<strong>Katherm</strong> Ultra 6000 <strong>GK</strong> 1.54 1.46Ready-to-install underfloor convector mit heaters 2-Stufen • Fan-assisted Drehstrommotor convection 400 VInstallation <strong>Electrical</strong> und Montage wiring1. Correct and proper useKampmann fan-assisted floor duct heaters have beenmanufactured in accordance with state of the art engineeringand recognised safety directives. However incorrect installationand commissioning of the units together with improper use ofthe units can cause fatal injury, damage to the unit heaters ordamage to other units or systems.Kampmann fan-assisted floor duct heaters should only be usedto provide supplementary heating, to screen off cold air ingressand warm areas up rapidly. The units should not be used for anypurpose other than the one described above. Correct andproper use is also understood as meaning the implementationof the installation instructions given in this manual.The installation of these units requires technical expertise in thefields of heating, cooling and ventilation, and preferably atechnical qualification in one of the aforementioned fields.Damage resulting from improper installation is the soleresponsibility of the user.CablingRoom thermostatwith integral fanspeed controllertype 146924Mains230 V/50 HzMains230 V/50 HzMains230 V/50 Hz3 x 1,5 3 x 1,5 3 x 1,56 x 1,5(5 x 1,5)*Roomthermostattype 146927Fan speedcontrollertype 1469264 x 1,5(3 x 1,5)*6 x 1,5(5 x 1,5)*Clockthermostattype 146910Fan speedcontrollertype 1469264 x 1,5(3 x 1,5)*6 x 1,5(5 x 1,5)*2. Important safety informationThese units should be wired and serviced by qualifiedelectrical technicians in accordance with VDE or ENstandards and recognised electrical guidelines.Non-observance of these directives and of the detailedinstructions provided in the installation manual may causemalfunction of the unit, resulting in damage to the unit itselfand possible fatal injury. Incorrect wiring may also result in fatalinjury!All parts of the system should be disconnected from the mainsprior to electrical wiring and service work being carried out.6 x 1,5(5 x 1,5)*6 x 1,5(5 x 1,5)*to further fan-assistedfloor duct heatersThe no. of wires and their crosssection(i.e. 6 x 1.5) is indicated foreach control unit.The number in brackets should beused in the absence of athermoelectric actuator i.e. ifthermostatic valve type 146907 isused.Switch-junction boxes should be usedwhen fitting thermostats and speedcontrollers.3. <strong>Electrical</strong> wiring• Cut the plastic packaging from the fan end of the unit.• Fold it back but do not cut it off.• Remove the fan cover and filter.• Remove the cover for the speed controller terminal strip andconnect the wires as shown on the wiring diagram on thereverse.• Apply power and check that the unit is operating correctly.• If the unit is operating correctly, switch power off, replaceterminal strip cover, fan cover and filter.• Re-apply power. The unit is now operational.Maximum no. of floor duct heaters per speed controller<strong>Katherm</strong><strong>Katherm</strong> <strong>GK</strong>lengths up to NP 5000 mmRaised capacity with 1 fan,lengths up to NP 5000 mmSuper capacitywith 1 fan, max. length NP 3250 mmSuper capacitywith 2 fans, length more than 3250 mmmax. no. which can be connected1010105Fan-assisted floor duct heaterExample:Raised capacity floor duct heater with lineargrille11Linear grille (roll-up type)2Fan cover with filter3Speed controller4Terminal strip coverSpeed controller5Air flow guide wall6Radial fan7Frame to match grille 78Base plate with fan9Sendzimir galvanised,graphite-grey floor ductblSteel bracketsbnHigh output convectorboScreed anchorsbpMounting bracketsbq<strong>Electrical</strong> connection/opening for cable23456 89bqbnblbobpI 110/02/03/0.5 GBSYSTEMS FOR HEATING · COOLING · VENTILATING


1.54 1.46 <strong>Katherm</strong> <strong>GK</strong>Ready-to-install underfloor convector heaters • Fan-assisted convection<strong>Wiring</strong> diagramsFloor duct heaters with 1 fanRoom thermostatwith speed controllertype 146924Room thermostatwith speedcontrollertype 146927Speed controllertype 146926Clockthermostattype 146910Speed controllertype 146926FanJunction boxFanJunction boxSpeed controllerThermoelectricactuatortype 146905Speed controllerThermoelectricactuatortype 146905Floor duct heaterFloor duct heaterSuper capacity floor duct heaters with two fans (longer than NP 3250mm)FanFanJunction boxSpeed controllerThermoelectricactuatortype 146905Speed controllerAll super capacity floor duct heaters longer than NP 3250mm are fitted with two fans.The fans are factory-wired to each other in the floor duct heater.2SYSTEMS FOR HEATING · COOLING · VENTILATIN<strong>GK</strong>AMPMANN GMBH · 49794 Lingen · GermanyFriedrich-Ebert-Strasse · Postfach 6044Tel. +49 (0) 5 91-7108-0 · Fax +49 (0) 5 91-7108-300info@kampmann.de · www.kampmann.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!