<strong>Quick</strong> <strong>Selection</strong> <strong>Guide</strong><strong>Edition</strong> <strong>2011</strong>DC-DC Converters


DC-DC ConvertersAVP-SeriesPCB MountingAVP/J AVP/Jsp AVP.../Ksp AVP.../K• Isolated• Single, dual, bipolar and tripleoutput• CE marked• Burst transients according toEN 61000-4-4max. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)Input Voltage Ranges (VDC)Operating Temperature in °C36AVP-3Ksp103.5x46x353+5, ±12/+5, ±159-40/15-36/32-74/66-154-40 up to +8541AVP-2D/K90.5x65.5x3525, 12/5, 159-40/15-36/32-74/66-154-40 up to +8542AVPJ90.5x65.5x2515/12/15/24/309-40/15-36/32-74/43-101/66-154-40 up to +8551AVP-2B/K90.5x65.5x352±12/±159-40/15-36/32-74/66-154-40 up to +85• Surge according to EN 61000-4-5• Conducted immunity according toEN 61000-4-6• Electrostatic discharge accordingto EN 61000-4-2• Conducted RFI:– Input filtering according toEN 55022• According to Railway StandardEN 50155 and EN 50121-3-2max. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)Input Voltage Ranges (VDC)Operating Temperature in °C47AVP-2D/Ksp103.5x46x3525, 12/5, 159-40/15-36/32-74/66-154-40 up to +8551AVP-2B/Ksp103.5x46x352±12/±159-40/15-36/32-74/66-154-40 up to +8553AVPJsp103.5x46x2515/12/15/24/309-40/15-36/32-74/66-154-40 up to +8575AVPK90.5x65.5x3513.3/5/12/15/24/305-36/9-40/15-36/32-74/43-101/66-154-40 up to +85• Vibration resistant and indifferentto humidity due to encapsulatedcasemax. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)Input Voltage Ranges (VDC)Operating Temperature in °C78AVPKsp103.5x46x3513.3/5/1215/24/305-36/9-40/15-36/19-51/32-74/43-101/66-154-40 up to +85For complete data sheetsvisit www.autronic.de


DC-DC ConvertersAVP-SeriesChassis MountingAVP/KE-FAVP/Js AVP.../Ks (AVP-3/KEP-F)AVP/KEP-FChassis Mounting• Isolated• Single, dual, bipolar and tripleoutput• CE marked• Burst transients according toEN 61000-4-4• Surge according to EN 61000-4-5• Conducted immunity according toEN 61000-4-6• Electrostatic discharge accordingto EN 61000-4-2• Conducted RFI:max. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)Input Voltage Ranges (VDC)Operating Temperature in °Cmax. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)36AVP-3Ks113x46x353+5, ±12/+5, ±159-40/15-36/32-74/66-154-40 up to +8578AVPKs113x46x3513.3/5/12/15/24/3047AVP-2D/Ks113x46x3525, 12/5, 159-40/15-36/32-74/66-154-40 up to +8587AVP-3KEP-F200x49x1123+5, ±12/+5, ±1551AVP-2B/Ks113x46x352±12/±159-40/15-36/32-74/66-154-40 up to +8587AVP-3KEP-C200x39x1123+5, ±12/+5, ±1553AVPJs113x46x2515/12/15/24/309-40/15-36/32-74/66-154-40 up to +85100AVPKE-F200x49x11215/12/15/24– Input filtering according toEN 55022• According to Railway StandardEN 50155 and EN 50121-3-2• Case option C: for chassis mountingon power loss dissipating metalsurface (heat sink)• Case option F: for chassis mountingon no power loss dissipatingsurfaceInput Voltage Ranges (VDC)Operating Temperature in °Cmax. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)5-36/9-40/15-36/19-51/32-74/43-101/66-154-40 up to +85100AVPKE-C200x39x11215/12/15/2415-36/32-74/66-154-40 up to +85200AVPKEP-F200x64.6x112112/15/2415-36/32-74/66-154-40 up to +85200AVPKEP-C200x43.6x112112/15/249-40/15-36/19-51/32-74/43-101/66-154-40 up to +85Input Voltage Ranges (VDC)Operating Temperature in °C9-40/15-36/19-51/32-74/43-101/66-154-40 up to +8515-36/19-51/43-101/66-154-40 up to +8515-36/19-51/43-101/66-154-40 up to +85For complete data sheetsvisit www.autronic.de


