ENCELIUM Networkwww.sylvania.com/enceliumENCELIUM ® <strong>Energy</strong> Management System – Hardware<strong>Energy</strong> <strong>Control</strong> <strong>Unit</strong>ENCELIUM GreenBus II Communication NetworkENCELIUM ® <strong>Energy</strong> Management System ArchitectureLight FixtureENCELIUMGreenBus IILCMOcc.SensorSIMLCMSIMPhoto SensorWall StationFLOOR 2ECUPCS/PCWNetwork SwitchSecure Ethernet(existing)ECUSSUThe <strong>Energy</strong> <strong>Control</strong> <strong>Unit</strong> (ECU)is a rack or wall mounted control device that collects, processes, anddistributes lighting control information to ENCELIUM control modules, wallcontrollers, and other devices over the ENCELIUM Greenbus II network.Each ECU features 8 GreenBus II communication channels and typicallycontrols 100 nodes per channel (8 x 100 = 800 nodes in total).The ECU is the central intelligence point in the system. It collects signalinformation from photo sensors (light levels), occupancy sensors(occupancy status) and wall mounted lighting controllers. It thendetermines appropriate brightness levels or ON/OFF status for eachfixture and zone. Photo sensors do not directly control light levels butrather are connected to the ENCELIUM GreenBus II network and providelight level information to the ECU. The ECU then determines what actionto take based on the status signals from the sensors.Each ECU has two Ethernet connections. One connection is forcommunication with other ECUs and the SSU on the ENCELIUM Network.The second ethernet connection can be used for communication witha facility’s or tenant Local Area Network (LAN) to allow secureFLOOR 1ENCELIUM Polaris 3DSystem ArchitectureThis illustration shows how each component is easily integrated into the ENCELIUM <strong>Energy</strong>Management System (EMS). ENCELIUM GreenBus II is a two-wire communication topology forsupplying data and power to the system. Each light fixture, sensor, and wall controller is daisychainedback to the <strong>Energy</strong> <strong>Control</strong> <strong>Unit</strong> (ECU) using pre-terminated ‘click & go’ ENCELIUMGreenBus II communication cabling. ECUs typically control individual floors and are linked viaan Ethernet Network. Internet or LAN connection allows floor plan based control software tobe operated anywhere on the network. For reference, the component shown on this data sheetis highlighted.communication to ENCELIUM equipment for access to the ENCELIUMPolaris 3D or Personal <strong>Control</strong> Software (PCS) applications.ECUs are typically located in the electrical room or communication closet oneach floor of a building and are connected to a network switch using standardEthernet connections.LMS053R2 5-13


Ordering InformationItem # Ordering Description Field Bus Modifiers45243 EN-ECU-8PORT-GB2 GB2 —<strong>Energy</strong> Management System HardwareENCELIUM GreenBus II TM channels, Class IIENCELIUM GreenBus II cable only.Typically 100 nodes per channel.Factory ServiceAC Supply120-240Vac/ \50-60Hz/200WNon-emergencyCONNECTIONSECUENCELIUM GreenBus IIChannel StatusIndicator (1 per channel)Typical wall mounting of ECU with SSU,Ethernet Switch and Power BarEthernet SwitchPower BarSpecifications1.2"(30.48mm)18.9"(480.06mm)SSUENCELIUM Network8.45"(214.63mm)• 8 ENCELIUM GreenBus II ports, Class 2• Tenant LAN Access Port Ethernet – 10/100BaseTx Cat. 5RJ45 port• ENCELIUM <strong>Energy</strong> <strong>Control</strong> Network Port – Ethernet1-/100BaseTx Cat. 5 RJ45 port• Status LED on front of unit• Configuration stored in non-volatile flash memory• 8 Channel communication status LED on back ofthe unit• Weight: 4.25lbs (1.93kg)• Max. ambient temperature +40°C/104°F• For mounting on standard 19" rack (1U width),individual wall mount or optional 4U wall mounted rack• Power Supply: 120-240VAC/50-60Hz/200WTenant LAN accesspoinet Ethernet10/100Base TxENCELIUM Ethernet connections to ECUs,SSU, Ethenert Switch and tenant LAN.To additional ECUsInstall in accordance with all applicable national and local electrical and building codes.OSRAM and Logo are registered trademarks of OSRAM GmbH.ENCELIUM is a registered trademark of OSRAM SYLVANIA Inc.GreenBus II and Polaris 3D are trademarks of OSRAM SYLVANIA Inc.SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA Inc.Specifications subject to change without notice.ECUSSUPower BarEthernet SwitchECU18.9”480.06mmENCELIUM <strong>Energy</strong><strong>Control</strong> NetworkConnectionto tenantLAN• Dimensions: 18.9" W x 1.2" H x 8.45" D(480.06mm W x 30.48mm H x 214.63mm D)• Normal non-emergency circuit only. Do notconnect to UPS or emergency power.• Strand 3 prong AC plus (NEMA 5-15P)• 8 GreenBus II channel parts, 22.5VDC, Class II• cULus Listed– <strong>Energy</strong> Management Equipment (UL 916)– Emergency Lighting Equipment (UL 924)• Complies with the following electromagneticrequirements:– EN 61000-4-2– EN 61000-4-4– EN 61000-4-5• FCC Part 15/ICES-003<strong>Unit</strong>ed StatesOSRAM SYLVANIA100 Endicott StreetDanvers, MA 019231-800-LIGHTBULBTradePhone: 800-255-5042Fax: 800-255-5043National AccountsPhone: 800-562-4671Fax: 800-562-4674OEM/Special MarketsPhone: 800-762-7191Fax: 800-762-7192RetailPhone: 800-842-7010Fax: 800-842-7011SYLVANIA Lighting ServicesPhone: 800-323-0572Fax: 800-537-0784Display/OpticPhone: 888-677-2627Fax: 855-543-1043CanadaOSRAM SYLVANIA LTD.2001 Drew RoadMississauga, ON L5S 1S41-800-LIGHTBULBTradePhone: 800-263-2852Fax: 800-667-6772OEM/Special Markets/Display/OpticPhone: 800-265-2852Fax: 800-667-6772RetailPhone: 800-720-2852Fax: 800-667-6772SYLVANIA Lighting ServicesPhone: 800-663-4268Fax: 866-239-1278MexicoOSRAM MEXICOTultitlan/Edo de MexicoPhone: 011-52-55-58-99-18-50ENCELIUM ® Products<strong>Unit</strong>ed StatesPhone: 201-508-1570Fax: 201-508-1589CanadaPhone: 905-731-7678Fax: 905-731-1401www.sylvania.com/sylvania/sylvaniaPrinted on recycled paper with 50% recycled content including30% Post Consumer Waste and is acid and elemental chlorine free.© 2013 OSRAM SYLVANIA 5-13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!