APPENDIX A: Fire <strong>and</strong> Explosion Damage<br />
Table A-1 lists damage at the <strong>CTA</strong> facility as a result of the February 20, 2003, fire <strong>and</strong> dust explosions.<br />
The damage is broken down by specific plant area <strong>and</strong> likely cause.<br />
Table A-1<br />
Fire <strong>and</strong> Explosion Damage<br />
Location Damage Cause<br />
Line 405<br />
South of line<br />
405<br />
Between lines<br />
403 <strong>and</strong> 405<br />
Line 403<br />
Concrete block masonry firewall on<br />
east side partially collapsed <strong>and</strong><br />
pushed eastward<br />
Metal panels detached at south end of<br />
partially enclosed area above blend<br />
room deformed in southward direction<br />
Explosion overpressure originated in area<br />
between oven <strong>and</strong> wall <strong>and</strong> in partially enclosed<br />
area above blend room <strong>and</strong> below ceiling<br />
Higher explosion overpressure in partially<br />
enclosed area above blend room <strong>and</strong> below<br />
ceiling<br />
Damage to building roof above line Higher explosion overpressure inside plant in<br />
this area<br />
Ceiling panels <strong>and</strong> lights pushed<br />
downward<br />
Wall <strong>and</strong> polycarbonate panels of<br />
blend room deformed <strong>and</strong> pushed out<br />
in westward direction<br />
Combustible material inside curing<br />
oven burned away; metal conveyor<br />
burned clean <strong>and</strong> free of debris; no<br />
explosion damage observed inside<br />
oven<br />
Concrete block masonry firewalls<br />
surrounding room directly south of line<br />
<strong>and</strong> near raw material storage area<br />
permanently deformed<br />
Fire scorching in area where no<br />
masonry walls extend to ceiling;<br />
residual burnt resin material attached<br />
to open-web steel joists<br />
Concrete block masonry firewall in<br />
open bay between lines collapsed<br />
Metal panels above east wall of blend<br />
room pushed westward<br />
Oven exhaust line <strong>and</strong> thermal oxidizer<br />
inlet line separated<br />
Higher explosion overpressure in partially<br />
enclosed area above blend room<br />
Higher explosion overpressure inside blend<br />
room<br />
Burning of accumulated phenolic resins <strong>and</strong><br />
some chain oil inside oven<br />
Higher explosion overpressure in room south of<br />
line<br />
Path of fire traveled from production area into<br />
raw material storage area<br />
Damage consistent with large rebound<br />
movement of wall aided by wrap-around<br />
pressure<br />
Higher explosion overpressure east of line<br />
Higher explosion overpressure inside thermal<br />
oxidizer piping<br />
101