ALFÉA EXTENSAAIR TO WATER HEAT PUMP• Six models: 5 to 16 kW single phase• COP (coeffi cient of performance) up to 4.5• Suitable for new build and renovationIndoor hydraulic moduleOutdoor inverter unit


Alféa ExtensaA LOW TEMPERATURE SOLUTION FOR TAILOR MADE APPLICATIONSLOW TEMPERATURE SOLUTION FOR TAILOR-MADE APPLICATIONSCOP to 4.5, Class A low consumption circulating pump, optional 1 or 2 zone(s) management, domestic hotwater production, cooling option; Alféa Extensa is the all-round low temperature solution in the Alféa range.Very easily adaptable and highly performant, its design and option range make it a benchmark in the heating sector!PERFORMANCE COEFFICIENT (COP)COP is an indicator of the heat pump performance. It correspondsto the difference between the amount of heat generated by the heatpump and the energy consumed for the equipment to work. A COP of4 means that the heat pump generates four times what it needs tofunction. So the higher COP is, the more performant the heat pump is.A SPLIT HEAT-PUMP FOR IMPROVED PERFORMANCESIndoor hydraulic moduleOutdoor inverter unitCHARACTERISTICS• Patented, coaxial heat exchanger andClass A low consumption circulating pump• COP up to 4.5• Water curve control for 1 to 2 zone(s)management• Possible to manage 1 hydraulic zoneand 1 electric zone from the heat pump(option)• Easy to install: ergonomics of hydraulicmodule (fast access to all <strong>com</strong>ponents)• Complete programming functions includedSUPPLIESInverter outdoor unit:• Refrigerant circuit (R410A)• Scroll or Twin Rotary <strong>com</strong>pressor(depending on model)• Full Inverter controlIndoor module:• Coaxial immersed exchangerin buffer tank• Class A circulating pump• Water curve control (ambient sensoras option)• Outdoor sensor• Expansion vessel, pressure meter, etc.• Auxiliary electric back-up (optional)2


<strong>Technical</strong> characteristics and performancesUNITALFÉA ALFÉA ALFÉA ALFÉA ALFÉA ALFÉAEXTENSA 5 EXTENSA 6 EXTENSA 8 EXTENSA 10 EXTENSA 13 EXTENSA 16R410A R410A R410A R410A R410A R410AMAIN CHARACTERISTICSHeating capacity +7°C/+35°C – Floor Heating W 4 701 6 000 7 715 10 557 13 200 15 500Input power +7°C/+35°C – Floor Heating W 1 045 1 428 1 860 2 710 3 300 4 306COP +7°C/+35°C - Floor Heating 4.50 4.20 4.15 3.90 4.00 3.60Heating capacity -7°C/+35°C – Floor Heating W 4 712 5 030 6 551 8 310 10 300 12 152Input power -7°C/+35°C – Floor Heating W 1 747 1 887 2 730 3 410 3 960 4 865COP -7°C/+35°C - Floor Heating 2.70 2.67 2.40 2.44 2.60 2.50Heating capacity +7°C/+45°C – Low T°radiators W 4 275 5 680 7 231 8 105 10 300 13 034Input power +7°C/+45°C – Low T°radiators W 1 210 1 680 2 280 2 610 3 250 4 536COP +7°C/+45°C – Low T°radiators 3.53 3.38 3.17 3.11 3.17 2.87Heating capacity -7°C/+45°C – Low T°radiators W 4 103 4 770 6 396 8 065 9 250 10 780Input power -7°C/+45°C – Low T°radiators W 1 801 2 160 3 040 3 930 4 200 5 263COP -7°C/+45°C – Low T°radiator 2.28 2.21 2.10 2.05 2.20 2.05Additional electric backup in option*sound pressure level at 1 m from the appliance, 1.5 m from the ground, free field, directivity 2. - **sound pressure level at 5 m from the appliance, 1.5 m from the ground, free field, directivity 2.DimensionsWadjustable3 000 / 6 000adjustable3 000 / 6 000adjustable3 000 / 6 000adjustable3 000 / 6 000adjustable3 000 / 6 000adjustable3 000 / 6 000INDOOR HYDRAULIC MODULENoise level* dB(A) 39 39 39 39 39 39Sound pressure according to EN 12102 dB(A) 46 46 46 46 46 46Dimensions h x w x dmm800 x 450 x 800 x 450 x 800 x 450 x 800 x 450 x 800 x 450 x 800 x 450 x480480480480480480Net weight/filled weight kg 42 / 58 42 / 58 42 / 58 42 / 58 42 / 58 42 / 58HYDRAULIC CHARACTERISTICSBuffer tank capacity l 16 16 16 16 16 16Expansion vessel capacity l 8 8 8 8 8 8Heating system min./max. flow for 4°< T


