WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. These guidelines are provided to ensure your safety: • This unit should be mounted at the bottom of the rack if it is the only unit in the rack. • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with he heaviest component at the bottom of the rack. • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. ATTENTION : Pour éviter toute blessure corporelle pendant les opérations de montage ou de réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel. • Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas. • Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en plaçant l'élément le plus lourd dans le bas. • Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou de réparer l'unité en casier. WARNUNG: Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen: • Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden. • Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das Gestell von unten nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist. • Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die Stabilisatoren zu installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten. Specifications for the ContentServer 3000 and ContentStore 3160 Physical Dimensions: • Height: 5 in (13cm) • Width: 19 in (48.5 cm) • Depth: 26 in (66.5 cm) Power: AC Input rating: • Model CSS-3000: AC 100-240 V, 50/60 Hz, 10A • Model CSJ-3160: AC 100-240V, 50/60Hz, 5A Environmental Specifications: • Operating Temperature + 32 °F to + 95 °F, (0 °C to + 35 °C) xii Installation and Configuration Guide
• Storage Temperature -104 °F to +176 °F, (-40 °C to +80 °C) • Operating Humidity 5% to 95% non-condensing Weight: • Model CSS-3000: 75 Lb, 34 kg • Model CSJ-3160: 59.5 Lb, 27 kg Omneon, Now Part of Harmonic xiii
- Page 1 and 2: Omneon MediaGrid Installation and C
- Page 3 and 4: FCC Compliance This equipment has b
- Page 5 and 6: Parameter Specification Detail Safe
- Page 7 and 8: Parameter Specification Detail EMC
- Page 9 and 10: Network Switch 2924, 2948 and 5406
- Page 11: CAUTION: Danger of explosion if bat
- Page 15 and 16: Contents Introduction . . . . . . .
- Page 17 and 18: Contents Private VLANs . . . . . .
- Page 19 and 20: Contents Joining a ContentBridge 10
- Page 21 and 22: Contents About Access Control Lists
- Page 23 and 24: Contents Front Panel View . . . . .
- Page 25 and 26: Omneon MediaGrid Version 3.1.1 Intr
- Page 27 and 28: • Cluster, in the context of an O
- Page 29 and 30: Two models of ContentDirectors are
- Page 31 and 32: Keep in mind the following addition
- Page 33 and 34: 1. From Windows, click the Start bu
- Page 35 and 36: 1. Add two registry parameters to t
- Page 37 and 38: CHAPTER 1 System Installation with
- Page 39 and 40: ContentBridge (optional) SystemMana
- Page 41 and 42: • Cluster names and device names
- Page 43 and 44: Public VLAN Private VLAN 1 Private
- Page 45 and 46: Public VLAN Private VLAN 1 Private
- Page 47 and 48: 16 5x(2+1)+1 500 GB 5 TB 16 5x(2+1)
- Page 49 and 50: System Installation with ContentSer
- Page 51 and 52: System Installation with ContentSer
- Page 53 and 54: System Installation with ContentSer
- Page 55 and 56: System Installation with ContentSer
- Page 57 and 58: Figure 10. ContentServer 3000 and 1
- Page 59 and 60: System Installation with ContentSer
- Page 61 and 62: System Installation with ContentSer
WARNING: To prevent bodily injury when mounting or servicing this unit in a rack, you must<br />
take special precautions to ensure that the system remains stable. These guidelines are provided to<br />
ensure your safety:<br />
• This unit should be mounted at the bottom of the rack if it is the only unit in the rack.<br />
• When mounting this unit in a partially filled rack, load the rack from the bottom to the top with<br />
he heaviest component at the bottom of the rack.<br />
• If the rack is provided with stabilizing devices, install the stabilizers before mounting or<br />
servicing the unit in the rack.<br />
ATTENTION : Pour éviter toute blessure corporelle pendant les opérations de montage ou de<br />
réparation de cette unité en casier, il convient de prendre des précautions spéciales afin de maintenir<br />
la stabilité du système. Les directives ci-dessous sont destinées à assurer la protection du personnel.<br />
• Si cette unité constitue la seule unité montée en casier, elle doit être placée dans le bas.<br />
• Si cette unité est montée dans un casier partiellement rempli, charger le casier de bas en haut en<br />
plaçant l'élément le plus lourd dans le bas.<br />
• Si le casier est équipé de dispositifs stabilisateurs, installer les stabilisateurs avant de monter ou<br />
de réparer l'unité en casier.<br />
WARNUNG: Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit<br />
in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System<br />
stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen:<br />
• Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.<br />
• Bei Anbringung dieser Einheit in einem zum Teil gefüllten Gestell ist das Gestell von unten<br />
nach oben zu laden, wobei das schwerste Bauteil unten im Gestell anzubringen ist.<br />
• Wird das Gestell mit Stabilisierungszubehör geliefert, sind zuerst die Stabilisatoren zu<br />
installieren, bevor Sie die Einheit im Gestell anbringen oder sie warten.<br />
Specifications for the ContentServer 3000 and ContentStore 3160<br />
Physical Dimensions:<br />
• Height: 5 in (13cm)<br />
• Width: 19 in (48.5 cm)<br />
• Depth: 26 in (66.5 cm)<br />
Power:<br />
AC Input rating:<br />
• Model CSS-3000: AC 100-240 V, 50/60 Hz, 10A<br />
• Model CSJ-3160: AC 100-240V, 50/60Hz, 5A<br />
Environmental Specifications:<br />
• Operating Temperature + 32 °F to + 95 °F, (0 °C to + 35 °C)<br />