HEARTH EXTENSION:A hearth extension is required to protect the combustible floorconstructed in front of the fireplace. The hearth extension isnot included and must be fabricated. The hearth extensionmust project at least 12 inches beyond each side of thefireplace opening (see drawing on front cover).Figure 6AIR KIT <strong>INSTALLATION</strong>CAUTION: AIR DUCTS MUST NOT TERMINATEIN ATTIC SPACE OR GARAGE.Figure 5HEARTH EXTENSIONSThe hearth extension must be made of non-combustible,inorganic material having an effective thermal conductivity“K” of 0.84 BTU IN/FT.HR.F (or less) at 1 inch thick.Thermal conductivity “K” of materials can be obtained fromthe manufacturer of the non-combustible material. Theminimum required thickness for any material could beobtained by the following formula:K factor at 1 inch = thickness required0.84For example, if the material selected has a K factor of 0.25,such as a glass fiber, the following formula would apply:Avoid installing outside air eyebrow in areas where inletopening may be blocked by snow, bushes or other obstacles.It should also be located beyond the reach of children. Themaximum height of air inlet above platform of fireplace is 3 ft.below the termination flue gas outlet.For further details on the installation of the outside air kit,please refer to the instructions included with the air kit. Foroperating instructions please refer to your owner’s manual.The outside air handle is located inside the face opening,above the upper left top of the rear firebrick (see figure 7).Push the rod up to open the air intake and push down to closeit. Always open the mechanism when starting a fire to provideadequate outside combustion air. Close the mechanism whennot in use to prevent cold air from entering the room.0.25 = 0.30 thickness required0.84If the hearth extension is to be covered, use non-combustiblematerial such as tile, slate, brick, concrete, metal, glass,marble, stone etc. Provide a means to prevent the hearthextension from shifting and seal the gap between the fireplaceframe and hearth extension with a non-combustible material(see figure 5).WARNING: HEARTH EXTENSION IS TO BEINSTALLED ONLY AS DESCRIBED.Figure 7AIR KIT DAMPER RODOPTIONAL OUTSIDE AIR KIT (MODEL AK4E):The outside air kit must be installed during the rough framingof the fireplace due to the nature of its location. Outsidecombustion air can be accessed through an exterior wall. Seefigure 6 and Accessories on page 11.GAS LINE <strong>INSTALLATION</strong> (OPTIONAL):Gas line hook up should be done by your supplier or aqualified service person.NOTE: Before you proceed, make sure your gas supply isturned off.4 For more information, visit www.desatech.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!