12.07.2015 Views

Operation Manual - ASSMANN IT-Solutions AG

Operation Manual - ASSMANN IT-Solutions AG

Operation Manual - ASSMANN IT-Solutions AG

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

UPS Type : LP 3-11 LP 5-11 LP 6-11 LP 8-11 LP 10-11AUTOMATIC BYPASS SW<strong>IT</strong>CHThe automatic switch provides transfer of the load to the mains voltage without any interruption of the supply. The transfer isinitiated by a signal from the output converter protection circuit in case of an overload or high temperature.When the conditions return to normal the load is automatically transferred back to the output converter. The automaticbypass switch can be disabled by the end-user.Bypass voltage limits : ±10% of nominalTransfer transients : typically 2% mean deviation over one half cycle.Frequency tracking range : ± 2/4/6% of nominal (user selectable)Slew rate : max. 1Hz/sec or 5Hz/sec (user selectable)BATTERYBattery type : Sealed and maintenance freeNominal voltage (V) / capacity (Ah) : 12/7 12/7 12/7 12/12 12/12Number of batteries : 12 20 20 20 20Capacity of standard battery set : 7 Ah 7Ah 7Ah 12Ah 12AhBattery recharge time : 1.5 - 3 hours for 80% capacityBattery service life : up to 6 years (depending on operating conditions)Battery discharging : self discharge current 0.35 mAdischarge end voltage of the battery depending on the actual load10.5Vdc < 0.2 CA till 9.0 Vdc > 2 CAWhen the LP-11 is in sleeping mode the inverter will be switched off, batterycharger and rectifier are in operationRuntime in minutesVA / Watts1000 / 800 : 30 60 60 120 1202000 / 1600 : 15 40 40 60 603000 / 2400 : 10 18 18 40 405000 / 4000 : - 10 10 22 226000 / 4800 : - - 8 17 178000 / 6400 : - - - 11 1110000 / 8000 : - - - - 8BATTERY EXTENSION PACKSSheet steel cubicle : VSDA1Dimensions (hxwxd, mm) : 537x313x590Battery : 240Vdc/7Ah or 240Vdc/14AhWeight with battery : 70kg or 120kg (without batt: 20kg)Battery pack A (voltage V / capacity Ah) : n.a. 240/7 240/7 240/7 240/7Total capacity (Ah) : n.a. 14 14 19 19Typical runtime, 100% / 50% load, min. : n.a. 25/60 21/50 22/50 16/39Number of packs required : n.a. 1 1 1 1Extension B (voltage V / capacity Ah) : n.a. 240/14 240/14 240/14 240/14Total capacity (Ah) : n.a. 21 21 26 26Typical runtime, 100% / 50% load, min. : n.a. 45/90 35/75 33/70 25/57Number of packs required : n.a. 1 1 1 1For more info see section 7.1ENCLOSURESheet steel cubicle : VSD1 VSD1 VSD1 VSD2 VSD2Colour front : aluminumColour cabinet : RAL 9010 (white)Protection : IP 20Dimensions (hxwxd, mm) : 537x313x590 537x313x590 537x313x590 680x313x720 680x313x720(height with castors)Weight (with batteries) : 85kg 110kg 115kg 165kg 170kgGENERAL DESIGN CR<strong>IT</strong>ERIAMechanical : IP20Humidity : 95% non condensingSafety : EN 50091-1; EN 60950; IEC 950EMC : EN 50091-2Surge capability : IEC 1000-4-5 (6kV 1.2/50µs, 3kA 8/20µs)OPM_LPE_11X_3K0_10K_1GB_V041 34 GE DE LP 11 UPS: User manual 4.1 (GB)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!