12.07.2015 Views

Model W-800 UV Oil in Water Analyzer - OrbInstruments.com

Model W-800 UV Oil in Water Analyzer - OrbInstruments.com

Model W-800 UV Oil in Water Analyzer - OrbInstruments.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Model</strong> W-<strong>800</strong><strong>UV</strong> <strong>Oil</strong> <strong>in</strong> <strong>Water</strong><strong>Analyzer</strong>On-l<strong>in</strong>e <strong>UV</strong> <strong>Oil</strong> <strong>in</strong> <strong>Water</strong> <strong>Analyzer</strong> forthe cont<strong>in</strong>uous measurement of oils <strong>in</strong>water process streams Operat<strong>in</strong>g range 0-100 ppm Rapid analysis cycle of 15 seconds or less Excellent repeatability to 0.5ppm or less Full color display with cont<strong>in</strong>uous runn<strong>in</strong>gchart Compact design with separate enclosures forelectronics and analytics No sample condition<strong>in</strong>g necessary No support<strong>in</strong>g chemicalsThe <strong>Model</strong> W-<strong>800</strong> <strong>Oil</strong> <strong>in</strong> <strong>Water</strong> <strong>Analyzer</strong> is a result of <strong>com</strong>b<strong>in</strong><strong>in</strong>g the latest, state of the art technology with over 20 yearsof experience servic<strong>in</strong>g and build<strong>in</strong>g on-l<strong>in</strong>e analyzers. This unit utilizes a measurement chamber with a <strong>UV</strong> lightsource, which reacts with oils <strong>in</strong> water to determ<strong>in</strong>e the concentration of soluble oils without the use or consumptionof support<strong>in</strong>g chemicals.This cost-efficient design provides very simple, yet rugged construction. The W-<strong>800</strong> demonstrates the perfection ofon-l<strong>in</strong>e water measurements by hav<strong>in</strong>g rapid measurement cycle without limit<strong>in</strong>g accuracy, repeatability or reliability.


APPLICATIONWith grow<strong>in</strong>g public awareness and concern for controll<strong>in</strong>g water pollution and enactment of the Clean <strong>Water</strong> Act<strong>in</strong> 1972 (amended <strong>in</strong> 1977) it has be<strong>com</strong>e <strong>in</strong>creas<strong>in</strong>gly important to cont<strong>in</strong>uously monitor the quantity of effluents<strong>in</strong> waste water prior to discharge. F<strong>in</strong>d<strong>in</strong>g a method of accurately obta<strong>in</strong><strong>in</strong>g results <strong>in</strong> a cost effective manner hasplagued <strong>in</strong>dustrial <strong>com</strong>panies for years due to the nature of the chemistry <strong>in</strong>volved.The development of photometric and spectroscopic techniques has proved an <strong>in</strong>valuable tool <strong>in</strong> the applicationof on-l<strong>in</strong>e effluents monitor<strong>in</strong>g. The removal of hazardous solutions and high temperature applications coupledwith fast response and high accuracy has brought the use of photometric correlation techniques to the forefrontof waste and process water monitor<strong>in</strong>g.COMPARISON OF ORGANIC MEASUREMENT METHODSParameters254 nm <strong>UV</strong>FlourescenceExtraction withIR AbsorptionStripp<strong>in</strong>g with FIDResponse Time< 15 sec.> 5 m<strong>in</strong>.> 5 m<strong>in</strong>.Detection of TotalHydrocarbonsNo(only aromatics)YesYesFilter<strong>in</strong>gInstallation TimeNoneM<strong>in</strong>utesRequired forWaste <strong>Water</strong>HoursRequired forWaste <strong>Water</strong>HoursMa<strong>in</strong>tenance &OperationEasyHardHard<strong>Analyzer</strong> CostLowHighHighChemical UsageNoneYesNoneGas UsageNoneNoneYes


OPERATING PRINCIPLEThe W-<strong>800</strong>’s measurement cycle is based a <strong>UV</strong> light source react<strong>in</strong>g with the oils to cause fluorescence which isthen detected and measured.The sample is constantly flow<strong>in</strong>g through a quartz cell (a peristaltic pump option is available for non-pressurizedsample to provide flow).The operat<strong>in</strong>g pr<strong>in</strong>cipal quantifies the concentration of oil based on the fluorescence <strong>in</strong>tensity measured by aphoto-multiplier tube located perpendicular to the <strong>UV</strong> light path. An auto-zero feature allows the analyzer to adjustfor turbidity, slow foul<strong>in</strong>g or deterioration of light sources by resett<strong>in</strong>g the basel<strong>in</strong>e of the full light <strong>in</strong>tensity. Thef<strong>in</strong>al concentration calculation is correlated to the florescence <strong>in</strong>tensity of the sample based on a programmablecorrelation chart, which can be customized by the end-user.To further enhance the overall performance of the system, multi-band options are available to give the analyzer abroad measurement range.The W-<strong>800</strong> <strong>UV</strong> <strong>Oil</strong> <strong>in</strong> <strong>Water</strong> <strong>Analyzer</strong> can be used to monitor multiple streams via external stream switch<strong>in</strong>g.Sample test results may be sent to any one of four (4) locations by switch<strong>in</strong>g the output Stream Sett<strong>in</strong>g(correspond<strong>in</strong>g with the four (4) signal relays at the back of unit).DIMENSIONS<strong>in</strong>ch (mm)9.500 (241)2.000(51)CUSTOMER CONNECTIONS1-45.000(127)2.000(51)POWER IN13.25(337) 8.000(203)2.000(51)SAMPLE RETURN18.250(464)24.500(622)22.000(559)20.250(514)18.750(476)17.000(432)2.000(51)4.250(108)SAMPLE INLET13.50(343)CALIBRATION SAMPLEIN4.250(108)15.500(394)


