12.07.2015 Views

FC HBA Driver for Mac OS X Release Notes - QLogic

FC HBA Driver for Mac OS X Release Notes - QLogic

FC HBA Driver for Mac OS X Release Notes - QLogic

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3. Bug FixesThe following bug fixes have been made to the <strong>FC</strong> <strong>HBA</strong> <strong>Driver</strong> <strong>for</strong> <strong>Mac</strong> <strong>OS</strong> X between versions 2.00.02 and2.00.03. See revision.notes <strong>for</strong> details.● Changed the call to TaskWithOptions such that minimum memory allocation size is PAGE_SIZE.● Used firmware calculated residual length <strong>for</strong> 4Gb <strong>HBA</strong>.[ER56525/ER51903]● Restricted Port Login retries.● Fixed all DEBUG message compile time errors.● Fixed panic in IOCTL path by increasing timeout value.[ER56525/ER51903]● Returned data in MBytes instead of Bytes <strong>for</strong> getting Statistics.● Modified License file time span to include 2007.● Corrected endianess issue while interrogating MS status.● Honored 4Gb <strong>HBA</strong> NVRAM settings <strong>for</strong> LIP reset, full login LIP, and corrected "LIP Followed by Login"mailbox command issuance.● Corrected endianess comparisons during 4Gb <strong>HBA</strong> NVRAM configuration.● Fixed problem so the driver doesn't wait <strong>for</strong> loop transition to complete if loop is dead.● Added patch <strong>for</strong> "<strong>HBA</strong> registers not being mapped to IO or Memory space.● Fixed STOP FIRMWARE issue by adding I<strong>OS</strong>CSIPCI interrupt enable statement.● Fixed Register Mailbox Test issue.● Fixed SendRLS by using get_link_status instead of MS IOCB.● Corrected issue where driver improperly issued SNS commands in N2N topologies.● Honored 'skip process-login' option during fabric-login IOCB.● Resynchronized with latest released 4Gb <strong>HBA</strong> firmware: 4.00.26.● Corrected large-buffer transfer issues during loopback test.● Per<strong>for</strong>med implicit LOGO during fabric logout request.4. Known IssuesNone5. HistoryFor a complete history, see the revision notes provided in the software package.6. Additional In<strong>for</strong>mationNone7. Firmware (Embedded in <strong>Driver</strong>)This section provides release details <strong>for</strong> the firmware embedded in the driver.7.1 2Gb <strong>HBA</strong>sThe following table shows the changes and bug fixes made to the ISP23xx Risc firmware between versions3.03.18 and 3.03.19.ChangesChangeDescriptionFrom 3.03.18 to 3.03.19[ER43794] Firmware initiated login to Fabric Name Server is now retried if there is a timeout.[ER44240]ISP2322 only. Modify auto speed negotiation to inter-operate with certain switches.<strong>FC</strong> <strong>HBA</strong> <strong>Driver</strong> <strong>for</strong> <strong>Mac</strong> <strong>OS</strong> X <strong>Release</strong> <strong>Notes</strong> 2 of 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!