12.07.2015 Views

Manual - Pine Tree Stove Shoppe

Manual - Pine Tree Stove Shoppe

Manual - Pine Tree Stove Shoppe

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

82.5 RATING PLATE LOCATIONFor rating plate location,see “INSTALLATIONOVERVIEW”LISTED SOLID FUEL BURNING SPACE HEATER /POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉTESTED TO: / TESTÉ SELON : UL1482 / ULC S627 / CSA B366.2 (DEC 92)MODEL / MODÈLE - EPA 14001400 1400L 1402 1450 1400CThis illustration is for referenceonly. Refer to the ratingplate on the appliancefor accurate information.INSTALL AND USE ONLY INACCORDANCE WITH THEMANUFACTURER’SINSTRUCTIONS AND LOCALBUILDING CODES.MINIMUM CEILING HEIGHT:7FT (2.13m)HEARTH EXTENSION /COMBUSTIBLE FLOORPROTECTION: IF INSTALLEDON A COMBUSTIBLE FLOOR,UNIT MUST BE PLACED ON ANON-COMBUSTIBLE FLOORPROTECTOR EXTENDING 18”(455mm) IN FRONT AND 8”(205mm) TO THE SIDES ANDBACK.CHIMNEY TYPE: MINIMUM 6”(152mm) DIAMETERAPPROVED RESIDENTIALTYPE FOR MOBILE HOMEUSE A CHIMNEY LISTED TOULC S629 IN CANADA OR UL103HT IN THE USA.CHIMNEY CONNECTOR: 6”(152mm) DIAMETER MINIMUM24 GAUGE STEEL MINIMUMCLEARANCE FROMHORIZONTAL CONNECTORAND CEILING 18” (455mm).DO NOT OBSTRUCT SPACEUNDER HEATER.SPECIAL METHODS AREREQUIRED WHEN PASSING ACHIMNEY THROUGH A WALLOR CEILING. SEE INSTRUC-TIONS AND BUILDINGCODES.DO NOT CONNECT THIS UNITTO A CHIMNEY FLUESERVING ANOTHERAPPLIANCE.FUEL: FOR USE WITH WOODONLY. DO NOT USE GRATEOR ELEVATE FIRE. BUILDWOOD FIRE DIRECTLY ONHEARTH.WARNING: RISK OF SMOKESPILLAGE. OPERATE E ONLYWITH DOOR FULLY CLOSED.REPLACE GLASS ONLY WITHCERAMIC GLASS.DO NOT OVERFIRE. IFHEATER OR CHIMNEYCONNECTORS GLOW, YOUARE OVERFIRING. INSPECTAND CLEAN CHIMNEYFREQUENTLY. UNDERCERTAIN CONDITIONS OF USECREOSOTE BUILD-UP MAYOCCUR RAPIDLY.OPTIONAL BLOWER KIT:EP-62, 115V, 60HZ, 0.82AMP.ROUTE CORD AWAY FROMUNIT.DANGER: RISK OFELECTRICAL SHOCK.DISCONNECT POWERBEFORE SERVICING UNIT.INSERT: INSTALL AND USEONLY IN SOLID FUELBURNING FIREPLACES. DONOT REMOVE BRICKS ORMORTAR FROM SOLID FUELBURNING FIREPLACE.INSTALL WITH A POSITIVEFLUE CONNECTOR ANDFACEPLATE.POUR INSTALLATION ETUTILISATION CONFORMÉMENTAUX INSTRUCTIONS DUFABRICANT ET AUX CODESLOCAUX DU BÂTIMENT.HAUTEUR DE PLAFOND MINIMAL7PI (2,13m).PROLONGEMENTD’ÂTRE/PROTECTION DUPLANCHER COMBUSTIBLE: SIINSTALLÉ SUR UN PLANCHERCOMBUSTIBLE, L’APPAREIL DOITÊTRE PLACÉ SUR UNE PLAQUEPROTECTRICE INCOMBUSTIBLES’ÉTENDANT SUR 18” (455mm) ÀL’AVANT ET 8” (205mm) À L’ARRIÈREET SUR LES CÔTÉS.TYPE DE CHIMNÉE: DIAMÈTREMINIMAL DE 6” (152mm)APPROUVÉE POUR USAGERÉSIDENTIEL. MAISON MOBILEEMPLOYEZ UNE CHEMINÉEHOMOLOGUÉE ULC S629 AUCANADA OU UL 103HT AUXÉTATS-UNIS.RACCORD DE CHEMINÉE:DIAMÈTRE DE 6” (152mm) D’ACIERDE CALIBRE 24 MINIMUM. 18”(455mm) DE DÉGAGEMENTMINIMAL ENTRE LE RACCORDHORIZONTAL ET LE PLAFOND.NE RIEN ENTREPOSER SOUSL’APPAREIL.CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS ANDINSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USEIN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT). AMINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY BEREQUIRED BY THE AUTHORITY HAVING JURISDICTION.RENSEIGNEZ-VOUS AUPRÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DUSERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONSD’INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTREINSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNEPRISE D’AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm)JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANTJURIDICTION.BACK WALL (M/A)BACK WALL (M/A)8"B"B45°8" 8"A"AC18"LEALCOVESIDE WALL (M/L)IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLEFLOOR, IT MUST BEPLACED ON AN APPROVED PROVED NON-COMBUSTIBLE HEARTH PAD, THATEXTENDS 8” (200mm) 0mm) BEYOND THE STOVE SIDESAND BACK, AND 18”(455mm) TO THE FRONT.SI LE POÊLE EST INSTALLÉ SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉSUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSERLES CÔTÉS ET L’AMÉRE DU POÊLE DE 8” (200mm) ET SE PROLONGER DE 18”(455mm) SUR LE DEVANT.MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALLCHIMNEY CONNECTOR /DÉGAGEMENTS MINIMAUX AUX MATÉRIAUXCOMBUSTIBLES AVEC RACCORDDE CHEMINÉE À PAROI SIMPLE:FROM HEATER / DU POÊLERESIDENTIAL / RÉSIDENTIELDES MÉTHODES SPÉCIALES SONT1400REQUISES LORSQU’UNE12IN/PO (305 mm)CHEMINÉE TRAVERSE UN MUR OU12IN/PO (305 mm)UN PLAFOND. VOIR LES6IN/PO (150 mm)INSTRUCTIONS S ET LES CODES DUBÂTIMENT.USING DOUBLE WALL CONNECTOR/UTILISATIONNE PAS RACCORDER À LAD’UN CONDUIT DE RACCORDEMENT À MAISON / MOBILE HOME*CHEMINÉE E D’UN AUTRE APPAREIL.DOUBLE PAROICOMBUSTIBLE: BLE: POUR USAGE1400 1400AVEC LE BOIS SEULEMENT.10IN/PO (254 mm)10IN/PO (254 mm)N’UTILISEZ PAS DE CHENET OU NE6IN/PO (152 mm)6IN/PO (152 mm)SURÉLEVEZ PAS LE BOIS.4IN/PO (102 mm)4IN/PO (102 mm)PRÉPAREZ LE FEU DIRECTEMENT*MODEL 1400 MAY MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITEDSUR L’ÂTRE.STATES ONLY.AVERTISSEMENT:RISQUED’ÉCHAPPEMENT DE FUMÉE. *LE MODÈLE 1400 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISONTENIR LA PORTE FERMÉEMOBILE AUX ÉTATS-UNIS SEULEMENT.LORSQUE LE POÊLE FONCTIONNE.REMPLACEZ LA VITRE PAR UNEVITRE EN CÉRAMIQUE SEULEMENT.NE SURCHAUFFEZ PASL’APPAREIL. SI L’APPAREIL OU LES LISTED SOLID FUEL BURNING FIREPLACE INSERT /RACCORDS ROUGEOIENT,L’APPAREIL SURCHAUFEE.ENCASTRÉ À COMBUSTIBLE SOLIDE HOMOLOGUÉINSPECTEZ ET NETTOYEZ LA TESTED TO / TESTÉ SELON :CHEMINÉE FRÉQUEMMENT. DANS ULC S628 / UL 1482EPI 1402CERTAINES CONDITIONS, DESDÉPÔTS DE CRÉOSOTE PEUVENTSE FORMER RAPIDEMENT.CEILING / PLAFONDSOUFFLERIE OPTIONNELLE:CLEARANCES TO COMBUSTIBLE CONSTRUCTION /EP-62, 115V, 60HZ, 0,82A. TENEZ LE DDÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:B CCORDON ÉLECTRIQUE LOIN DE(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)L’APPAREIL.AA SIDE FACING / CÔTÉ1 IN/PO (25mm)*DANGER: RISQUE DE SECOUSSEFLOOR / PLANCHER B TOP FACING / DESSUS28 IN/PO (710mm)ÉLECTRIQUE. DÉBRANCHEZ AVANTC MANTEL / TABLETTE28 IN/PO (710mm)DE PROCÉDER À L’ENTRETIEN.D SIDE WALL / MUR LATÉRAL 17 IN/PO (430mm)ENCASTRÉ: INSTALLEZ ET UTILISEZSEULEMENT DANS UN FOYER À*CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AUCOMBUSTIBLE SOLIDE. NEBORD DE LA FAÇADERETIREZ PAS DE MORTIER, NIBRIQUES DU FOYER À COMBUS-TIBLE SOLIDE.INSTALLEZ AVEC UNE GAINECONFORME ET UNE PLAQUE DERECOUVREMENT.CAUTION:HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSESKIN BURNS.QUAND L’APPAREIL FONCTIONNE, L A SURFACE DEVIENTATTENTION: CHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LESVÊTEMENTS T ET LES MEUBLES À L’ÉCART. LE CONTACT PEUTCAUSER DES BRÛLURES À LA PEAU.U.S. ENVIRONMENTAL PROTECTION AGENCY Certifié conforme à la norme d’émanation de particules de juillet 1992.WOLF STEEL LTD.24 Napoleon Rd. Barrie, Ontario L4M 4Y8 CanadaWOLF STEEL USA103 Miller Drive, Crittenden, Kentucky, USA, 410301400 SERIES RATING PLATE ILLUSTRATEDSAMPLEAMPLE MD’UMEPA1400SIDE WALL (M/L)LEB"EDATE CODE / DE DATEW385-0401 / GW415-0762 / B / 11.12.10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!