12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Built-up <strong>Roofing</strong>INTEC/PERMAGLAS1. NUMBER OF REGIONAL SERVICE LOCATIONS: 62. LICENSED APPLICATOR AGREEMENT (yes/no): YES3. DISTRIBUTION METHOD (distributors and/or direct): DISTRIBUTORS4. PREFORMED ACCESSORIES AVAILABLE (yes/no): YES5. LIMITATIONS/RESTRICTIONS: SEE BUILT-UP ROOFING SYSTEMS MANUAL6. FOR SALES/TECHNICAL INFORMATION: 800/624–68327. FELTS DATA: TRADE NAME (applicable ASTM standard), COMBINATION BASE (D 4601, TYPE I)(metric [39 5/8-in. wide])ULTRA BASE (D 4601, TYPE I/II)TOUGH PLY IV (D 2178, TYPE IV)ULTRA PLY VI (D 2178, TYPE VI)ULTRA CAP (D 3909)PERMAVENT (D 4897, TYPE II)FLEX BASE 30 (D 4601, TYPE II)8. SPECIFICATION NUMBER M-B5UP- M-B4UP- ERA- ERA- G-4UP- G-B5TP- G-B4UP- M-4UP- ERA-N N 4UP-RI B5TP-RI RI RI N RI B4UP-N9. HOT AND/OR COLD APPLIED HOT HOT HOT HOT HOT HOT HOT HOT HOT10. DECK TYPENailable X X X XInsulated X X X X XNonnailable11. SLOPE REQUIREMENTS (range in inches) 1/4 – 3 1/4 – 3 1/4 – 3 1/4 – 3 1/4 – 3 1/4 – 3 1/4 – 3 1/4 – 3 1/4 – 3NUMBER OF PLIES12A. Total Plies 5 4 4 5 4 5 4 4 412B. Base Sheet 1 1 1 1 1 112C. Interply(ies) 3 2 4 4 4 4 3 3 312D. Cap Sheet 1 1 113. TYPES OF FELTGlass Fiber X X X X X X X X XOrganicAsbestosPolyesterOther14. INTERPLY ADHESIVEAsphalt X X X X X X X X XModifed AsphaltCoal TarElastomeric Adhesive15A. SURFACING - AGGREGATEGravel (lbs./ft 2 ) 4 4 4Slag (lbs./ft 2 ) 3 3 3Crushed Rock(lbs./ft 2 ) 4 4 415B. SURFACING - SMOOTHAsphaltCoal TarEmulsion/CutbackAluminum Coating X X XVinvl/Vinyl Coating15C. SURFACING - OTHERMineral GranulesCap Sheet X X XOther16. WEIGHT, INCLUDING PLIES (approx. lbs./ft 2 )Aggregate 6.0 6.0 6.0Smooth 2.0 2.0 2.0Cap Sheet 2.0 2.0 2.017. RESTRICTED REGIONS (refer to manufacturer's literature) NONE NONE NONE NONE NONE18. YEAR OF FIRST COMMERCIAL USE 1976 1976 1976 1976 1976 1976 1976 1976 197619. TEST RESULTS PER NBS BSS #55MD = MACHINE DIRECTIONXD = CROSS DIRECTIONA Tensile Strength (>200 lb/in @ 0 o F) -MD-XDB Thermal Expansion (not > 40x10 –6 / o F@0 o F to –30 o F) -MD-XDC Thermal Base Shock (not < 100 o F) -MD-XD20. SEE APPENDIX IF CHECKED66

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!