However, there are no records kept In the register books of the exhausts Into the<br />

atmosphere, nor IS kept the register for the exhausts measurements (the forms of the<br />

registers were recommended due to "Instructions for organizing control of the exhausts at<br />

a HPP" - RD 34 02.306-88) Enerac-2000 was not used by the laboratory of the HPP<br />

dunng 1996 due to the resource of the oxygen analyzer to be over<br />

On March 18, 1997, the laboratory of the State Committee for the Natural Resources and<br />

Environment, p20 - function together with the laboratory of the HPP performed parallel<br />

taking samples from the operated bOiler systems The laboratory of the State Committee<br />

used the natIonal production Instrument - "Inspector - 1 - Express-Method", the Laboratory<br />

of the HPP used "Enerac-2000<br />

The companson of the results shows discrepancy between the values concerning the<br />

exhausts For example, when the steam bOilers BKZ-160-FB on No 1 are being operated,<br />

the analytical control Instrument registers absence of CO In the fuel gas exhausts (Enerac­<br />

2000), the express-method "Inspector" determines their presence on the level of 62 5<br />

mg/m, that IS within the process requirements and corresponds to the approved maximum<br />

admitted exhausts levels<br />

AnalysIs for the Boiler BKZ-160-100FB at No 3 was not performed by the laboratory of the<br />

State Natural Protection Committee due to the mismatching the sample-taking holes<br />

In the exhausts of the water heating bOiler KVGM-1 00 at No 1, measurements with both<br />

the Instruments show presence of CO, the values determined by the laboratory of the State<br />

Committee IS higher In thiS case too than those determined by the HPP<br />

The values for the nitrogen oXide exhausts are practically the same, except for the<br />

exhausts from BKZ-160-1 OOFB at No 1, the reading from Enerac-2000 IS 102 5 mg/m 3 , the<br />

reading from "Inspector" IS 150 mg/m 3 The results of the checking measurements are<br />

attached<br />

As the method of "Inspector 1" IS a test-method, It IS suggested to carry out two parallel<br />

measurements by Enerac-2000 and uSing the Instruments "TESTO-33" from the laboratory<br />

of DONORGRES The results shall be In wntten form submitted to the inspection<br />

Concerning formation and arrangement of the wastes, there has been found as follows<br />

According to the data from the HPP, the territory IS made up of three areas with the total<br />

area of 26 88 hectares<br />

1 - 23 18 he - the Industnal area<br />

2 - 3 09 he - the ash-dumping area<br />

3 - 0 6 he - an area In the collective orchards zone<br />

In the limits on arrangement of the wastes Issued by the State Committee for the Natural<br />