103.4 FLOOR PROTECTIONIf the appliance is to be installed on top of a combustible fl oor, it must be placed on an approved non-combustiblehearth pad, that extends 8” beyond the appliance sides and back and 18” to the front. The reduced clearancefrom the back of the appliance may result in the appliance pad terminating shorter than 8” beyond theappliance.JKIJMINIMUM FLOOR PROTECTIONFRONT (I) SIDES (J) BACK (K)CANADA 18” 8” 8”USA 16” 8” 8”NOTE: If a section of horizontal chimney connector is used, floor protection isrequired under the chimney connector and 2” beyond each side.3.5 OUTSIDE AIR! WARNINGIF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONGEXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING APPLI-ANCE COULD BE DRAWN INTO THE ROOM.The following are signs that a outside air kit may be required:• When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and yourchimney does not draw steadily.• In the winter there is too much condensation on the windows.• Opening a window seems to alleviate the above symptoms.• A ventilation system is installed in the house.• Other devices are present that exhaust house air.• The house has tight fi tting windows and/or is equipped with a well-sealed vapour barrier.A. Connection from the appliance’s air intake to the outside ismandatory in mobile homes only, either through a hole in thewall or through the hole in the fl oor to line up with the knock outin the leg model or the hole in the pedestal base.B. Use a fresh air kit. Secure the aluminum liner by fl aring the endonce it is inserted through the hole in the base of the leg orpedestal model. If the air intake is through the fl oor, the hole inthe pedestal back must be covered with sheet metal to avoidcold air spillage into the room. A cover plate is available fromyour Wolf Steel Ltd. dealer. Avoid cutting away fl oor joists, wallstuds, electrical wires or plumbing. Seal around the outside pipewith insulation to prevent drafts.C. Attach the rear knockout plate (located inside the ash pan forshipping purposes).W415-0762 / B / 11.12.10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!