12.07.2015 Views

nGenius 3900 Series Packet Flow Switch - NetScout

nGenius 3900 Series Packet Flow Switch - NetScout

nGenius 3900 Series Packet Flow Switch - NetScout

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DATA SHEET | <strong>nGenius</strong> <strong>3900</strong> <strong>Series</strong> <strong>Packet</strong> <strong>Flow</strong> <strong>Switch</strong>Network Operations CenterUnified MonitoringFabric Management<strong>nGenius</strong> PFSManagement SoftwareMonitoring ToolsManaged Monitoring Fabric<strong>nGenius</strong> <strong>3900</strong> PFSNetworkingInfrastructureTAPsTAPsNetworkingInfrastructureManagedMonitoringFabric<strong>nGenius</strong><strong>3900</strong> PFS Provider BackboneManagedMonitoringFabric<strong>nGenius</strong><strong>3900</strong> PFS<strong>nGenius</strong> InfiniStreamAppliance<strong>nGenius</strong> InfiniStreamApplianceOther Monitoring ToolsOther Monitoring ToolsPoint of PresencePoint of PresenceFigure 1: <strong>nGenius</strong> PFS Management software delivers unified management of <strong>nGenius</strong> <strong>3900</strong>series switches across the service provider network for streamlining monitoring operations.Granular, Intelligent <strong>Packet</strong>Filtering<strong>nGenius</strong> <strong>3900</strong> series switch providesgranular Layer 2/3/4 intelligent packetfi ltering to enable highly selective packetflow delivery to connected networkmonitoring and security devices. Allfi ltering is performed at wire-speed andis independently defi nable on a per-port-basis. This allows traffi c from a singlenetwork link to be replicated to multipletools with only relevant fl ows sent toeach tool allowing the delivery of the rightinformation to the right tool at the righttime to avoid unnecessary tool load and tomaintain optimal performance.Source Port Tagging<strong>nGenius</strong> <strong>3900</strong> series switch providessource port tagging capability on aper-port basis to allow monitoring toolsto accurately detect the origin of themonitored traffi c, increasing the reliabilityof analysis. When activated, all incomingpackets are tagged to mark the receiveport without affecting packet contentintegrity or causing switch performancedegradations. Source port tags are alsodetected by the <strong>nGenius</strong>ONE Unifi edPerformance Management platform tostreamline and simplify the reporting andvisualization of monitored traffi c.Common Interface ModulesThe <strong>nGenius</strong> <strong>3900</strong> switches leverage aconsistent architectural foundation thatallows common interface modules to beleveraged across the entire chassis series.This allows system architects to bettermanage acquisition cost by investingin a single flexible module that can bedeployed or redeployed across the fullseries of chassis to support small to largesites. This simplifies chassis confi guration,streamlines purchasing requirementsand reduces the cost and complexityassociated with sparing requirements.Interface FlexibilityThe <strong>nGenius</strong> <strong>3900</strong> series interfacemodules are built for deployment versatilityby offering fl exible support for 1, 10, and40 GbE connectivity from a single module.The <strong>nGenius</strong> <strong>3900</strong> series interface modulefeatures FlexPorts that support multispeedoperation for complete deploymentfl exibility. Each module contains 32FlexPorts that can be activated as 1 GbEconnections using SFP transceivers,or 10 GbE connections using SFP+transceivers. Another additional groupof specialized high-speed FlexPorts+support either 4 Ports of 40 GbE or 16ports of 10 GbE using a QSFP breakoutcable. Medium type and speed of eachport can be defi ned manually or may beauto-confi gured through detection of theconnected transceiver module.<strong>nGenius</strong> <strong>3900</strong> series interface modulescan support the following confi gurationcombinations:• 48 x 1 GbE ports• 48 x 1/10 GbE FlexPorts• 32 x 10/1 GbE FlexPorts and4 x 40 GbESERVICE PROVIDER3


