12.07.2015 Views

Operation Manual - ASSMANN IT-Solutions AG

Operation Manual - ASSMANN IT-Solutions AG

Operation Manual - ASSMANN IT-Solutions AG

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

9 - TroubleshootingWhenever a malfunction occurs, first check external factors (e.g. connections, temperature, humidity or load) todetermine whether the problem is caused by the unit itself or by its environment. Subsequently check whetherthe MCB/switches on the rear panel (fig. 12, 7-8-9) are in ‘on’ position. Always check these external factorsbefore concluding that your UPS is faulty.The front screen will indicate the problem and solution (if the problem is due to environmental circumstances). Ifthe solution is not shown on the screen, please contact your dealer.During the self-test, performed immediately after start-up, the UPS may detect a system failure. In this case amessage is displayed for 30 seconds before the self-test is repeated. If the faulty situation persists, pleasecontact your dealer.(One of) the following messages can be displayed:SELFTEST FAILUREPCB POWER SUPPLYSELFTEST FAILUREAC ON INPUTOne or more voltages of the internal power supply is (are) outsidetolerance. Please contact your dealer.An external AC voltage (not the UPSs output voltage) was detected on theoutput terminals. Please contact your dealer.SELFTEST FAILUREINT.BATTERY FUSESELFTEST FAILUREEXT.BATTERY FUSEThe internal battery fuse is defective. Please contact your dealer.The battery extension circuit breaker is in 'the off' position. Please switch itto 'the on' position.SELFTEST FAILUREBATTERY CHARGERSELFTEST FAILUREUic TOO HIGHMalfunction of the battery charger. Please contact your dealer.Malfunction of the input circuit: voltage delivered is too high. Please contactyour dealer.SELFTEST FAILUREThe temperature of (one of) the components is (still) too high.TEMP TOO HIGH See section 5.3.2.SELFTEST FAILUREUba TOO LOWThe battery voltage is too low to allow start-up. Wait for a few hours, leavethe UPS switched on.*SELFTEST FAILUREUic TOO LOWMalfunction of input circuit: voltage delivered is too low. The batteries maybe faulty or depleted. Wait for a few hours, leave the UPS switched on.*SELFTEST FAILUREQ4 NOT OKHardware output voltage detection 'Q4' is active.* If absence of input power (utility failure, maintenance work) is expected to last longer than a few hours, switchoff the UPS to save battery power. If the UPS input power is absent for several days and the UPS remains onunder no-load conditions, the batteries can be discharged very deeply, resulting in a short battery life time.OPM_LPE_11X_3K0_10K_1GB_V041 32 GE DE LP 11 UPS: User manual 4.1 (GB)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!