12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Spray Polyurethane Foam-Based Systems; Protective Coatings -<strong>General</strong> Information1. COMPANY NAME QUANTUM QUANTUM QUANTUM QUANTUMCOATINGS, INC. COATINGS, INC. COATINGS, INC. COATINGS, INC.2. PRODUCT NAME FUTURA-THANE ELASTO-BOND FUTURA-FLEX ELASTO-BOND516 801 550 8203A. COATING DESCRIPTIONAcrylilcButylXHypalonNeopreneSiliconeXUrethane X XVinylModified AsphaltOther (type)3B. VAPOR RETARDER (yes, perm rating 1.0) YES YES YES NO3C. COLORS AVAILABLE GRAY BLACK, GRAY WHITE, DARK GRAY,OTHER COLORS LIGHT GRAY4. BASE COATING (Name of Product) SAME SAME ELASTO-BOND ELASTO-BOND801 (BASE) 820TOP COATING (Name of Product) SAME FUTURA-FLEX 550FUTURA-THANE 550 ELASTOBOND(TOP) OR SAME 8205. NUMBER OF COATING APPLICATIONS REQUIREDBase Coatings 1 – 2 1 – 3 1Top Coatings 1 1Granules Required (yes, no or optional) OPTIONAL NO NO OPTIONAL6. REQUIRED DRY FILM THICKNESS: (mils)Base Coating 30 – 40 20 – 35 10 – 12 1/2Tom Coating 10 – 15 10 – 12 1/27. FILM CURE TIMEBase Coating 6-12 HRS @ 75F 8-10 HRS @ 75F 3 – 4 HRS @ 75FTop Coating 6 – 8 HRS @ 75F 3 – 4 HRS @ 75F8. MINIMUM SLOPE REQUIRED (inches per foot) 1/8" 1/8" 1/8" 1/2"9. REQUIREMENTS FOR USE OVER:(X=direct application permitted) (P=primer required)(T=thermal barrier required)Concrete Decks X P X P X P X PPlywood Decks X P T X P T X P T X P TMetal Decks X P X P X P X PExisting Spudded Built-up <strong>Roofing</strong> X P X P X P X POther Coatings P P P P10. FLASHING MATERIAL (type or self-flashing) SELF SELF SELF SELF11. APPLICATION CONDITIONSRecommended Ambient Air Temperature Range (degrees F) 40 – 110 40 – 110 40 – 110 40 – 110Maximum Permitted Wind Velocity Without Screen (mph) 10 10 10 10Maximum Permitted Wind Velocity With Wind Screen (mph) 15 15 15 1512. APPLICATION EQUIPMENT REQUIREMENTSSingle-Component Airless Spray X X X XMulti-Component Airless Spray XOther (roller, brush, etc.) ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH ROLLER, BRUSH13. RESTRICTED REGIONS (yes/none) NONE NONE NONE NONE14. RESTRICTED BUILDING USES (yes/none) YES NO YES YES15. RECOMMENDED RECOATING SCHEDULE (years or none) 5 – 10 5 – 10 5 – 10 5 – 1016. PHYSICAL PROPERTIES OF THE COATINGTensile Strength Per ASTM D 412 or Other (psi) 500±100 375±25 2700±50 450-550Elongation Per ASTM D 412 or Other (%) 200±30 180±25 275±25 140±10Impact Resistance Per ASTM D 2794 or Other (inch lbs)Accelerated Weathering Per ASTM D 882 or Other (color change) NO CHANGE NO CHANGE NO CHANGE NO CHANGEHeat Aging Per ASTM D 573 or Other (%) NO CHANGE NO CHANGE NO CHANGE NO CHANGEWater Absorption Per ASMT D 570 or Other (%) 1 MAX 0.5 1.5 0.5±0.117. UL 790 FLAMMABILITY CLASS A RATING IN ANY SYSTEM (yes/no) YES YES YES YES18. FOAM INSULATION REQUIREMENTSMinimum Thickness (inches) 1 – 1 1/2 1 – 1 1/2 1 – 1 1/2 1 – 1 1/2Nominal Density Per ASTM D 1622 or Other (lbs/ft 3 ) 2.5 – 3 2.5 – 3 2.5 – 3 2.5 – 3Compressive Strength Per ASTM D 1621 or Other (psi) 40 MIN. 40 MIN. 40 MIN. 40 MIN.Closed Cell Content Per ASTM D 2856 or Other (%) 90 MIN. 90 MIN. 90 MIN. 90 MIN.19. FOAM AVAILABLE FROM MANUFACTURER (yes/no) NO NO NO NO20. YEAR OF FIRST COMMERCIAL USE 1988 1980 1979 198721. NUMBER OF SQUARES INSTALLED (100 ft 2 ) 600,000+ 1 MILLION+ 5 MILLION+ 1.2 MILLION+22. MANUFACTURER-QUALIFIED APPLICATOR REQUIRED (yes/no) YES YES YES YES23. METHODS OF DISTRIBUTION (distributors and/or direct) DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT DISTRS, DIRECT24. NUMBER OF REGIONAL SERVICE LOCATIONS 5 5 5 525. FOR SALES INFORMATION, CONTACT: B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE314/521–4100 314/521–4100 314/521–4100 314/521–4100FOR TECHNICAL INFORMATION, CONTACT: B. SCHENKE B. SCHENKE B. SCHENKE B. SCHENKE26. SEE APPENDIX IF CHECKEDNA=not applicable314/521–4100 314/521–4100 314/521–4100 314/521–4100271

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!