12.07.2015 Views

protecta iii - Gunneman

protecta iii - Gunneman

protecta iii - Gunneman

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PROTECTA III S/S STAINLESS STEEL26Ex e FLUORESCENTThe Protecta III is also available in a stainless steel body version. This incorporates the same design and monitoringfeatures found in the GRP body Protecta. The increased durability of its stainless steel construction makes thisluminaire ideal for applications where there is a high risk of mechanical damage or exposure to chemical agents.Standard SpecificationFeaturesType of ProtectionATEX ClassificationArea ClassificationCertificateCodingEnclosureReflector/GeartrayEntryTerminationInstallationLampholderControl GearRelampingBurning PositionIngress ProtectionElectrical SupplyBatteryDurationEmergency OutputEx e mb q (Increased safety EncapsulationPowder filling)Group II Category 2 GDZone 1 and Zone 21 areas to EN60079-10-1and EN 60079-10-2 with installation toEN 60079-14EC Type Examination CertificateBaseefa04ATEX0220II 2 GD Ex e mb q IIC T4 Tamb 55°C(45°C for emergency version)Marine grade 316S31 stainless steel body withpolycarbonate coverWhite polyester painted zinc coated steel4 x M20 cable entries, 2 at each endQuick release mains terminals - 3 core 4mm² max.conductor with looping and through wiring facility.4 core 4mm² connectors on emergency).(6mm² terminations available - /SC option)Two M8 tapped stainless steel inserts locatedon rear of bodyG13 (Bi-pin)High FrequencyQuick release diffuser clamps and hinged coverUniversalIP66 to EN 60529220V - 254V 50/60Hz220V - 300V dc (non-emergency only)Internal Ni-Cd (6V)90 minutes to EN60598-2-2250% of one lamp (18W)25% of one lamp (36W)316 Stainless steel body and clamp barAdvanced control gear gives 50/60Hzoperation, high power correction factor andregulated lamp output that is 20% greaterat -20°CAutomatic lamp de-energisationon openingResistance to voltagefluctuationsBattery management, monitoringand automatic self testdc operation(non-emergency only)Ability to detect and indicate impendingend of emergency lamp lifebefore actual failureEnd of life (EOL) protectionto IEC 60079-7(with EOL I and EOL II functionality)International ApprovalsATEX, GB (China), GOST, CSA and CEPELIECEx Compliant

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!