Reference<br />
air tstrmg<br />
Zircoma<br />
substrate<br />
Protection tUbe Platmum electrode<br />
3. Protection tube (nght) of stainless steel<br />
IS aimed at Improving probe's ability to withstand<br />
extreme furnace conditions<br />
greatly Improve the service life of the<br />
high-temperature O 2 probes appeared to be<br />
m the superheater area of the bOiler convection<br />
pass Rather than bemg exposed to<br />
harsh envIronmental conditions In the<br />
open area of the furnace the probes would<br />
have maxImum protection wlthm the secondary<br />
pendant tubes (Fig 2).<br />
Consequently, four 02 probes were<br />
Installed m the secondary superlleaJer secbon<br />
of the fumace-iWo m each SIdewall.<br />
A potential nsk m putting them there was<br />
they would be close to the sootblowers.<br />
After the probes were m servICe., the sootblower<br />
nearest each probe was opernted. It<br />
was found that sootblower operatIon<br />
would not damage the probes The O2 system<br />
could now be momtored to evaluate<br />
the performance and longevity of the<br />
probes.<br />
The bottom line. Imtlal tnals on Unn<br />
7's hIgh-temperature 02 system show that<br />
the probes have good potential for apphca-<br />
HI-TEMP CARBON<br />
AND OXYGEN SENSORS,<br />
ELECTRONICS<br />
AND ACCESSORIES.<br />
tJon to utility bOIlers The knowledge<br />
gamed from these tnals was put to good<br />
advantage when a hIgh-temperature 02<br />
system for Unit 8 was mstalled. mcludmg<br />
four probes m the pendant reheat area of<br />
the convection pass. After continuous<br />
operation for over a year, none of Unlt 8's<br />
probes have faded.<br />
Results to date have shown differences<br />
of O 2 measurement taken at the economizer<br />
of 0 4% to 2.5% when compared to the<br />
hIgh-temperature probe readmgs Probe<br />
performance has been so successful that<br />
the economIzer O2 system Will be phased<br />
out at Nipsco Also, operator confidence 10<br />
02 measurement of flue gas has been<br />
restored Tom Elliott<br />