12.07.2015 Views

Always flush all new filter cartridges at time - Clean My Water

Always flush all new filter cartridges at time - Clean My Water

Always flush all new filter cartridges at time - Clean My Water

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

XS1B Aircraft W<strong>at</strong>er FilterPart No. 9410-00FAA-PMA APPROVEDPremium quality w<strong>at</strong>er filtr<strong>at</strong>ioncre<strong>at</strong>ed for use in Aircrafts.INLET AND OUTLET CONNECTIONSBottom IN / Bottom OUT Top VentInlet and Outlet:9/16”–18NF (3/8” tube union)REPLACEMENT CARTRIDGES• All D-Clor <strong>cartridges</strong> remove taste and odors while <strong>filter</strong>ingout dirt and suspended m<strong>at</strong>ter. See chart belowfor different pressure drop characteristics.• In addition to removing taste and odors, the 150GPcartridge inhibits limescale build-up. Limescale preventionis particularly important in applic<strong>at</strong>ions involvinghot w<strong>at</strong>er he<strong>at</strong>ers and coffee makers.XS1B AssemblyP/N 9410-00 (1 pack)BENEFITS• Improves aircraft w<strong>at</strong>er by removing chlorineand other off tastes and odors• Filters out dirt and other suspended m<strong>at</strong>ter• Vessel made of durable “300 series” stainless steel150B D-ClorReplacementCartridgeP/N 9498-12(12 pack)150G D-ClorReplacementCartridgeP/N 9490-00(12 pack)150GP D-ClorReplacementCartridgeP/N 9492-12(12 pack)150GY D-ClorReplacementCartridgeP/N 9490-12(12 pack)• Designed for use with <strong>all</strong> Everpure D-Clor ® Cartridges• FAA-PMA Approved for quality assuranceINSTALLATION TIPS• To service, simply shut off influent w<strong>at</strong>er supply andunscrew and remove the V-Band Clamp.• After replacing cartridge, air should be released fromthe top vent.• Flush <strong>cartridges</strong> by running w<strong>at</strong>er through <strong>filter</strong><strong>at</strong> full flow <strong>at</strong> the service tap for three minutes, oruntil w<strong>at</strong>er runs clear.OPERATION TIPS• Change <strong>cartridges</strong> as indic<strong>at</strong>ed on the cartridge d<strong>at</strong>asheet.• <strong>Always</strong> <strong>flush</strong> <strong>all</strong> <strong>new</strong> <strong>filter</strong> <strong>cartridges</strong> <strong>at</strong> <strong>time</strong> ofinst<strong>all</strong><strong>at</strong>ion.


SPECIFICATIONSDimensions: 7-3/4”H x 4-15/16”DIncluding V-Band: 5-3/4”DNet weight: 2-1/2 lbs. (1.2 kg) including cartridgeInlet and Outlet Connections: Bottom IN / Bottom OUTTop VentInlet and Outlet: 9/16” 18NF (3/8” tube union)Service flow r<strong>at</strong>e: Minimum .5 gpmMaximum 1.67 gpmWorking pressure: up to 125 psi (8.8 kg/cm 2 ), non-shockMaximum temper<strong>at</strong>ure: 160°F (71°C)No electrical connection requiredPARTS LIST & DIMENSIONSITEMNUMBERDESCRIPTION1 Top, Polished Stainless Steel 0114-002 Gasket (ATA Packaged) 0344-013 Quick-Opening V-Band 0134-004 D-Clor® Cartridge 150G, 150GY150B, 150GP5 Shell, Polished Stainless Steel 0123-00TOPVIEWPARTNUMBERLIMITED WARRANTY OF PHYSICAL QUALITYI f, within eighteen months after manu facture or twe l ve months after purchase (whicheveroccurs first), any part of Everpure, Inc.manufacture which is returned to its factor y, shippingcharges prepaid, is found to be defective in m<strong>at</strong>erial or workmanship in the judgementof Everpure's engineers, Everpure, Inc. will repair or replace such part <strong>at</strong> nocharge, f.o.b., Westmont factory. Everpure, Inc.however, sh<strong>all</strong> not be liable for damagesor delays caused by any defective m<strong>at</strong>erial or workmanship, or by failure of any parts dueto normal wear and t e a r. E ve rp u r e, Inc.will not be responsible for products which malfunctiondue to user neglect or unauthorized modific<strong>at</strong>ion.NOTE:Some st<strong>at</strong>es do not <strong>all</strong>ow limit<strong>at</strong>ions on how long an implied warranty lasts, sothe above limit<strong>at</strong>ion may not apply to yo u .S i m i l a rl y, some st<strong>at</strong>es do not <strong>all</strong>ow the ex c l u-sion or limit<strong>at</strong>ion of consequential or incidental damages, so the above limit<strong>at</strong>ion orexclusion may not apply to you.This warranty gives you specific legal rights and you mayalso have other rights which may vary from st<strong>at</strong>e to st<strong>at</strong>e.SIDEVIEWEVERPURE, INC.660 Blackhawk DriveWestmont, IL 60559-9005Tel (630) 654-4000FAX (630) 654-1115Technical Service(800) 942-1153http://www.everpure.comIn Europe:N . V.EVERPURE (EUROPE) S.A.Research Park, HaasrodeB-3001 HeverleeBelgiumTel 32-16-401191FAX 32-16-402691In Japan:EVERPURE JAPAN,INC.1-8-19, Tsumada Kita,Atsugi-ShiKanagawa 243JapanTel 81-462 (23) 6563FAX 81-462 (21) 6775©2000 Everpure, Inc.Moore Part No. 47350

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!