12.07.2015 Views

The SSR 50-100HP/37-75 kW Compressor

The SSR 50-100HP/37-75 kW Compressor

The SSR 50-100HP/37-75 kW Compressor

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>SSR</strong> <strong>50</strong>-<strong>100HP</strong>/<strong>37</strong>-<strong>75</strong> <strong>kW</strong>Looking for a rugged, reliable and energy efficientair compressor? <strong>The</strong> Ingersoll-Rand<strong>SSR</strong> is for you. With our integral gear drivesystem, 8000-hour coolant, and leak-freedesign you can count on the <strong>SSR</strong> for years tocome.If your business demands any of these thencheck out the <strong>SSR</strong>.✔Reliability✔Efficiency✔Ease of installation ✔Quiet operation✔ Accurate information ✔Flexible options✔Easy and low cost of maintenance<strong>The</strong>re’s more to the picture<strong>The</strong>re is more to the picture. Providing airsolutions is our specialty. We offer compressedair audits, system design assistance,and other services and products that maximizethe efficiency of your entire plant air system.LINK 1 – Air <strong>Compressor</strong>: An air compressoris the first link in a chain that acts as adependable supply of air to your plant.Shouldn’t the strength of the other links matter?LINK 2 – System components: We offer acomplete lineup of compressed air dryers, filters,Simplair distribution pipework and otheraccessories that work seamlessly with your<strong>SSR</strong> rotary compressor to provide the airquantity and quality you need.LINK 3 – Service providers: <strong>The</strong> backboneof our businessis thequality ofyour serviceprovider.Factory certificationtoservice <strong>SSR</strong>sis a rigorousprocessunmatched inthe industry. Our worldwide distribution networkknows what to do and how to do it.LINK 4 – Manufacturer: Ingersoll-Rand isthe compressed air solutions global leaderwith well over 100 years of experience in themanufacture of compressed air products.We’ve earned our market-leadingposition through our commitmentto the highest levels ofcustomer service andproduct performance,reliability and quality.2


Intellisys ® – Total control at your fingertips.<strong>The</strong> <strong>SSR</strong> comes standard with the Intellisyscontroller–the most advanced active microprocessoravailable on any compressor. Firstbuilt into <strong>SSR</strong>s in the late 1980s, Intellisyshas been updated to employ the latest technology,increasing the reliability while keepingit simple.Simple use – You don’t need to be a computerguru or symbol reader to use the Intellisyscontroller. Information is displayed in clear,plain text and not in codes. Adjustments areeasily made through the finger touch controlpanel and there are no pressure switches todrift or adjust.More information, more accurate –Intellisys constantly monitors and displaysexactly what’s happening in your <strong>SSR</strong> anddisplays it on the face panel. That same informationcan be sent via modem to your serviceprovider for trending or it can be sent in amodbus protocol to your building control system.Time saving diagnostics – <strong>The</strong> Intellisysmonitors 11 key internal functions of the<strong>SSR</strong>. If any of those deviate from its preprogrammedlimit, the controller will automaticallywarn and, if required, shutdown the compressor.<strong>The</strong> display then indicates the problemand the sequence of events leading tothe shutdown. This feature reduces costlytroubleshooting and minimizes downtime.Since Intellisys remembers what alloperating parameters wereprior to shutdown, therestarting processis a snap.AGMA 11 gears withpermanent alignmentClass F insulation with a Class B RiseOversized motor bearings and allcopper windings5


Ultracoolant – Let <strong>The</strong> Fluid Run ItsCourse! You’ll be surprised by the advantagesof using UltraCoolant. First,UltraCoolant has a 2-year/8000 hour life.<strong>The</strong> coolant is changed less often, keepingmaintenance costs to a minimum. Secondly,since UltraCoolant was designed specificallyfor rotary compressors, it assures uninterruptedservice by lubricating, sealing, and coolingunder all normal operating conditions. Third,UltraCoolant’s superior separating propertiescombined with our patented separator systemmeans less coolant is passed downstream toyour plant’s processes. Lower coolant carryoverequals less cost for coolant make-up.Finally, UltraCoolant’s lack of hydrocarbonseliminates the chance of varnish formation.Varnish shortens separator life, coats rotors,bearings and heat exchangers (raising operatingtemperatures) and reduces airend reliability.Patented Separator Design –Our patented two stage conicalbaffle separator minimizescoolant carryover to yourplantand reduces the amountof make-up replaced. Thisdesign also reduces theimpact that overfilling orunderfilling can have oncoolant carryover.InherentLeak Free Design –Lubricant on the floordoesn’t do the compressormuch goodand can create an unsightly mess. By reducingthe number of fittings and using SAE O-ring fittings on all connections larger than1/4" (6 mm), we’ve significantly reduced thepotential leakage problem associated withconventional threaded connections and pipingschemes.Options and AccessoriesUpper range modulation with AutomaticControl Selector – For those plants wherethe demand profile is high or storage is minimal,upper range modulation stabilizes plantair pressure, reducing cycling of componentswith a minimalpower penalty.Automatic ControlSelector uses theIntellisys’ built inintelligence tomonitor air consumptionandchoose theappropriate controlmode.% FULL LOADHORSEPOWER10070<strong>50</strong>20STRAIGHT MODULATIONCONTROLENERGYSAVINGSI-R INTELLISYS®CONTROL00 20 40 60 80 100% CAPACITYStar Delta Starting – A motor requires600% of its full load amps to start. With stardelta starting, the current used to start is only200%, resulting in a cushioned start for bothmechanical and electrical components (standardon <strong>50</strong>Hz units).Power outage restart – If a power failureoccurs, your air compressor automaticallyrestarts after incoming power is restored.Restarting occurs only after an alarm hornsounds.6


