12.07.2015 Views

Teleservice - Lösungen in „SIMATIC"

Teleservice - Lösungen in „SIMATIC"

Teleservice - Lösungen in „SIMATIC"

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Automation and DrivesAutomation and DrivesGG-Kennungoder ProduktnameTeleServiceSolutions <strong>in</strong>“SIMATIC”


Automation and DrivesOverview„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9TeleService (TS)Comprised of coord<strong>in</strong>ated components:• TS adapter• TS software• Function blocks (FBs) forremote ma<strong>in</strong>tenance, remote coupl<strong>in</strong>g, alarmvia SMS, e-mail or faxGliederungspunkt 10TeleServiceA&D AS, 07/2003, Chart 2© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesYour benefits„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Benefits:SIMATIC TeleService offers a low-cost and<strong>in</strong>tuitive solution for remote ma<strong>in</strong>tenance andremote coupl<strong>in</strong>gspecially adapted to your <strong>in</strong>dustrialautomation application.Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Gliederungspunkt 10TeleServiceA&D AS, 07/2003, Chart 3© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesWhy remote ma<strong>in</strong>tenance?„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4TeleService drastically reduces service callsService calls asa percentage120SIMATIC remote ma<strong>in</strong>tenancereduces on-site service calls by upto 60%System ConfigurationGliederungspunkt 5Remote Gliederungspunkt Ma<strong>in</strong>tenance 610080100 %Remote Gliederungspunkt Coupl<strong>in</strong>g 7Messag<strong>in</strong>g Gliederungspunkt 8ParameterizationGliederungspunkt 9Gliederungspunkt 106040200TeleService40 %-60 %-50 %20 %10 %-50 %Without <strong>Teleservice</strong> Control l<strong>in</strong>k With video transmission With additional sensorsA&D AS, 07/2003, Chart 4© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesCosts„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Gliederungspunkt 10Remote ma<strong>in</strong>tenance and remoteprogramm<strong>in</strong>g with S7 TeleService• Costs per system are fixed• Industry modem(start<strong>in</strong>g atapprox. € 200)• TS adapter V5.2 (approx. € 380)6ES7 972-0CA34-0XA0• “TeleService” option package V5.2 (approx. € 500)6ES7 842-0CC03-0YE0TeleServiceA&D AS, 07/2003, Chart 5© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesCosts„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Remote ma<strong>in</strong>tenance and remoteprogramm<strong>in</strong>g with S7 TeleService• No travel expenses for service calls• Variable telephone costs• Either direct call<strong>in</strong>g by service eng<strong>in</strong>eer or• Callback from the systemGliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Gliederungspunkt 10TeleServiceA&D AS, 07/2003, Chart 6© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesSystem configuration„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2ServicePLCOPPLCBenefitsGliederungspunkt 3Telephone networkTeleService CostsGliederungspunkt 4TS adapterGliederungspunktSystem Configuration5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Gliederungspunkt 10Functions:• Remote ma<strong>in</strong>tenance• Remote coupl<strong>in</strong>g – automation system (AS) to PC• Remote coupl<strong>in</strong>g – AS to AS• Direct SMS messag<strong>in</strong>g via TS adapterMPITeleServiceA&D AS, 07/2003, Chart 7© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesRemote ma<strong>in</strong>tenance with S7 TeleService„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9“Extension of the MPI <strong>in</strong>terface via thetelephone network”• Access to remote CPUs us<strong>in</strong>g STEP 7, ProTooland all programm<strong>in</strong>g tools (e.g. S7-SCL)• No PG/PC required on the system side• System only requires a modem and aTS adapter• Service requires a modem and the TS softwareGliederungspunkt 10TeleServiceA&D AS, 07/2003, Chart 8© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesRemote ma<strong>in</strong>tenance with S7 TeleService„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Gliederungspunkt 10Uses commonly available modems• Analog• Digital• Mobile radio networksAll users can be reached, same as via MPI• CPUs (S7, C7 or M7)• Operator panelsTeleServiceA&D AS, 07/2003, Chart 9© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesRemote ma<strong>in</strong>tenance configuration„SIMATICTeleService“Gliederungspunkt 1PC/PCOverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4S7-400TS adapterTelephone l<strong>in</strong>eModemSystem ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Gliederungspunkt 10S7-300ModemAccess via TS adapter possible without on-sitePG, direct connection to:• PROFIBUS• MPITeleServiceA&D AS, 07/2003, Chart 10© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesRemote ma<strong>in</strong>tenance configuration„SIMATICTeleService“Gliederungspunkt 1PC/PCOverviewGliederungspunkt 2BenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4S7-400Telephone l<strong>in</strong>eModemSystem ConfigurationGliederungspunkt 5S7-300Gliederungspunkt Remote Ma<strong>in</strong>tenance 6S7-300Remote Gliederungspunkt Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Gliederungspunkt 10Rout<strong>in</strong>g functionality reta<strong>in</strong>ed for PG functions,also provid<strong>in</strong>g access beyond networkboundaries!TeleServiceA&D AS, 07/2003, Chart 11© Siemens AG 2003 - Subject to change without prior notice


