12.07.2015 Views

LCP Metaphyseal Plate for distal medial tibia ... - Osteosyntese

LCP Metaphyseal Plate for distal medial tibia ... - Osteosyntese

LCP Metaphyseal Plate for distal medial tibia ... - Osteosyntese

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong><strong>tibia</strong>. Anatomically precontouredmetaphyseal plate.


<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong><strong>tibia</strong>. Anatomically precontouredmetaphyseal plate.IndicationsThe <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong><strong>tibia</strong> is a preshaped plate that allows optimaltreatment of juxta-articular fractures ofthe <strong>distal</strong> <strong>tibia</strong> extending into the shaft area.This plate takes the following characteristicsof the <strong>distal</strong> <strong>tibia</strong> into account:– Thin, soft tissue coverage– Complex anatomic shape of the boneFeatures and benefitsAnatomically precontoured plateThe anatomical shape of the plate isespecially designed to fit the complexshape of the <strong>distal</strong> part of the bone.A twist of the plate optimizes the fit onthe <strong>tibia</strong>.<strong>LCP</strong> combination holesThe <strong>LCP</strong> combination hole allows aninternal fixation using standard screws,angle-stable locking head screws, ora combination of both. This takes intoaccount the most diverse intraoperativerequirements.Thinned plate profileThe <strong>distal</strong> part of the plate is tapered topreserve the thin soft tissue envelope ofthe <strong>distal</strong> <strong>tibia</strong>.Optimal <strong>distal</strong> application of thelocking head screwsThe specific orientation of the four <strong>distal</strong>screws allows optimal fixation in theepiphyseal area without penetrating thearticulation.2 Synthes <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>


Features and benefitsIncreased hole density providesimproved anchorageIn the <strong>distal</strong> part of the plate a tight networkof 3.5 <strong>LCP</strong> combination holes allowsinserting the screws closer to each other.Guiding blocksThe guiding block allows an easy andcorrect insertion of the drill sleeves in the<strong>distal</strong> area of the plate. The guiding blockcan be removed or placed back onto theplate even with drill sleeves in place. Ifdesired, standard screws can be insertedbe<strong>for</strong>e placing the guiding block.Additional design features– Bullet nose tip <strong>for</strong> easier application ofa minimally invasive surgical technique.– The K-wire hole in the bullet nose can beused conveniently <strong>for</strong> temporary fixation.– The longer hole in the shaft area of theplate facilitates fine tuning of the reductionin the longitudinal axis.– Improved vascularisation of the bonedue to plate undercuts that reduce theplate-to-bone contact.3


<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong><strong>tibia</strong>. Anatomically precontouredmetaphyseal plate.Surgical stepsImplant preparation1. Place the guiding block onto the plate.Thread the <strong>LCP</strong> Drill Sleeve (323.027)through the guiding block into the plate.If desired, the guiding block can thenbe removed.2. Precise contouring of the plate is un necessary.Take the screw direction intoconsideration when plate bending isrequired.3. Use the Guide Sleeve <strong>for</strong> Kirschner Wires(324.081) and insert the Kirschner wiresto determine the direction of the screws orsimply to temporarily fix the plate to thebone.For temporary fixation, a Kirschner wirecan also be placed through the hole in thebullet nose.4 Synthes <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>


<strong>Plate</strong> fixation1. Use the <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong><strong>medial</strong> <strong>tibia</strong> according to the <strong>LCP</strong> Principles;see <strong>LCP</strong> Application notes (036.000.465).2. For improved anchorage in the bone,the direction of the threaded screw holes inthe <strong>distal</strong> part of the plate has been optimized.To insure correct insertion andlocking of the locking head screws in this<strong>distal</strong> part of the plate, use the appropriateguiding block and <strong>LCP</strong> drill sleeves. Forthe <strong>distal</strong> part of the plate, use 3.5 mm lockinghead screws, 3.5 mm cortex screws, 4.0mm cancellous bone screws, or a com binationof all three.3. For the shaft of the plate, use 5.0 mmlocking head screws, 4.5 mm cortex screwsor a combination of both.5


<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong><strong>tibia</strong>. Anatomically precontouredmetaphyseal plate.<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, rightSt. Steel Titanium Designation Length224.768 424.768 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+4 holes 123 mm224.769 424.769 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+5 holes 141 mm224.770 424.770 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+6 holes 159 mm224.771 424.771 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+7 holes 177 mm224.772 424.772 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+8 holes 195 mm224.773 424.773 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+9 holes 213 mm224.774 424.774 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+10 holes 231 mm224.776 424.776 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+12 holes 267 mm224.778 424.778 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+14 holes 303 mm224.780 424.780 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+16 holes 339 mm224.782 424.782 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+18 holes 375 mm224.784 424.784 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 4+20 holes 411 mmGuiding Block <strong>for</strong> <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right312.936<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, leftSt. Steel Titanium Designation Length224.808 424.808 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+4 holes 123 mm224.809 424.809 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+5 holes 141 mm224.810 424.810 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+6 holes 159 mm224.811 424.811 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+7 holes 177 mm224.812 424.812 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+8 holes 195 mm224.813 424.813 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+9 holes 213 mm224.814 424.814 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+10 holes 231 mm224.816 424.816 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+12 holes 267 mm224.818 424.818 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+14 holes 303 mm224.820 424.820 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+16 holes 339 mm224.822 424.822 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+18 holes 375 mm224.824 424.824 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 4+20 holes 411 mmGuiding Block <strong>for</strong> <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left312.9376 Synthes <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>


<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> SetItem no.Designation171.250 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> Set with contents, stainless steel171.255 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> Set with contents, titanium671.205 SYNCASE <strong>for</strong> <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> Set, consisting of:671.206 Case <strong>for</strong> <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> <strong>Plate</strong>s671.207 Lid to SYNCASE <strong>for</strong> <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>Implants contained in the <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> Set 171.250Stainless steel Designation Units224.768 – 224.784 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 1 each224.808 – 224.824 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 1 eachImplants contained in the <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> Set 171.255Titanium Designation Units424.768 – 424.784 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 1 each424.808 – 424.824 <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 1 eachInstruments contained in the <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong> SetItem no. Designation Units312.936 Guiding Block <strong>for</strong> <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, right 1312.937 Guiding Block <strong>for</strong> <strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong> <strong>tibia</strong>, left 17


<strong>LCP</strong> <strong>Metaphyseal</strong> <strong>Plate</strong> <strong>for</strong> <strong>distal</strong> <strong>medial</strong><strong>tibia</strong>. Anatomically precontouredmetaphyseal plate.Ö036.000.835öAAMäPresented by: 0123036.000.835 SE_009041 AA © Stratec Medical 2005 Printed in Switzerland LAG Subject to modifications.