System Configuration<br />

You should see the following prompt:<br />

“Device may be rebooted, do you want to continue [y/n]?”<br />

8. Type “y”.<br />

You should see the following prompt:<br />

“Press ‘Enter’ and start xmodem on your host…”<br />

9. Press the Enter key.<br />

10. Select Send File from the Transfer menu on the HyperTerminal menu bar.<br />

A Send File window appears.<br />

11. Click the Browse button to locate the switch configuration files on the USB drive in one of the<br />

following directories: “configfiles/switches/HP3400” or “configfiles/switches/HP2900” or<br />

“configfiles/switches/HP5400” (depending on which switch you are configuring).<br />

12. Double-click the file “HP_subA1.cfg”, where is the switch model number (3400,<br />

2900).<br />

If you are configuring an HP5400 switch, select the configuration file for the type of connections, as<br />

follows:<br />

• For the all-1GbE port connections (regardless of the number of ports), use the<br />

HP5400_all_1G.cfg file<br />

• For the CX4 10GbE connections (both four and eight) on the top row of the switch, use the<br />

HP5400_CX4.cfg file<br />

• For the fiber 10GbE connections (both four and eight) on the top row of the switch, use the<br />

HP5400_MMF.cfg file<br />

NOTE: Contact <strong>Omneon</strong> Technical Support for configuration instructions if you are installing more than one<br />

HP5400 switch.<br />

13. Verify that Xmodem is selected as the transfer protocol.<br />

14. Click the Send button to send the file.<br />

The switch reboots and then closes the HyperTerminal connection.<br />

Configuring Switch B<br />

NOTE: If you are configuring an HP5400 switch, you can skip this section. The HP5400 combines switch A<br />

and switch B. Configuration was completed in the previous section.<br />

To configure switch B:<br />

1. Remove the serial cable from switch A.<br />

2. Connect the serial cable to switch B.<br />

3. Repeat the steps in Configuring Switch A above, using the file “HP_subB1.cfg” for Step<br />

12.<br />