 10 GbE Module 1 GbE Module Public V
- Page 75 and 76: System Installation with ContentSer
- Page 77 and 78: CHAPTER 2 System Installation with
- Page 79 and 80: ContentBridge (optional) SystemMana
- Page 81 and 82: • The VLAN name and ID for the su
- Page 83: The following software installation
- Page 87 and 88: To rack mount an Omneon MediaGrid:
- Page 89 and 90: Figure 26. Rack Mounting the Conten
- Page 91 and 92: Installing the ContentServer Disk D
- Page 93 and 94: System Installation with ContentSer
- Page 95 and 96: 2 1 2 1 ID ID Figure 32. ContentSer
- Page 97 and 98: System Installation with ContentSer
- Page 99 and 100: System Installation with ContentSer
- Page 101 and 102: System Installation with ContentSer
- Page 103 and 104: 2. Continue connecting any remainin
- Page 105 and 106: System Installation with ContentSer
- Page 107 and 108: CHAPTER 3 System Configuration This
- Page 109 and 110: Password: OVN@SvCaUsa 3. Enter the
- Page 111 and 112: System Configuration 4. If you are
- Page 113 and 114: 6. Apply power to the ContentServer
- Page 115 and 116: Notes on Active Directory Configura
- Page 117 and 118: Follow the prompts to initialize th
- Page 119 and 120: Joining an Omneon MediaGrid Cluster
- Page 121 and 122: 1. From your SSH terminal, edit /et
- Page 123 and 124: A list of users in the domain displ
- Page 125 and 126: System Configuration 1. After confi
- Page 127 and 128: 4. Type the following commands to r
- Page 129 and 130: The expected result is: Domain=[SNV
- Page 131 and 132: System Configuration This mount poi
- Page 133 and 134: System Configuration c. Replace wi
Before You Begin<br />
System Installation with ContentServer 1000 and 2000 Series<br />
The following customer supplied components are required for this sample system setup.<br />
• One or more Desktop Clients (PCs). See the <strong>Omneon</strong> <strong>MediaGrid</strong> Release Notes for your particular<br />
client platform for the latest supported client operating systems.<br />
• A SystemManager platform including keyboard, monitor and mouse. The latest version of the<br />
SystemManager application should be installed on the SystemManager platform. See the Release<br />
Notes accompanying this release for the exact SystemManager application version required. See<br />
the <strong>Omneon</strong> SystemManager Installation Guide for more information.<br />
Shipping Container Components<br />
When you receive each component of a <strong>Omneon</strong> <strong>MediaGrid</strong> storage system, inspect each shipping<br />
container for signs of damage. Contact your local <strong>Omneon</strong> representative and the carrier immediately if<br />
you suspect any damage has occurred during shipping. Check the contents of each box against the<br />
packing list to ensure that all parts are included. If any items are missing, contact your local <strong>Omneon</strong><br />
representative immediately.<br />
Cable and Mounting Hardware<br />
A rack mounting kit is provided with each <strong>Omneon</strong> <strong>MediaGrid</strong> component, which provides the items<br />
needed to mount each component on a rack. mounting instructions are also included.<br />
The type, quantity and length of the cables depends on the customer site and will likely differ for each<br />
separate installation.<br />
IMPORTANT: CX4 cables have a limit of 15 meters. The cables must be factory terminated and ordered in<br />
appropriate lengths to meet specifications.<br />
<strong>About</strong> Equipment Orientation<br />
Refer to the following sections to familiarize yourself with the connectors, displays, and indicators for<br />
the different <strong>MediaGrid</strong> hardware components before you interconnect the components in an<br />
<strong>Omneon</strong> <strong>MediaGrid</strong> system:<br />
• ContentDirectors 1000C/1000D and High Performance ContentDirector 2000<br />
• ContentBridge 1000B<br />
• ContentBridge 2010B/2010C (High Bandwidth)<br />
• ContentServer 1042B<br />
• ContentServer 1042C-DP<br />
• ContentServer 2122<br />
• ContentServer 2124<br />
<strong>Omneon</strong>, Now Part of <strong>Harmonic</strong> 61