Alféa ExtensaINSTALLATION SCHEMESA - Alféa Extensa:1 heating zoneOutdoor unit and ground supportRefrigerating connections645Hydraulic moduleBack up heaterRoom control unit3Outdoor sensorOR1 2B - Alféa Extensa: 2 heating zones + DHW productionOutdoor unit and ground supportRefrigerating connectionsHydraulic moduleBack up heater96478Circuit 25Room radio control unit2 zones kitDHW kit3Circuit 15Water tankOutdoor sensorOR61 2C - Alféa Extensa: Boiler 2 heating zones + DHW productionOutdoor unit and ground supportRefrigerating connectionsHydraulic moduleBoiler connection kitRoom radio control unit2 zones kitDHW kit91034978Circuit 2Circuit 155Water tankBoilerOROutdoor sensor6125


Alféa ExtensaPOWER CURVESPower curves - circulating pumpmbar1 mbar = 10 mmCE = 100Pambar1 mbar = 10 mmCE = 100Paext. inext. in600422460042245006 75006 7400400730063004200100242001002000,51 1,5 2 2,53m/h000,51 1,5 2 2,53m/hVariable pressureConstant pressureHeating and absorbed power curves6,00Floor heating7,00Floor heating5,00Low temperatures radiators6,00Low temperatures radiators4,00Heating power5,00Heating powerPower (kW)3,002,00Power (kW)4,003,002,001,00Absorbed power1,00Absorbed power0,00-20 -15 -10 -5 0 5 10 15 20 25 30Outside Temperature (°C)Power curves Alféa Extensa 50,00-20 -15 -10 -5 0 5 10 15 20 25 30Outside Temperature (°C)Power curves Alféa Extensa 69,008,00Floor heatingLow temperatures radiators12,0011,0010,00Floor heatingLow temperatures radiators7,006,00Heating power9,008,00Heating powerPower (kW)5,004,003,00Power (kW)7,006,005,004,002,003,001,00Absorbed power2,001,00Absorbed power0,00-20 -15 -10 -5 0 5 10 15 20 25 30Outside Temperature (°C)Power curves Alféa Extensa 80,00-20 -15 -10 -5 0 5 10 15 20 25 30Outside Temperature (°C)Power curves Alféa Extensa 1015,0014,0013,0012,00Floor heatingLow temperatures radiators17,0016,0015,0014,00Floor heatingLow temperatures radiatorsPower (kW)11,0010,009,008,007,006,005,004,00Heating powerPower (kW)13,0012,0011,0010,009,008,007,006,005,00Heating power3,004,002,00Absorbed power1,000,00-20 -15 -10 -5 0 5 10 15 20 25 30Outside Temperature (°C)Power curves Alféa Extensa 133,002,00Absorbed power1,000,00-20 -15 -10 -5 0 5 10 15 20 25 30Outside Temperature (°C)Power curves Alféa Extensa 166


Power curves - cooling mode6,007,00Floor cooling flow rating 18/245,00Fan coil unit flow rating 7/126,004,00Cooling power5,00Floor cooling flow rating 18/24Fan coil unit flow rating 7/12Cooling powerPower (kW)3,00Power (kW)4,003,002,002,001,00Absorbed power1,00Absorbed power0,001924293439440,00192429343944Outside Temperature (°C)Outside Temperature (°C)Alféa Extensa 5 Alféa Extensa 69,0014,008,00Floor heating flow rating 18/2412,00Floor cooling flow rating 18/24Fan coil unit flow rating 7/127,00Fan coil unit flow rating 7/1210,00Power (kW)6,005,004,00Cooling powerPower (kW)8,006,00Cooling power3,004,002,001,00Absorbed power2,00Absorbed power0,001924293439440,00192429343944Outside Temperature (°C)Outside Temperature (°C)Alféa Extensa 8 Alféa Extensa 1016,0018,0014,0016,00Power (kW)12,0010,008,006,00Floor cooling flow rating 18/24Fan coil unit flow rating 7/12Cooling powerPower (kW)14,0012,0010,008,006,00Floor cooling flow rating 18/24Fan coil unit flow rating 7/12Cooling power4,002,00Absorbed power4,002,00Absorbed power0,001924293439440,00192429343944Outside Temperature (°C)Outside Temperature (°C)Alféa Extensa 13 Alféa Extensa 167