<strong>PR</strong>etop<strong>5333</strong>B2-WIRE <strong>PR</strong>OGRAMMABLE TRANSMITTERRTD or Ohm inputHigh measurement accuracy3-wire connectionProgrammable sensor error valueFor DIN form B sensor head mountingApplication:• Linearised temperature measurement withPt100...Pt1000 or Ni100...Ni1000 sensor.• Conversion of linear resistance variation to astandard analogue current signal, for instancefrom valves or Ohmic level sensors.Technical characteristics:• Within a few seconds the user can program<strong>PR</strong><strong>5333</strong>B, C & D to measure temperatureswithin all RTD ranges defined by the norms.• The RTD and resistance inputs have cablecompensation for 3-wire connection.Mounting / installation:• For DIN form B sensor head mounting.• NB: As Ex barrier we recommend 5104B,5114B, or 5116B.RTD to 4...20 mA+ -Resistance to 4...20 mA+ -2-wire installationin control roomV+mA2-wire installationin control roomV+mALerbakken 10 · DK-8410 RøndeTlf. 8637 2677 · Fax 8637 3085www.prelectronics.dk


Order: <strong>5333</strong>Type<strong>5333</strong>VersionATEX: BFM and ATEX : CCSA, FM and ATEX : DConnections:Input:RTD, 2-wire RTD, 3-wire Resistance, 2-wire Resistance, 3-wire3 4 6 3 4 6 3 4 6 3 4 6Output:2-wire installation1 2+mA -Electrical specifications:Specifications range:-40°C to +85°CCommon specifications:Supply voltage, <strong>5333</strong>B ..................... 8.0...30 VDC<strong>5333</strong>C and D ........... 8.0...28 VDCInternal consumption ......................... 25 mW...0.8 WVoltage drop ...................................... 8 VDCWarm-up time .................................... 5 min.Communications interface ................ Loop LinkSignal / noise ratio ............................. Min. 60 dBResponse time (programmable) ........ 0.33...60 sSignal dynamics, input ...................... 19 bitSignal dynamics, output .................... 16 bitCalibration temperature ..................... 20...28°CAccuracy, the greater of general and basic values:Input typeGeneral valuesAbsoluteaccuracy<strong>Temperature</strong>coefficientAll ≤ ±0.1% of span ≤ ±0.01% of span / °CInput typeRTDLin. RBasic valuesBasicaccuracy≤ ±0.3°C≤ ±0.2 Ω<strong>Temperature</strong>coefficient≤ ±0.01°C / °C≤ ±20 mΩ / °CEMC immunity influence ........................... ≤ ±0.5% of spanEffect of supply voltage variation ...... ≤ 0.005% of span / VDCVibration ............................................ IEC 60068-2-6 Test FCLloyd’s specification no. 1 ................. 4 g / 2...100 HzMax. wire size .................................... 1 x 1.5 mm 2 stranded wireHumidity ............................................ < 95% RH (non-cond.)Dimensions ........................................ Ø 44 x 20.2 mmProtection degree (encl. / terminal) ... IP68 / IP00Weight ............................................... 50 gElectrical specifications, input:RTD and linear resistance input:RTDtypePt100Ni100Lin. RMin.value-200°C-60°C0 ΩMax.value+850°C+250°C10000 ΩMin.span25°C25°C30 ΩStandardIEC 60751DIN 43760-----Max. offset ......................................... 50% of selec. max. valueCable resistance per wire (max.) ....... 10 ΩSensor current ................................... > 0.2 mA, < 0.4 mAEffect of sensor cable resistance(3-wire) ............................................... < 0.002 Ω / ΩSensor error detection ....................... YesOutput:Current output:Signal range ...................................... 4...20 mAMin. signal range ............................... 16 mAUpdating time .................................... 135 msLoad resistance ................................. ≤ (V supply - 8) / 0.023 [Ω]Load stability ..................................... < ±0.01% of span/100 ΩSensor error detection:Programmable ................................... 3.5...23 mANamur NE43 Upscale ........................ 23 mANamur NE43 Downscale ................... 3.5 mAEEx / I.S. approval:KEMA 03ATEX1535 X ........................ II 1 GD, T80°C...T105°CEEx ia IIC T6 / T4Max. amb. temperature for T1...T4 ... 85°CMax. amb. temperature for T5 and T6 .. 60°CATEX, applicable in zone ................... 0, 1, 2, 20, 21 or 22Ex / I.S. data:Signal output / supply, terminal 1 to 2:U i ....................................................... : 30 VDCI i ......................................................... : 120 mADCP i ....................................................... : 0.84 WL i ........................................................ : 10 µHC i ....................................................... : 1.0 nFSensor input, terminal 3, 4 and 6:U o ...................................................... : 27 VDCI o ........................................................ : 7 mAP o ...................................................... : 45 mWL o ....................................................... : 35 mHC o ...................................................... : 90 nFFM, applicable in ............................... IS, Cl. I, Div. 1, Gr. A, B, C, DIS, Cl. I, Zone 0, AEx ia IICFM Installation Drawing No. ........ 5300Q502CSA, applicable in ............................. IS, Cl. I, Div. 1, Gr. A, B, C, DIS, Cl. I, Zone 0, Ex ia IICCSA Installation Drawing No. ...... 533XQC03Marine approval:Det Norske Veritas, Ships & Offshore .. Stand. for Certific. No. 2.4GOST R approval:VNIIFTRI, Cert No. ............................. Ross DK.GB06.V00100Ex Permit ........................................... РРС00-17800Observed authority requirements: Standard:EMC 2004/108/ECEmission and immunity ............. EN 61326ATEX 94/9/EC .................................... EN 50014, EN 50020,EN 50281-1-1 andEN 50284FM ..................................................... 3600, 3611, 3610CSA, CAN / CSA ............................... C22.2 No. 157,E60079-11, UL 913Of span = Of the presently selected range<strong>5333</strong>BY109-UK (0820)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!