12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Metal Roof Panels1. COMPANY NAME FABRAL FABRAL2. PRODUCT NAME 2-1/2 SSR 1-1/2 SSR3. ARCHITECTURAL APPLICATIONS (yes/no) YES YESSTRUCTURAL APPLICATIONS (yes/no) YES YESPANEL CONFIGURATION4A. Panel Description STANDING SEAM ROOF PANEL STANDING SEAM4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHESGalvanized Steel (ga.) 18, 20, 22, 24, 26 / UNFINISHED, 24 / SUPRE ALURITEStainless Steel (ga.)S.P., KYNAR, VAP18, 20, 22, 24, 26 / MILLGalvalume (ga.)Aluminized Steel (ga.)18, 20, 22, 24, 26 / UNFINISHED,S.P., KYNAR, VAP0.032, 0.04, 0.05 / PLAIN WITH STUCCOEMBOSSING, SP, KYNAR, W/WO STUCCO EMB.Aluminum (ga.) 16Copper (ga.)Terne Metal (ga.)Zinc (ga.)4C. MAXIMUM LENGTH (lf.) 42 404D. PANEL WIDTHS (in.) 18 165. SYSTEMS REQUIREMENTSMinimum Slope (in. per ft.) 1/2:12 1:12Solid Decking (required, optional, or not used) OPTIONAL OPTIONALUnderlayment (type or NA)6. PANEL PROFILEVertical Leg X XTrapezoidalBattenOther (specify)7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;E = FIELD APPLIED; N = NONEE = FIELD APPLIED; N = NONEOverlappedCrimped (45 degrees)Roll Formed (180 degrees)Double Roll Formed (two 180 degrees)Roll and LockSnap-on Cap 2-1/2 / FSnap Together 1-1/2 / F8. FASTENING METHODThrough-Fastened, ExposedThrough-Fastened, ConcealedCLIP, CONCEALEDFixed ClipSlip Clip X XMoveable Clip (designed allowable movement, inches)9. SPECIALTY APPLICATIONSCurvedTaperedOther10. MANUFACTURER/PRODUCT DATAYear of First Commercial Use 1980 1987Number of Squares InstalledLicensed Applicator Agreement (yes/no) NO NOMethod of Distribution (distributors, direct)Number of Regional Service LocationsFor Sales Information, Contact: L. REESE L. REESEFor Technical Information, Contact: M. CROUCHER, JR. M. CROUCHER, JR.11. ASTM E331 WATER PENETRATION TEST RESULTS 5 GAL/HR PER SQ FT PRESSURE NO PENETRATION AT 25 PSF(results or none)DIFFERENTIAL 20 PSF 15 MINUTESWATER PENETRATION, NONE12, ASTM E 1646 WATER PENETRATION TEST RESULTS(results or none)13. ASTM E283 AIR INFILTRATION TEST RESULTS 0.0 CU FT/MIN PER SQ FT 0.09 @ 1.57 PSF(results or none)W/20 PSF PRESSURE14. ASTM E 1680 (AIR INFILTRATION TEST RESULTS(results or none)15. FM/UL WIND UPLIFT RATINGS FOR ANY SPECIMEN UL-90 UL-9016. SEE APPENDIX IF CHECKED X XNA=not applicable296

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!