DATA SHEET | <strong>nGenius</strong> <strong>3900</strong> <strong>Series</strong> <strong>Packet</strong> <strong>Flow</strong> <strong>Switch</strong>Figure 2: Topology management in <strong>nGenius</strong> PFS Management softwarefacilitates large-scale, end-to-end, drag-and-drop provisioning.Pay-As-You-Grow FlexibilityBy virtue of their modular design anddistributed switching architecture, <strong>nGenius</strong>3903 and 3912 switches allow systemarchitects a high degree of fl exibility toincrementally increase performance andport capacity by deploying additionalinterface modules in the chassis. Thisenables capacity scaling to match thegrowth in attached tools and monitorednetwork links at each location. Furtherconfi guration fl exibility is enabled throughsoftware-based port activation licensing.This enables the deployment of a fullcapacityhigh-density interface module,but only activating a limited numberof ports to meet specifi c deploymentneeds. This result is greater deploymenteffi ciency through a fl exible user-defi nablepay as you grow deployment model. Withthis approach, all hardware needed tosupport full capacity is in place from dayone,and additional ports can be activatedas required.Licensed port-based confi gurationsUnified, Large-Scale SystemManagement and ProvisioningBrowser-based integrated managementand provisioning of the <strong>nGenius</strong> <strong>3900</strong>series packet flow switch supportssingle switch deployments. The optional<strong>nGenius</strong> PFS Management softwareprovides end-to-end unified managementand provisioning of the <strong>nGenius</strong> <strong>3900</strong>series switch, enabling administratorsto rapidly build, store, schedule, andexecute configuration changes andsoftware updates across all deployedswitches regardless of their location. Theunified management platform is idealfor controlling multi-switch monitoringfabrics comprised of hundreds, growingto thousands of ports across differentgeographic locations. Automatedprovisioning allows administrators toidentify the specific end-points of a neededconnection, and the management systemautomatically performs cross-chassisprovisioning defining bandwidth guaranteesas needed. Multi-switch administrationenables the configuration of packet-flowfilters, port speeds, and other configurationparameters, and provides status monitoringfor all switches in the fabric. <strong>nGenius</strong> PFSManagement software supports an optionalstandby server for redundant operations.The active and standby servers are statesynchronized allowing hitless failoverto the standby server without loss ofconfiguration.Anywhere access to the <strong>nGenius</strong> PFSManagement software is supported througha standard web browser. Whether usingthe local management access of switch orthe <strong>nGenius</strong> PFS Management software,secure system access provides userauthentication and supports multiple teamswith role-based access and user-basedactivity logging. The flexible role-basedcontrol allows different operational groupsto each independently access and controlconnections related to their tools withoutaffecting other teams, thereby improvingteam efficiency and collaboration.48 x 1 GbE ports active Upgrade 48 x 1 GbE ports to 48 x 1/10 GbE ports in16-port increments, and add 40 GbE ports in 2-portincrements16 x 1/10GbE ports active Expandable to 48-ports of 10 GbE in 16 port increments,and add 40 GbE ports in 2-port increments32 x 1/10 GbE and 4 x 40 GbE ports active Can use the 4 active 40 GbE ports as 16 ports of 10 GbE(full module capacity)SERVICE PROVIDER4


DATA SHEET | <strong>nGenius</strong> <strong>3900</strong> <strong>Series</strong> <strong>Packet</strong> <strong>Flow</strong> <strong>Switch</strong>MonitoringToolsManagedMonitoringFabric<strong>nGenius</strong> <strong>3900</strong> PFSNode BTAPTAPService EnablersAAA, DNS,...UMTS RANRNCSGSN GGSN Application ServersUMTS <strong>Packet</strong> CoreData CentereNode BTAPTAPSGWPGWIP Backbone & InternetLTE RANLTE <strong>Packet</strong> CoreFigure 3: Examples of deploying <strong>nGenius</strong> <strong>3900</strong> series packet flow switch in a mobileservice provider environment to enable scalable, end-to-end service monitoring.Integrated with the <strong>nGenius</strong>ONEPlatformIntegration of the <strong>nGenius</strong> <strong>3900</strong> seriesswitch with the <strong>nGenius</strong>ONE platformstreamlines diverse administrative tasks.Administrators can use the <strong>nGenius</strong>ONEplatform to view their install base of<strong>nGenius</strong> <strong>3900</strong> switches, track switchcritical alarms, and verify switch integrity.The <strong>nGenius</strong> <strong>3900</strong> series switch can alsoprovide valuable traffi c statistics to the<strong>nGenius</strong>ONE platform, thereby providinginsights into the load within the monitoringinfrastructure, and enabling administratorsto perform proactive load optimization andcapacity planning to avoid monitoring tooloverload. The <strong>nGenius</strong>ONE platform alsoprovides integrated access to the <strong>nGenius</strong>PFS Management software for an effi cient,streamlined administrative workfl ow.Deployment ScenariosFor both wireline and wireless serviceproviders, <strong>nGenius</strong> <strong>3900</strong> series packetfl ow switch provides a scalable solutionfor attaching network monitoring tools atdiverse locations from the access networkthroughout the backbone and to thedata center. The availability of differentchassis densities coupled with granularport licensing enables cost optimizationby matching chassis confi guration tothe immediate requirements and growthoutlook at each network location.Interface fl exibility combined withintelligent Layer 2/3/4 switching andfi ltering capabilities enable optimized traffi cdelivery to the attached tools. This allowstraffi c fl ows from multiple 1 GbE links tobe aggregated and delivered to a highperformance 10 GbE tool. Alternatively,traffi c fl ows from high volume 10 GbEand 40 GbE links can be distributedto multiple 1 GbE and 10 GbE tools tomaintain optimal load balancing , extendtool longevity and increase link accessresiliency.SERVICE PROVIDER5


