4 - Installation4.1 Transport4.2 UnpackingNOTE: Transport the UPS only in upright position. Check for sufficient floor and elevation loadingcapacity. Move the UPS in its original package to the final destination room. Do not stack otherpackage on top.Cut the two wrapping bands, and remove the shipping box. Loosen the four bolts with which the UPS is fixed tothe pallet. Remove the UPS from the pallet.BE CAREFUL! Pay attention to the HEAVY WEIGHT of the UPS when downloading the UPSfrom the pallet! Never try to lift the unit by yourself!The UPS is equipped with castors, which allow easy displacement of the unit. Please take appropriatemeasures to avoid damage on vulnerable floors.4.3 Package ContentsThe shipping box contains a LP 11 UPS, a CD-ROM, an RS232 cable, cable clamps, a safety guide and thismanual. If the UPS is equipped with an RPA plug-in card (Redundant Parallel Architecture, right option slot atthe rear of the unit) the shipping box also contains a yellow network cable and one bus terminator. Inspect theUPS for damage after unpacking. If any damage is present please notify the carrier and place of purchaseimmediately.4.4 LocationPlease refer to sections 1.2 and 1.3 of ‘IMPORTANT SAFETY INSTRUCTIONS’.4.5 InstallationIMPORTANT:Before making any connection and switching on the LP UPS, please check the following conditions:- the voltage and frequency of your utility supply is 220/230/240 Vac and 50/(60) Hz; off-factory the outputof the UPS is set to 230 Vac / 50 Hz,- the branch circuit supply is protected as follows:UPS modelLP 3kVALP 5/6kVALP 8kVALP 10kVAbranch protection16A slow25A slow50A slow50A slowTable 1. external input fuse valueCAUTION: To reduce risk of fire, connect the UPS only to a circuit provided with the fusevalues according to Table 1 above.- Ensure that the total power requirement of the equipment to be protected does not exceed the ratedoutput power of the UPS (output power for your unit is indicated on the rating label on the rear panel).- The UPS must be grounded when in use: Connect the UPS to a single phase, three wire AC sourceequipped with an earth connection.The following sections describe the installation of the LP 11 UPS.LP 3/5/6-11 UPS: 4.5.1 and 4.5.2LP 8/10-11 UPS: 4.5.3 and 4.5.4LP 11 UPS, general: 4.5.5OPM_LPE_11X_3K0_10K_1GB_V041 8 GE DE LP 11 UPS: User manual 4.1 (GB)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!