Off-Module Panel ConnectorConnections24" maximum.Off-module fin wallmust always be the sameheight, or shorter than thespine wall.Fin wall can be no morethan 24" shorter than thespine wall. If there is morethan a 24" difference, anadditional horizontal barmust be added to the spinewall at the same height asthe fin wall. A stacking horizontalframe kit must beused.Spine wall skins mustbe segmented with a seammatching the height of theshorter fin wall. This allowsaccess to the top bracketand the spine wall horizontalbar.When stacking on thefin panel, the spine wallskins must be segmentedwith a seam matching theheight of the fin base panel.When stacking wallstart junctions in an offmoduleapplication, the offmodulepanel connectorconnects to the base wallstart junction.Two off-module panelscan be connected back toback at the same location..When connecting twooff-module fins at differentheights oneither side of the spinepanel, an additional horizontalbar must be orderedand installed at the sameheight of the shorter finpanel.4"3"An off-module fin wallcannot connect flush to theend of a panel in the spinewall. The closest connectionpoint will leave a 3" tail onthe spine including the endof run trim.An off-module fin wallcannot attach at a junctionin the spine wall. There is a2" area of dead space oneither side of the junctionrendering a total of 4" deadspace.An off-module fin wallcannot be installed over awindow that is located at thetop of a spine panel..Wiring & CablingWiring and cablingcomponents cannot berouted internally from aspine wall to an off-modulefin wall without cutting openingsin the spine wall skin.Tip: It is recommended thatyou route wiring and cablingthrough the spine wall.Internode power componentsshould be used tobring power from the spinewall to the workstation..Surface MaterialsOff-module bracket• Black paintTip: Bracket is hidden whenproperly installed.Off-module installationrequires field modificationof the light seal on the topskin. Surface covering is noteffected..Application TopicsStability <strong>Guide</strong>linesfor Application RulescPage 47Stacking junctionscan be used with any heightbase junction.Bins, shelves, andworksurfaces cannot beattached off-module..Panels<strong>Answer</strong> <strong>Solutions</strong> <strong>Specification</strong> <strong>Guide</strong> 27

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!