<strong>MULTIFUNCTION</strong> <strong>PROGRAMMABLE</strong> <strong>TIMER</strong>RCT602Non-volatile memory2-setpoint, dual display9 user selectable ranges10 milliseconds to 9999 hours4 user selectable relay functions3 user selectable modesIncrementing / decrementing display4 control inputsFixed/Configurable control inputs0.01% quartz crystal accuracySupply voltage : 85 ~ 265 V ACSPECIFICATIONSAll specifications at ambient of 25 C, unless specified otherwiseCAT#397R0/P1/4/300911/ARange See Table 1Resolution See Table 1Accuracy± 0.01% of reading ± 0.2 secondTiming start delay0.05 Sec (max)(after application of power)OUTPUTSNo. of relays 2Relay contacts1 x NO-C-NC (RL1)1 x NO-C (RL2)Relay contact rating5A / 230V AC, resistiveFunctions See Fig.1, 2Mutual isolation betweenInput/Output/Supply1500 V AC / 1 MinuteCONTROL INPUTSNo. of control inputs 4Control input functionconfigurationa) Fixedb) User configurableControl input functions See Table 2, 3Assignment of control inputfunctions to control inputs a) Fixed : See Table 2b) User configurable :i) Any control function can beassigned to any control inputii) One control function can beassigned to any one controlinput only (See Table 3)Front panel resetPOWER SUPPLYSupply voltageINDICATIONDisplayMEMORYWill have the same function asreset function selected for controlinput85~265 V AC / DC, 50 HzUpper : 4 digit, 7 segment 0.3”(7.6 mm) red LED displayLower : 4 digit, 7 segment 0.3”(7.6 mm) green LED displayNon volatile, indefinite retention(for elapsed time)<strong>PROGRAMMABLE</strong>PARAMETERSSetpoint 1 0.01 to 9999Setpoint 2 0.01 to 9999Timer StartPower ON, Control input 1(Start)(After timer start)Control input 1 Refer Table 3(For order code 2289-01)Control input 2 Refer Table 3(For order code 2289-01)Control input 3 Refer Table 3(For order code 2289-01)Control input 4 Refer Table 3(For order code 2289-01)UnitsSeconds / Minutes / HoursResolution 0.01, 0.1, 1Functionsa) ON delayb) OFF delayc) Cyclic C1(Relay ON at power ON)d) Cyclic C2(Relay OFF at power ON)(See Fig 1, 2)DirectionUp (incrementing)Down (decrementing)Mode Modes 0 ~ 2, See Fig 1 ~ 6Relay2*ON / OFFReset lockON, OFF(For front key reset)Program lockON, OFFOTHERKeyboardTactile, 3 keysEnclosure construction Plug-in (circuit removable withoutaffecting terminal wiring)Dimensions (in mm)48(H) x 48(W) x 100(D)MountingPanel mountPanel cutout44 x 44 mmoOperating ambient temperature 0~50 C* Available only when mode 0 is selected.TABLE 1 - RANGE SELECTIONUNITsssmmmhhhRANGE99.99 s999.9 s9999 s99 m 59 s999.9 m9999 m99 h 59 m999.9 h9999 hRESOLUTION0.01 s0.1 s1 s1 s0.1 m1 m1 m0.1 h1 hwww.radix.co.in/rct.htm


<strong>MULTIFUNCTION</strong> MEMORY <strong>TIMER</strong>RCT60212 TIMING FUNCTIONS, 4 FIXED/CONFIGURABLE CONTROL INPUTSOPERATING MODESt1 = SETPOINT1t2 = SETPOINT2RELAY ON RELAY OFF SUPPLY ON START PULSEMODE 0 - POWER ON STARTMODE 0 - START PULSERL1RL1RL1RL1RL2RL2t1t1t1 t2 t1t1 t2ON DELAYINTERVALCYCLIC C1CYCLIC C2= ON (Instant) *= OFF *STARTPULSERL1RL1RL1RL1RL2t1t1t1 t2 t1t1 t2ON DELAYINTERVALCYCLIC C1CYCLIC C2= ON (Instant) *RL2= OFF *FIG 1FIG 2MODE 1 - POWER ON STARTMODE 1 - START PULSERL1RL2RL1t1t2t1ON DELAYINTERVALSTARTPULSERL1RL2t1t2ON DELAYRL2RL1RL2RL1t2t1 t2 t1t1 t2t1 t2CYCLIC C1CYCLIC C2RL1RL2RL1RL2t1t2t1 t2 t1t1 t2INTERVALCYCLIC C1RL2t1 t2 t1RL1t1t2CYCLIC C2FIG 3RL2t1 t2 t1FIG 4MODE 2 - POWER ON STARTMODE 2 - START PULSERL1, RL2t1ON DELAYSTARTPULSERL1, RL2t2INTERVALRL1, RL2t1ON DELAYRL1, RL2t1 t2 t1CYCLIC C1RL1, RL2t2INTERVALRL1, RL2t1t2t1t2CYCLIC C2RL1, RL2t1 t2 t1CYCLIC C1FIG 5RL1, RL2t1t2t1CYCLIC C2t2FIG 6www.radix.co.in/rct.htmCAT#397R0/P2/4/300911/A


<strong>MULTIFUNCTION</strong> <strong>PROGRAMMABLE</strong> <strong>TIMER</strong>RCT602TABLE 2 - FIXED CONTROL INPUTS (ORDER CODE : 2289-00)CONTROL INPUTFUNCTIONDESCRIPTIONCONTROL INPUTFUNCTIONDESCRIPTION1StartStart the timer3GateFreeze the timer as long as input ispresent & relay maintain status.2ResetTimer is reset as long as input is present,timer starts when input is removed.4StopStop the timer & relay turn OFF.TABLE 3 - CONFIGURABLE CONTROL INPUTS (ORDER CODE : 2289-01)CONTROL INPUTFUNCTIONDESCRIPTIONCONTROL INPUTFUNCTIONDESCRIPTION1StartStart the timer6Gate2Freeze the timer as long as input is present& relay turn ON.2Reset1Timer is reset as long as input is present, timerstarts when input is removed.7Gate3Freeze the timer as long as input is present& relay turn OFF.3Reset2Pulse reset, reset the timer & start immediate.8Stop1Stop the timer & relay maintain status.4Reset3Reset the timer, start pulse is require to startthe timer.9Stop2Stop the timer & relay turn ON.5Gate1Freeze the timer as long as input ispresent & relay maintain status.10Stop3Stop the timer & relay turn OFF.CONNECTION DIAGRAMFIXED INPUTSCONFIGURABLE INPUTS85~265VRELAY1-AV S* - RCT602/RCT702 ONLY NC1 C1 NO1AC/DC5 4 3 2 1RELAY1-BRELAY2 *NO21113NO3C21214C310NC29 8 7 6GNDSTOPSTARTSTK-349ORDER CODE : 2289-0085~265VRELAY1-AV S* - RCT602/RCT702 ONLY NC1 C1 NO1AC/DC5 4 3 2 1RELAY1-BRELAY2 *1113NO2NO3C21214C310NC29 8 7 6GNDCIN2CIN1ORDER CODE : 2289-01STK-350ORDERING INFORMATIONORDER CODE2289AAControl InputsFixedConfigurable00011 00 1CAT#397R0/P3/4/300911/Awww.radix.co.in/rct.htm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!