System Installation with ContentServer 3000 Series<br />

1. Complete these connections if one or more optional ContentBridges are part of the <strong>Omneon</strong><br />

<strong>MediaGrid</strong> system.<br />

a. Connect port 1 on the first ContentBridge to the first available port on switch module C.<br />

b. Connect port 0 on the first ContentBridge to the first available port on switch module D.<br />

2. Continue connecting any remaining ContentBridges in the same manner.<br />

Connecting Clients to the Network Switch<br />

To connect the clients:<br />

Connect the client computers to any of the ports on network switch module A only.<br />

Connecting the Power Cables<br />

With all of the network cable connections completed, connect the power cables as detailed in the<br />

following order.<br />

IMPORTANT: Do not turn on any equipment yet. Chapter 3, “System Configuration” includes<br />

instructions for powering on each <strong>Omneon</strong> <strong>MediaGrid</strong> device.<br />

To connect the power cables:<br />

1. The ContentServers 3000 and ContentStores 3160 have power switches on the front panel. Ensure<br />

that they are off. Do not plug the cords into power sources yet.<br />

2. The SystemManager has a Power connector on the back. Connect the power cable to the<br />

SystemManager power connector.<br />

3. The ContentBridges have a Power switch on the back. If part of the system, connect the power cable<br />

to the ContentBridge Power connector.<br />

4. The ContentDirectors have two power supplies. To take full advantage of the ContentDirector’s dual<br />

redundant power supplies, ensure that separate, isolated power sources are available. Connect the<br />

power cords to the ContentDirector’s two power connectors. Do not plug the cords into power sources<br />

yet.<br />

5. <strong>Harmonic</strong>-provided network switches do not have power switches — they power up when they are<br />

connected to a power source. Connect the power cords to the network switches’ power connectors.<br />

Do not plug the cords into power sources yet.<br />

Next Steps<br />

Refer to Chapter 3, “System Configuration” to set up the <strong>Omneon</strong> <strong>MediaGrid</strong> system’s devices<br />

using the customer-specific configuration information.<br />

46 Installation and Configuration Guide