2. Continue connecting any remaining ContentBridges in the same manner.<br />

Connecting to the Client Network<br />

System Installation with ContentServer 1000 and 2000 Series<br />

Depending on the type of client connection (CX4 or fiber optic), connect all module A cables on the<br />

network switch to the client network. If module B is used (for additional 10GbE connections to the<br />

client network), group the connections as shown in Figure 38.<br />

Connecting an <strong>Omneon</strong> <strong>MediaGrid</strong> System with a 5406 Network<br />

Switch (all 1GbE model)<br />

This section provides instructions for connecting an <strong>Omneon</strong> <strong>MediaGrid</strong> system using the all-1GbE<br />

5406 network switch, to which clients directly connect.<br />

In this configuration, the top module is reserved for client connections and the lower two modules are<br />

reserved for the <strong>Omneon</strong> <strong>MediaGrid</strong> subnet. Routing is enabled on the switch for connectivity<br />

between clients and <strong>Omneon</strong> <strong>MediaGrid</strong>.<br />

Refer to Figure 39 when connecting the system. Not all connections are shown. See the instructions<br />

following the illustration for each device’s specific port connections.<br />