PRODUCT GUIDEPetroleum <strong>Analyzer</strong>s•Flash Po<strong>in</strong>t•Salt In Crude•RVP•RVP/VL20•Freeze Po<strong>in</strong>t•Cloud Po<strong>in</strong>t•Pour Po<strong>in</strong>t•Viscosity•Viscosity Index<strong>Water</strong> <strong>Analyzer</strong>s•<strong>UV</strong>-COD•<strong>UV</strong>-<strong>Oil</strong> <strong>in</strong> <strong>Water</strong>Other Products•Environmental Cab<strong>in</strong>ets•Sample Condition<strong>in</strong>gSystems•Sample RecoverySystems•Spare Parts<strong>Analyzer</strong> Services•Field Service•Start-Ups•Tra<strong>in</strong><strong>in</strong>g•Technical SupportSPECIFICATIONS: W-<strong>800</strong> <strong>UV</strong> OIL IN WATER ANALYZERANALYSIS PERFORMANCEMeasurement Cycle TimeMeasurement RangeRepeatabilityAccuracySAMPLE REQUIREMENTSSample Bypass Flow RateSample PressureSample TemperatureENCLOSURE/INSTALLATION REQUIREMENTSDimensions15 seconds or less0-100 ppm± 0.5 ppm)± 10% of full scale0-5 l/m<strong>in</strong>0-50 psi (0-3.5 bar)5-95°CWidth 16 <strong>in</strong> (406mm)– Height 25 <strong>in</strong> (635mm) – Depth 10 <strong>in</strong> (254mm)Weightapproximately 60 lbs (27 kg)Operat<strong>in</strong>g Temperature5-40°C (41°F-104°F)Enclosure Material/Rat<strong>in</strong>gsta<strong>in</strong>less steel - NEMA 4X / IP65Area Classification optional NEC Class 1 Div 1 Group C + D or ATEX Zone 1 Group IIPower100 to 240 VAC (± 10%), 50/60 Hz, s<strong>in</strong>gle phase, 2APurge Gas Supply, optionalClean, dry Nitrogen (better than 98% pure) or other <strong>in</strong>ert gas at M<strong>in</strong>. 80 psi (5.5 bar)– Max. 100 psi (6.8 bar) / expected leakage <strong>com</strong>pensation 1l/m<strong>in</strong>END USER CONNECTIONSAnalog Stream Switch<strong>in</strong>g Outputend-user programmable analog output from one of four relay signals (12 or 24 VDCouput)s<strong>in</strong>gle isolated 4-20 mA output (optional second output - selectable for sampleAnalog Output Signalconcentration, analyzer system warn<strong>in</strong>g or analysis measurement <strong>in</strong>dication)Relay Output ContactSerial Input/Output SignalHOW TO ORDERANALYZER SYSTEMSCatalog Number W-<strong>800</strong>-110Catalog Number W-<strong>800</strong>-1200Catalog Number W-<strong>800</strong>-1300OPTIONSCatalog Number 700236Catalog Number 700446ACCESSORIESCatalog Number 700447Catalog Number 700448two (2) SPDT relays with contacts rated at 3A resistive load at 250VAC , selectable forsample concentration alarm, analyzer system warn<strong>in</strong>g or analyzer system shutdownalarmoptional second analog output signal (12 or 24 VDC output)ORB <strong>Model</strong> W-<strong>800</strong> <strong>UV</strong> <strong>Oil</strong> <strong>in</strong> <strong>Water</strong> <strong>Analyzer</strong>, Ex Area ready for NEC Class 1 Div 1 Group C + DORB <strong>Model</strong> W-<strong>800</strong> <strong>UV</strong> <strong>Oil</strong> <strong>in</strong> <strong>Water</strong> <strong>Analyzer</strong>, Ex Area ready for ATEX Zone 1 Group IIORB <strong>Model</strong> W-<strong>800</strong> <strong>UV</strong> <strong>Oil</strong> <strong>in</strong> <strong>Water</strong> <strong>Analyzer</strong>, for General Purpose AreaPeristaltic Pump for non-pressurized sampleSecond Analog Output (2-20mA)1-Year Spare Parts Kit2-Year Spare Parts KitLit. No. W-<strong>800</strong>-EN-US / JAN10ORB Instruments, Inc.4724 South ChristianaChicago, IL 60632 / USAPhone: + (1) 773 927-8600Fax: + (1) 773 927-8620Email: sales@orb<strong>in</strong>struments.<strong>com</strong>www.orb<strong>in</strong>struments.<strong>com</strong>This publication is not <strong>in</strong>tended to form the basis of a contract. The <strong>com</strong>pany reserves the right to change design and specification of its products without notice.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!