DATA SHEET | <strong>nGenius</strong> <strong>3900</strong> <strong>Series</strong> <strong>Packet</strong> <strong>Flow</strong> <strong>Switch</strong>SpecificationsFunctional and Capacity Specifi cations3901 3903 3912*Slots 1 3 12Max. 10 GbE/1 GbE Ports 48 144 576Max. 40 GbE Ports 4 12 48Aggregate <strong>Switch</strong>ing Capacity720 Gbps full-duplex(1.4 Tbps aggregate)2.1 Tbps full-duplex(4.2 Tbps aggregate)8.6 Tbps full-duplex(17.2 Tbps aggregate)Console Ports 1 x Serial (RJ45) 1-2 x Serial (RJ45)Management Ports 1 x 10/100/1000Base-T (RJ45) 1-2 x 10/100/1000Base-T (RJ45)Power Supply TypeInternal, hot swappablePower Supply Redundancy 1+1Air <strong>Flow</strong> Side to side Side to side Bottom to topPhysical, Environmental, and Power Specifi cations3901 3903 3912*Height (RU) 1 3 16Mounting BracketsIncludedDimensions19" W x 1.75" H x 19.7" D (in)48.26 W x 4.44 H x 50.16 D (cm)19" W x 5.25" H x 23.25" D (in)48.26 W x 13.34 H x 59.06 D (cm)19" W x 28" H x 27" D (in)48.26 W x 71.12 H x 68.58 D (cm)Weight - No Interface ModulesFully LoadedOperating TemperatureStorage TemperatureOperating Relative HumidityStorage Relative HumidityMax. AC Power Consumption (W)14.8 lb (6.7 kg)21.8 lb (9.9 kg)110 VAC: 380 W33.5 lb (15.2 kg)54.5 lb (24.7 kg)39°F - 104°F (4°C - 40°C)-40°F - 140°F (-40°C - 60°C)20% - 85%, non-condensing20% - 85%, non-condensing110 VAC: 1000 W220 VAC: 1000 W230 lb (104.3 kg)330.8 lb (150 kg)220 VAC: 4850 WMax. DC Power Consumption (W) -42 to -72 VDC: 380 W -42 to -72 VDC: 1000 W -Max. Thermal Output for AC (Btu/h) 1297 3412 16549Max. Thermal Output for DC (Btu/h) 1297 3412 -Regulatory Agency ApprovalsUL60950-1 (USA), CAN/CSA C22.2-60950-1-03 (Canada), IEC60950 3rd Edition (EU)FCC Part 15B Class A, CSA Part 15 Class A, ICES-003 Class A (Canada), EN 55022 Class A (EU),EN 61000-3-3, EN 61000-3-2 EN 55024 (supersedes IEC 61000-4-2, -3, -4, -5, -6, and -11)FCC Part 15, UL (United States), CUL (Canada), CE* 3912 chassis expected to ship in volume in 1HCY14.For more information, please visitwww.netscout.com or contact <strong>NetScout</strong>at 800-309-4804 or +1 978-614-4000Americas East310 Littleton RoadWestford, MA 01886-4105Phone: 978-614-4000Toll Free: 800-357-7666Americas West178 E. Tasman DriveSan Jose, CA 95134Phone: 408-571-5000<strong>NetScout</strong> offers sales, support, and services in over 32 countries.Asia Pacific17F/BNo. 167 Tun Hwa N. RoadTaipei 105, TaiwanPhone: +886 2 2717 1999EuropeOne Canada Square29th fl oor, Canary WharfLondon E14 5DY, United KingdomPhone: +44 207 712 1672Copyright © 2013-2014 <strong>NetScout</strong> Systems, Inc. All rights reserved. <strong>NetScout</strong>, <strong>nGenius</strong> and InfiniStream are registered trademarks, <strong>nGenius</strong>ONE is a trademark of <strong>NetScout</strong>Systems, Inc. and/or its affiliates in the United States and/or other countries. All other brands and product names, and registered and unregistered trademarks are the soleproperty of their respective owners. <strong>NetScout</strong> reserves the right, at its sole discretion, to make changes at any time in its technical information, specifications, and service andsupport programs.SPDS_008-14 02/2014

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!