Remote coupl<strong>in</strong>g configuration –AS to PG/PCAutomation and Drives„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2Automation system (AS)S7-300/S7-400, C7PG/PCBenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4User programRemote connectionUser programSystem ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6FB 46 “PG_DIAL”PRODAVEGliederungspunkt Remote Coupl<strong>in</strong>g7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9MPI network TS adapter Modem Telephone ModemnetworkGliederungspunkt 10TeleServiceA&D AS, 07/2003, Chart 12© Siemens AG 2003 - Subject to change without prior notice


Remote coupl<strong>in</strong>g configuration –AS to ASAutomation and Drives„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2Localautomation system (AS)S7-300/S7-400, C7Local CPURemoteautomation system (AS)S7-300/S7-400, C7Remote CPUBenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4User programRemote connectionUser programSystem ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6FB 47 “AS_DIAL”Gliederungspunkt Remote Coupl<strong>in</strong>g7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9Local MPVPDnetworkLocalTS adapterLocalmodemTelephonenetworkRemotemodemRemoteTS adapterRemote MPVPDnetworkGliederungspunkt 10TeleServiceA&D AS, 07/2003, Chart 13© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesDirect messag<strong>in</strong>g via SMS, e-mail or fax„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2Automation system (AS)S7-300/S7-400, C7FaxBenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6User programFB 48 “SMS_SEND”E-mailGliederungspunkt Remote Coupl<strong>in</strong>g 7MobileGliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization 9MPI networkTS adapterRadio modemTelephone radio networkandnetwork providerGliederungspunkt 10TeleServiceA&D AS, 07/2003, Chart 14© Siemens AG 2003 - Subject to change without prior notice


Automation and DrivesAdapter parameterization„SIMATICTeleService“Gliederungspunkt 1OverviewGliederungspunkt 2Remote ma<strong>in</strong>tenance and remoteprogramm<strong>in</strong>g with S7 TeleServiceBenefitsGliederungspunkt 3TeleService CostsGliederungspunkt 4System ConfigurationGliederungspunkt 5Gliederungspunkt Remote Ma<strong>in</strong>tenance 6Gliederungspunkt Remote Coupl<strong>in</strong>g 7Gliederungspunkt Messag<strong>in</strong>g 8Gliederungspunkt Parameterization9Gliederungspunkt 10• Password-protected access andcallback function• Remote parameterization viamodem• Users can modify only their owndata• Adm<strong>in</strong>istrator can modify all data• Direct operation permittedComplete re-parameterizationTeleServiceA&D AS, 07/2003, Chart 15© Siemens AG 2003 - Subject to change without prior notice

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!