12.07.2015 Views

TotalCare Duo2 Brochure EN - Hill-Rom

TotalCare Duo2 Brochure EN - Hill-Rom

TotalCare Duo2 Brochure EN - Hill-Rom

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Products<strong>TotalCare</strong> Duo TM 2 Therapy SystemA unique combinationfor the highly dependent patientwhich revolutionisesthe caregiver environment.


<strong>TotalCare</strong> Duo TM 2 Therapy System<strong>TotalCare</strong> Duo TM 2 Therapy System offers acombination of frame and surface that makescaring for the most vulnerable patients,easier and safer.At a glance:• Ergonomically designed forcaregiver efficiency.• Promotes patient mobility to helpimprove patient outcomes.• Provides highly effective woundprevention and therapy.• Advanced functions for safer mobilisation.• Assures patient comfort and safety.The ergonomically designed frame with one buttonFullChair TM and Chair Egress TM positions, promotespatient mobility, earlier rehabilitation and greaterindependence. At the same time, the uniqueDuo ® 2 advanced low-pressure surface providespressure relief and comfort, in any position.<strong>TotalCare</strong> Duo TM 2 Therapy System is suitable forpatients with or at risk of skin damage includingburns, pressure sores, plastic surgery and many otherconditions.This winning combination of positioning and pressurerelief makes a real difference to both patients andcaregivers. By reducing the need for manual lifting andhandling, <strong>TotalCare</strong> Duo TM 2 Therapy System increasescaregiver efficiency and improves patient outcomes.


ProductsDuo ® 2 TherapyLine of site ControlsTMAngle IndicatorsIndependentHead ZoneOneStep TM Side railRelease MechanismRemovable Headboardfor CPR SupportCentralPoint-Of-Care TM AreaPatientControlsCollapsibleTransport HandlesBody Zonewith microcushionsforthe lumbarWallGuard TMBumper SystemBrake andSteer SystemHandsFree TM EmergencyCPR & TrendelenburgRelease MechanismManualFoot PedalIndependentReal-Heel TM Zonewith microcushionsDrainage BagHolders15.2 cm diametercasters


The ultimate support systemfor managing yourhighly dependent patients.


ProductsThe integral Duo ® 2 support surface offers twoclinically accepted therapies in one proven product.Duo ® 2 has a unique pressure control technologycalled De-Teq ®De-Teq ® constantly monitors the patient’s weight andposition providing the lowest possible pressures to optimisepressure relief for all patients in all positions, thus ensuringa high TCPO 2at all times even in high risk patients.Continuous modeAlternating modeAir in or outThe unique Real-Heel TM zone, with its optimised1 in 2 cycle and its 12 micro-cushions, adjustsindependently to the body zone.Air pressureDistanceAirProtex TM coverSensing zoneThe fully enclosed Protex TM mattress cover is easilycleaned. It is smooth, waterproof, moisture vapourpermeable and bacteriostatic. The two way stretchmaterial conforms to the patient’s body shape andreduces friction and shear.HandsFree TM featuresHandsFree TM emergency CPR and Trendelenburg releasemechanism for instant care, even from the FullChair TMposition. Once activated, the one step CPR functionmodifies the bed position and deflates the mattresswithin 10 seconds.Shearless Pivot TM Patient Position MechanismThe unique mechanism combining the articulationof the frame and the surface minimises shear forces,reducing migration of the patient towards the footof the bed. Repositioning is minimised and patientcomfort maximised.Transport modeTransport mode allows patient support for two hours.Simply unplug the bed power supply and silencethe alarm.Protex TM mattress coverShearless Pivot TMHandsFree TM CPRTransport mode


The <strong>TotalCare</strong> Duo TM 2 Therapy System isdesigned for the caregiver,head to foot.


ProductsFullChair TM Patient Position Mechanismand Chair Egress TM PositionUsing one-button chair positioning, a single caregivercan place the patient in a chair position, providingan ideal position to:• enhance respiratory mechanics• ease nutritional difficulties• improve psychological statusthereby effectively accelerating their rehabilitation.By removing the footboard, the caregiver can aid thepatient to weight bear or egress the bed reducingthe risk of injury. Safe, simple and effective.Point-of-Care TM side rail controlsFullChair TM Patient PositionAll controls, information and alarm systems areconveniently placed around the Point-of-Care TMby the patient’s side. The OneStep TM design side railscan be released using a single hand, tucking awayto allow unrestricted access to the patient and a zerotransfer gap. The optional Patient Weigh Scale andbed exit alarm can also be consulted from thePoint-of-Care TM side rail controls.FlexAfoot TM Retractable Foot MechanismThe foot section of bed and surface can be retractedand extended in both chair and supine positions toprovide support for the patient’s feet or to facilitatetransport in small spaces.Chair Egress TM PositionFlexAfoot TM RetractableFoot MechanismAdjustable heightOneStep TM side railsPatient ControlsThe integrated, easy-to-usepatient controls promote patientindependence in positioning, allowingthe caregiver more time for skilled tasks.


