ECO-06 MAZUT SONIC FLOW METERS<br />
The audit team learned through intervIews with station personnel that one area whIch has<br />
hampered the stations progress m energy Improvements IS the mabilIty to accurately measure the<br />
decrease m fuel consumption due to any changes in operation or equipment motivated by<br />
efficiency improvement ThIS is because the eXIsting fuel flow mstruments in place at the statIon<br />
are maccurate or don't work. If only modest gams m effiCIency could be realIzed due to the<br />
mcentIve proVIded by the abIlIty to more accurately evaluate such Improvements, such flow<br />
momtonng equipment could pay for Itself m a very short penod.<br />
Lme sizes and design informatIOn were obtained for speCIfying somc flow meters for two supply<br />
and two return mazut lines serving the boilers.<br />
ECO-07 ON-LINE NATURAL GAS CALORIMETER<br />
The most important concern and pnonty at Burshtyn was the urgent need for analytical<br />
instruments for momtonng fuel qUalIty (coal, mazut, gas). The data mdIcates that the plants are<br />
paying large sums of money for fuel energy content (heatmg value) whIch they do not receIve.<br />
Instruments for measuring the fuel heat value m Kcal/Kg and other parameters would prOVIde<br />
the documentation necessary for making claIms agaInst suppliers.<br />
They urgently need an on-Ime gas calorimeter to verify the heat content supplIed by Gasprom.<br />
Their laboratory calorimeter is not commercial (certified), the tests are not contmuous so they<br />
cannot make a claim for credIts. We were given test results for monthly averages for 1994, as<br />
well as gas consumption. The plant claims losses of about 1.905 X 10 10 Kcal (7.559 X 10 10<br />
BTU's) which results in $159,000 loss per year. Although thIS loss of expenSIve gas fuel<br />
heatmg value has nothmg dIrectly to do WIth "combustIOn" efficiency, this IS also a pnority m<br />
reducing the large sums of hard currency they must pay for fuel gas.<br />
ECO-08 COAL FLOW METER<br />
The audIt team learned through mterviews WIth plant personnel that one area WhICh has<br />
hampered the plant progress in energy improvements IS the mabilIty to accurately measure the<br />
decrease In fuel consumption due to any changes m operatIOn or eqUIpment motivated by<br />
efficiency Improvements. This is because the plant does not have instruments to measure the<br />
fuel flow for eIther mazut and coal to each boiler. Natural gas flow meters already exist per<br />
each bOIler and work well. If only modest gaIns m effiCIency could be realized due to the<br />
mcenhve prOVIded by the abIlIty to more accurately evaluate such Improvements, such flow<br />
momtonng eqUIpment could pay to Itself m a short period of hme. Instruments to measure raw<br />
coal consumption to 200 MW Umt #4 on belt conveyors, located between raw coal bunkers and<br />
mills (coal feeder) are recommended.<br />
For detailed calculations see Appendix A-I.<br />