System Installation with ContentServer 3000 Series Module A To Client Network 10-GbE SFP+ SFP+ Ports Ports 10-GbE SFP+ Ports Module C Module D 1 0 Figure 18. Omneon MediaGrid and 1 GbE Network Switch Connections FAULT REMOVE 2 3 0 1 44 Installation and Configuration Guide POWER 1 0 2 3 First ContentDirector First ContentServer 4 5 2 3 4 5 Gb 1 Gb 2 1 2 1 0 FAULT REMOVE SystemManager ContentBridge 1000B (Optional) POWER l 0 Module B

Connecting the ContentDirectors System Installation with ContentServer 3000 Series IMPORTANT: Ports 1-4 on switch modules C and D are reserved for ContentDirector private interface (ports 2 and 3) connections only. 1. To connect the ContentDirectors: Connect the ContentDirector private interfaces (ports 2 and 3) to the switch as follows: a. Connect port 2 on the first ContentDirector to port 1 on switch module D. b. Connect port 3 on the first ContentDirector to port 1 on switch module C. 2. Connect the ContentDirector public interfaces (ports 1 and 0) to the switch as follows: a. Connect port 1 on the first ContentDirector to port 5 on switch module C. b. Connect port 0 on the first ContentDirector to port 5 on switch module D. 3. Continue connecting any remaining ContentDirectors in the same manner, starting with port 2 on the switch for the private interfaces and port 6 on the switch for the public interfaces. Connecting the SystemManager To connect the SystemManager: Connect port 1 on the SystemManager to port 8 on switch module D. IMPORTANT: Make sure to leave a space for the SystemManager keyboard/monitor tray. It is recommended that you mount the keyboard monitor and tray 71.12 cm (28.0 in.) off the floor. This height is ideal for using the SystemManager while seated or standing. Connecting the ContentServers Complete these connections after connecting all ContentDirectors. To connect the ContentServers: 1. From the left-hand controller, connect NIC 0 to an open port on 1 GbE switch module C. This will serve as the BMC connection for this controller 2. From the left-hand controller, connect NICs 1, 2, 3, 4, and 5 to open ports on switch module C. 3. From the right-hand controller, connect NIC 0 to an open port on 1 GbE switch module D. This will serve as the BMC connection for this controller. 4. From the right-hand controller, connect NICs 1, 2, 3, 4, and 5 to open ports on switch module D. IMPORTANT: To ensure redundancy and proper failover in the event of a failure, you must connect each controller to a separate switch or switch module. 5. Continue connecting the remaining ContentServers in the same manner. Connecting the ContentBridge To connect the ContentBridge: Omneon, Now Part of Harmonic 45

System Installation with ContentServer 3000 Series<br />

Module A<br />

To Client Network<br />

10-GbE SFP+ SFP+ Ports Ports 10-GbE SFP+ Ports<br />

Module C Module D<br />

1<br />

0<br />

Figure 18. <strong>Omneon</strong> <strong>MediaGrid</strong> and 1 GbE Network Switch Connections<br />

FAULT<br />

REMOVE<br />

2 3<br />

0<br />

1<br />

44 Installation and Configuration Guide<br />

POWER<br />

1 0<br />

2 3<br />

First ContentDirector<br />

First ContentServer<br />

4 5 2 3 4 5<br />

Gb 1 Gb 2<br />

1<br />

2<br />

1<br />

0<br />

FAULT<br />

REMOVE<br />

SystemManager<br />

ContentBridge 1000B (Optional)<br />

POWER<br />

l<br />

0<br />

Module B