AVP-SeriesStandard euro-rack size 19“AVP/KE(AVP-3/KEP)AVP/KE-S(AVP-3/KEP-S...)AVP/KEPConverter Card(Assembly example)Standard euro-rack size 19“• Isolated• Single, dual and triple output• CE markedmax. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)87AVP-3KEP190x40.2x1123+5, ±12/+5, ±1587AVP-3KEP-S|SB167.7x50.4x1123+5, ±12/+5, ±15• Burst transients according toEN 61000-4-4• Surge according to EN 61000-4-5Input Voltage Ranges (VDC)Operating Temperature in °C15-36/32-74/66-154-40 up to +8515-36/32-74/66-154-40 up to +85• Conducted immunity according toEN 61000-4-6• Electrostatic discharge accordingEN 61000-4-2• Conducted RFI:– Input filtering according toEN 55022• According to Railway StandardEN 50155 and EN 50121-3-2max. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)Input Voltage Ranges (VDC)Operating Temperature in °C100AVPKE190x40.2x11215/12/15/249-40/15-36/19-51/32-74/43-101/66-154-40 up to +85100AVPKE-S167.7x50.4x11215/12/15/249-40/15-36/19-51/32-74/43-101/66-154-40 up to +85200AVPKEP169.4x70.7x112112/15/2415-36/19-51/43-101/66-154-40 up to +85• Zero load operation and shortcircuit protection• Overtemperature shutdown• Remote off (inhibit) withTTL - L-signal• Overvoltage protection in theoutput circuit, even in case ofexternal supply (OVP)• Reverse polarity protection byinternal fusemax. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)Input Voltage Ranges (VDC)Operating Temperature in °C200Converter CardQD100x1604dependingon modeldependingon modeldependingon model200Converter CardMD100x1601-3dependingon modeldependingon modeldependingon model200Converter CardPD100x1601dependingon modeldependingon modeldependingon model200Converter CardSD100x1602dependingon modeldependingon modeldependingon model• Fully integrated heatsink providesextremely low thermal stress totemperature sensitive components• Yellow LED to indicate operatingmode• Coated assembly• Coated and glued parts for bettervibration resistance• Case option S: for sub racks withclosed backplane• Case option SB: for sub racks withclosed backplane, metal sheetinstead of front panel• Frontplate 8 HP, 10 HP and14 HP/3U (see table)For complete data sheetsvisit www.autronic.de


Qone-SeriesStandard euro-rack size 19“ / Chassis MountingQone HEC-4/DBQone LECQone LEC-CQone LEC-CSStandard euro-rack size 19“Qone HEC-4 for Compact PCI• Isolated• Quad outputmax. Output Power (W)TypeCaseDimensions (LxWxH) in mmOutputsOutput Voltages (VDC)100QoneHEC-4DB166.5x40.3x1114+3.3/+5/+12/-12160QoneLEC164.5x20x11115/12/24160QoneLEC-C162x19,2x11115/12/24160QoneLEC-CS119x19,2x11115/12/24• Front plate 8 HP / 3 U• High power density• Overtemperature and overvoltageshutdownInput Voltage Ranges (VDC)Operating Temperature in °C14.4-36/19-51/43-101/66-160-40 up to +8514-36/9-40/21-51/43-101/64-160-40 up to +8514-36/9-40/21-51/43-101/64-160-40 up to +8514-36/9-40/21-51/43-101/64-160-40 up to +85• Short circuit protection• Remote on/off• Coated assembly• Glued parts for better vibrationresistance• Fixed switching frequency• Yellow LED to indicate operatingmode• According to Railway StandardEN 50155 and EN 50121-3-2• Inrush current limiting• Reverse polarity protection• Hold up time of 10 ms• Supply fail• Derating signal• Sense• Enable signalQone LEC• Isolated• Single• Front plate 4 HP / 3 U (LEC)• CE marked• High power density• Overtemperature and overvoltageshutdown• Short circuit protection• Remote on/off• Coated assembly• Glued parts for better vibrationresistance• Fixed switching frequency• Yellow LED to indicate operatingmodeFor complete data sheetsvisit www.autronic.de


DC-DC ConvertersSpecial SolutionsHFBC-3W/0Solution with ACR45Custom-specific boosterSpecial SolutionsWe are the right people to talkabout particular requirements. Wewill develop and produce your ownspecial converter.Examples:• HFBC-3W/O:– Triple output– Output power up to 43 Watts– Ultra wide input range- Wide temperature range– Hold up time of 20ms– According to RIA12 (A to G)– According to EN 50155Inquiry by fax +49 (0) 7147/24 -252Company:First Name:Street:Zip Code:Country:Telephone:Email:Date:Last Name:PO Box:City:Fax:• Solution with ACR45:– Dual output– Additional surge protection– Active reverse polarity protection– Integrated heat sink– Hold up time of 10ms– According to EN 50155Output VoltagesInput VoltagesOutput Currents• Custom-specific booster:– Output power 375W/25A– Wide input range: 8-24V– Output voltage up to 15Vwith sense function– High efficiency throughsyncron-rectifier– Suitable for fuel-cellIsolationConstruction/MountingTemperature RangeQuantity/Delivery ScheduleRemarksFor complete data sheets,visit www.autronic.de


For complete data sheetsvisit www.autronic.deOther types on request.Specifications subject to change without notice.AUTRONIC Steuer- undRegeltechnik GmbHPostfach 1280D-74338 SachsenheimTel.+49 (0) 71 47 / 24-200Fax+49 (0) 71 47 / 24-252http://www.autronic.dee-mail: vertrieb@autronic.deQUALITY SYSTEMcertified by DQS according toDIN EN ISO 9001: 2008 Reg.-No. 000510QM08/2010