Products<strong>TotalCare</strong> Duo TM 2 Therapy SystemTechnical DataFRAME SPECIFICATIONSWIDTHSide rails up: .........................................................................101.6 cmSide rails down: ..................................................................... 91.4 cmL<strong>EN</strong>GTHWithout bumpers: ................................................................233.7 cmWith bumpers: .....................................................................237.5 cmFOOT RETRACTION:..............................................................30.5 cmRADIOLUC<strong>EN</strong>T WINDOWLength x width: ......................................................58.4 cm x 55.9 cmHEIGHT OF SIDE RAILAbove mattress:......................................................................> 22 cmAbove deck:..........................................................................37.47 cmCHAIR POSITIONINGChair Position:50º - 65º ................................................................................ Head0º - 10º ....................................................................................Seat30º - 70º ..................................................................................FootChair Egress TM Position:65º - 75º ................................................................................ Head0º - 10º ....................................................................................Seat70º - 85º ..................................................................................FootBED ARTICULATIONTrendelenburg/Reverse-Trendelenburg: .......................................15º/15ºEmergency Trendelenburg: ........................................................... 20ºHead Section: ................................................................................ 75ºKnee: ............................................................................................ 20ºAutomatic Contour: ...................................................................... 10ºCASTER SIZE: ........................................................................15.2 cmHEIGHTMinimum height:....................................................................44.5 cmMaximum height: ...................................................................92.7 cmWHEELBASE: ......................................................................106.7 cmWHEELTRACKHead: .....................................................................................65.4 cmFoot: ......................................................................................59.7 cmUNDERBED CLEARANCE: .....................................................12.1 cmSCALECompliant with <strong>EN</strong>45501.................................................. classAccuracy:5 kg - 25 kg.............................maximum permissible error +/- 0.25 kg25.5 kg - 100 kg........................maximum permissible error +/- 0.5 kg100.5 kg - 200 kg....................maximum permissible error +/- 0.75 kgWeighing Capacity:...................................................................200 kgMaximum working load frame: .............................................226.8 kgTHERAPY SURFACE SPECIFICATIONSMATTRESS:Length (inflated): ........................................................ 182 - 212 cmWidth (inflated): ......................................................................85 cmTotal height (inflated in Therapy mode): ...............................13.5 cmCOVER MATERIAL:Protex TM (polyurethane coated in knitted nylon)ELECTRICAL REQUIREM<strong>EN</strong>TS:Voltage: ..................................................................AC 230 V, 50 HzCURR<strong>EN</strong>TRated: .................................................................................. 650 mANormal: ................................................................................ 350 mAStand-by: ............................................................................. 300 mAPower consumption: ................................................................ 80 WMAXIMUM PATI<strong>EN</strong>T WEIGHT:Maximum acceptable patient mass with clinical efficacy for any headof bed elevation excluding bed necessities and accessories: ... 150 kg0459www.hill-rom.comFrance .......................................+33 (0)2 97 50 92 12United Kingdom .......................+44 (0)1530 411000Deutschland .............................. +49 (0)211/16450-0Nederland .................................+31 (0)347 32 35 32Italia ................................................. +39 02-950541Class IIa Medical device in accordance with the Directive 93/42/EEC.Suisse/Schweiz .................... +41 (0)21/706 21 30(deutschsprachig) ............................021/706 21 38Österreich ........................... +43 (0)2243 / 28550Ireland .................................. +353 (0)1 413 6005Iberia ..................................... +34 (0)93 6856000NOISE LEVEL:Below 65 dB (A) without mattress system active @ 1 metre.Below 3 dB (A) above ambient noise with mattress system active @ 1 metre.Nordic Countries .......................+46 (0)8 564 353 60Export ..............contact your local <strong>Hill</strong>-<strong>Rom</strong> distributor....................or contact your Area manager via website.............................................. or call +1 812 934 8173Design: www.cadmium.fr PB <strong>TotalCare</strong> Duo TM 2 Therapy System V.001 - 02/05 E.<strong>Hill</strong>-<strong>Rom</strong> reserves the right to make changes without notice in design, specifications and models. The only warranty <strong>Hill</strong>-<strong>Rom</strong> makes is the express written warranty extended on the sale or rental of its products.© 2005 <strong>Hill</strong>-<strong>Rom</strong> S.A.S. - ALL RIGHTS RESERVED.USA & CanadaWestern & Eastern EuropeMiddle East / Africa /Sub Indian ContinentAsia Pacific