Remote start/stop – This option gives youoffsite on/off control.Phase monitor – This option protectsagainst phase loss (single phasing), phasereversal, or low voltage (brownout).TEFC motors – While ODP motors run cooler,not every application is clean and dry. Fordirty and wet applications, TEFC motors areavailable (standard on <strong>50</strong>Hz units).Premium efficient motors – This option lowersoperating costs by maximizing main motorefficiency.Outdoor modification – Outdoor modificationincludes NEMA 4 option and moves thepackage discharge from the topof the package to the side.Heavy Duty filter – <strong>The</strong> heavy duty air filteris designed for applications where the heavydust load would cause the air filter to plugearly.Alternate coolants – H1F food gradeor diester-based <strong>SSR</strong> coolant are available.60Hz <strong>SSR</strong> <strong>50</strong>-<strong>100HP</strong> PerformanceFree Air Delivery - CFM(1) FAD (Free Air Delivery) CFM and M 3 /Min. are ratings of full package performance in accordancewith CAGI-PNEUROP acceptance test standard PN2CPTC2 or ISO1217: 1996 Annex C.Condensate Separator System (CSS) –Provides clean water disposal with minimaloperating costs.Intellisys System Controller (ISC) –Maintains system pressure while minimizingoperating costs.NEMA 4 – For those applications wherethe compressor will be exposed to water.Low ambient – Low ambient packaging isavailable for applications where ambient temperaturesdrop to levels between -10 to35°F/-23 to 2°C. More than heat tracing andspace heaters, this option controls internalpackage temperature at start up protectingthe coolers and the airend as well as maintainingthe motor and starter temperatures.Watercooled – <strong>SSR</strong>s can be outfitted witha variety of watercooled heat exchangers.<strong>The</strong> standard cooler is admiralty brass withoptions existing for 90/10 copper nickel,70/30 copper nickel and stainless steel.Variable Frequency Drive – Offers constantpressure control with maximum energy savings.Nominal HP Model XF Model EP Model HP Model XP L W H Weight Discharge100 psig 125 psig 140 psig 165 psig (in) (in) (in) (lbs) (NPT)<strong>50</strong> 229 211 203 – 67 63 67 2000 1.560 269 246 236 – 67 63 67 2100 1.5<strong>75</strong> 386 332 299 248 67 63 67 2800 1.5100 495 446 412 358 67 63 67 2900 2.0<strong>50</strong>Hz <strong>SSR</strong> <strong>37</strong>-<strong>75</strong><strong>kW</strong> PerformanceFree Air Delivery - M 3 /min.Nominal <strong>kW</strong> Model MLD Model MMD Model MHD Model MJD L W H Weight Discharge7.5 barg 8.5 barg 10 barg 11.4 barg (mm) (mm) (mm) (kg) (NPT)<strong>37</strong> 6.3 6.0 5.6 – 1689 1605 1696 907 1.545 7.4 7.1 6.5 – 1689 1605 1696 953 1.555 10.2 9.2 8.5 7.6 1689 1605 1696 1270 1.5<strong>75</strong> 13.0 12.2 11.0 10.1 1689 1605 1696 1315 2.07


More Than Air. Answers.Online answers: http://www.air.ingersoll-rand.comREGISTERQUALITY ASSURANCELLOYD’S•I S O 9 0 01Ingersoll-Rand air compressors are not designed, intended or approved for breathing air. Compressed air should not be usedfor breathing air applications unless treated in accordance with all applicable codes and regulations.Nothing contained in this brochure is intended to extend any warranty or representation, expressed or implied, regardingthe products described herein. Any such warranties or other terms and conditions of sale shall be in accordance withIngersoll-Rand’s standard terms and conditions of sale for such products which are available upon request.Product improvement is a continuing goal at Ingersoll-Rand. Designs and specifications are subject to change withoutnotice or obligation.Ingersoll-Rand CompanyAir SolutionsP.O. Box 1840800-D Beaty StreetDavidson, NC 28036© 2001 Ingersoll-Rand Company Form 3167-B Printed in USA